670150
253
Verklein
Vergroot
Pagina terug
1/282
Pagina verder
18-5
D Command table (continued)
18
CONTROL COMMAND
Cmd. Sub Cmd. Data Description
1A
05 0023 0000 to
0255
Send/read CW side tone gain
(0000=0% to 0255=100%)
0024 00 or 01 Send/read CW side tone gain limit
(00=OFF, 01=ON)
0025 00 to 06 Send/read audio output level at APF ON
(00=0 dB, 06=+6 dB)
0026 0000 to
0255
Send/read beep gain
(0000=min. to 0255=max.)
0027 00 or 01 Send/read beep gain limit (00=OFF, 01=ON)
0028 00 to 30 Send/read headphones output ratio for the
volume level (00=–15 dB to 30=+15 dB)
0029 00 or 01 Send/read headphone output selection
(00=separated, 01=mixed)
0030 00 or 01 Send/read AF/SQL signal output to ACC-A
(00=MAIN; 01=SUB)
0031 00 or 01 Send/read AF/SQL signal output to ACC-B
(00=MAIN; 01=SUB)
0032 00 or 01 Send/read AF/IF signal output to ACC-A
(00=AF; 01=IF)
0033 00 or 01 Send/read the band selection for AF/IF signal
output to ACC-A (While holding down [XFC]
during split frequency operation)
(00=Main band, 01=Sub band)
0034 0000 to
0255
Send/read AF output level to ACC-A
(0000=0% to 0255=100%)
0035 00 or 01 Send/read squelch function for the AF signal
output to ACC-A
(00=OFF (Open), 01=ON)
0036 00 or 01 Send/read voice synthesizer and beep output
setting to ACC-A (when audio output is set)
(00=OFF, 01=ON)
0037 0000 to
0255
Send/read IF signal output level to ACC-A
(0000=0%, 0255=100%)
0038 00 or 01 Send/read AF/IF signal output to ACC-B
(00=AF; 01=IF)
0039 00 or 01 Send/read the band selection for AF/IF signal
output to ACC-B (While holding down [XFC]
during split frequency operation)
(00=Main band, 01=Sub band)
0040 0000 to
0255
Send/read AF output level to ACC-B
(0000=0% to 0255=100%)
0041 00 or 01 Send/read squelch function for the AF signal
output to ACC-B
(00=OFF (Open), 01=ON)
0042 00 or 01 Send/read voice synthesizer and beep output
setting to ACC-B (when audio output is set)
(00=OFF, 01=ON)
0043 0000 to
0255
Send/read IF signal output level to ACC-B
(0000=0%, 0255=100%)
0044 00 or 01 Send/read AF/IF signal output to S/P DIF
(00=AF, 01=IF)
0045 00 or 01 Send/read the band selection for AF/IF signal
output to S/P DIF (While holding down [XFC]
during split frequency operation)
(00=Main band, 01=Sub band)
0046 0000 to
0255
Send/read AF output level to S/P DIF
(0000=0% to 0255=100%)
0047 00 or 01 Send/read squelch function for the AF signal
output to S/P DIF
(00=OFF (Open), 01=ON)
0048 00 or 01 Send/read voice synthesizer and beep output
setting to S/P DIF (when audio output is set)
(00=OFF, 01=ON)
0049 0000 to
0255
Send/read IF signal output level to S/P DIF
(0000=0%, 0255=100%)
0050 00 or 01 Send/read AF/IF signal output to USB B
(00=AF, 01=IF)
0051 00 or 01 Send/read the band selection for AF/IF signal
output to USB B (While holding down [XFC]
during split frequency operation)
(00=Main band, 01=Sub band)
0052 0000 to
0255
Send/read AF output level to USB B
(0000=0% to 0255=100%)
Cmd. Sub Cmd. Data Description
1A
05 0053 00 or 01 Send/read squelch function for the AF signal
