(189IO) MODEL CS7221/CS7231 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 07/11/2012
189A
SAVE THESE INSTRUCTIONS
(Generic layout of an electrical device relative to a swimming pool. Illustration not to scale)
According to the International Standard, IEC 60364-7-702, on electrical installation of swimming pools
and other basins equipments, the following installation distances must be respected:
• The filter pump must be position more than 2m away from the pool walls.
• The power cord plug to the 220-240 volt electrical power source of the filter pump must be position
more than 3.5 m away from the pool walls.
Check your local authorities to determine the appropriate standard and requirements for “electrical
installation of swimming pools and basins equipments”. The following table is for reference only:
English
Page 13
SETUP INSTRUCTIONS
SALTWATER SYSTEM/FILTER PUMP
Saltwater System/Filter Pump
1. Remove the Saltwater System/Filter Pump and hoses from the packaging.
2. Place the Saltwater System/Filter Pump in a location for hose (8) connections to the plunger valve
assemblies.
NOTE: Some regional regulations may require the filter pump to be mounted on a stationary
platform. There are two mounting holes located in the pump base for this reason. Consult
your local authorities for filter pump mounting requirements.
3. Grasp the two pump hoses (8) and connect the hose nuts to the Saltwater System/Filter Pump.
4. In a counter-clockwise motion unscrew the threaded filter housing collar (3) from the filter housing.
Place it in a safe place.
5. The Saltwater System/Filter Pump is an airtight system. In a counter-clockwise motion turn both air
release valves (1 & 7) 1 - 2 turns to open. DO NOT remove air release valves as water will expel
with force if the motor is turned on and injury may occur.
6. Grasp and remove the filter housing cover (4). Check to see if a cartridge is inside the housing. If
yes, replace the cover, finger tighten the housing collar (3) back onto the filter housing.
7. Gently finger tighten the sediment release valve located at the bottom of the housing to be sure that
water does not leak out.
8. When the pool is filled connect the hose from the electrolytic cell outlet to the highest strainer
assembly. You will find the hose connection at the bottom of the plunger valve assembly. Use the
hose nut to attach the hose.
9. Connect the second hose to the middle of the motor housing and to the remaining liner connection.
IMPORTANT
To prevent air lock, open the lower plunger valve (connected inlet hose) first and then the
upper plunger valve (connected outlet hose). Open air release valves, lift and lower the inlet
hose until water starts to flow out of the air release valves, close air release valves.
FILTER PUMP INSTALLATION DISTANCE
International
France
Germany
The Netherlands
Country/Region Standard Number
IEC 60364-7-702
NF C 15-100-7-702
DIN VDE 0100-702
NEN 1010-702
>2m
>3.5m
POOL
hoses Electrical
device