output to USB B
(00=OFF (Open), 01=ON)
0054 00 or 01 Send/read voice synthesizer and beep output
setting to USB B (when audio output is set)
(00=OFF, 01=ON)
0055 0000 to
0255
Send/read IF signal output level to USB B
(0000=0%, 0255=100%)
0056 00 or 01 Send/read AF/IF signal output to LAN
(00=AF, 01=IF)
0057 00 or 01 Send/read the band selection for AF/IF signal
output to LAN (While holding down [XFC]
during split frequency operation)
(00=Main band, 01=Sub band)
0058 0000 to
0255
Send/read MOD input level from ACC-A
(0000=0% to 0255=100%)
0059 0000 to
0255
Send/read MOD input level from ACC-B
(0000=0% to 0255=100%)
0060 0000 to
0255
Send/read MOD input level from S/P DIF
(0000=0% to 0255=100%)
0061 0000 to
0255
Send/read MOD input level from USB B
(0000=0% to 0255=100%)
0062 0000 to
0255
Send/read MOD input level from LAN
(0000=0% to 0255=100%)
0063 00 to 10 Send/read MOD input connector during
DATA OFF
( 00=MIC, 01=ACC-A, 02=ACC-B, 03=MIC/
ACC-A, 04=MIC/ACC-B, 05=ACC-A/ACC-
B, 06=MIC/ACCA/ACC-B, 07=S/P DIF,
08=USB, 09=LAN, 10=MIC/USB)
0064 00 to 10 Send/read MOD input connector during
DATA1
( 00=MIC, 01=ACC-A, 02=ACC-B, 03=MIC/
ACC-A, 04=MIC/ACC-B, 05=ACC-A/ACC-
B, 06=MIC/ACCA/ACC-B, 07=S/P DIF,
08=USB, 09=LAN, 10=MIC/USB)
0065 00 to 10 Send/read MOD input connector during
DATA2
( 00=MIC, 01=ACC-A, 02=ACC-B, 03=MIC/
ACC-A, 04=MIC/ACC-B, 05=ACC-A/ACC-
B, 06=MIC/ACCA/ACC-B, 07=S/P DIF,
08=USB, 09=LAN, 10=MIC/USB)
0066 00 to 10 Send/read MOD input connector during
DATA3
( 00=MIC, 01=ACC-A, 02=ACC-B, 03=MIC/
ACC-A, 04=MIC/ACC-B, 05=ACC-A/ACC-
B, 06=MIC/ACCA/ACC-B, 07=S/P DIF,
08=USB, 09=LAN, 10=MIC/USB)
0067 00 to 02 Send/read the band selection for operating
frequency band signal output to ACC-A
(00=MAIN, 01=SUB, 02=TX)
0068 00 to 02 Send/read the band selection for operating
frequency band signal output to ACC-B
(00=MAIN, 01=SUB, 02=TX)
0069 00 or 01 Send/read relay type selection
(00=Reed, 01=MOS-FET)
0070 00 to 07 Send/read the Main band’s external meter
output selection
( 00=Auto, 01=S (Main), 02=Po, 03=SWR,
04=ALC, 05=COMP, 06=VD, 07=ID)
0071 00 to 07 Send/read the Sub band’s external meter
output selection
( 00=Auto, 01=S (Sub), 02=Po, 03=SWR,
04=ALC, 05=COMP, 06=VD, 07=ID)
0072 0000 to
0255
Send/read the Main band’s external meter
output level (0000=0% to 0255=100%)
0073 0000 to
0255
Send/read the Sub band’s external meter
output level (0000=0% to 0255=100%)
0074 00 to 02 Send/read reference signal in/out setting
(00=IN, 01=OFF, 02=OUT)
0075 0000 to
0255
Send/read reference signal frequency setting
(0000=0% to 0255=100%)
0076 0000 to
0255
Send/read LCD unit backlight brightness
(0000=0% to 0255=100%)
0077 0000 to
0255
Send/read switch indicator brightness
(0000=1 to 0255=100)
Send/read data
253

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Icom IC7850 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Icom IC7850 in de taal/talen: Engels als bijlage per email.

De handleiding is 15,41 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info