51
9
CONNECTIONS AND MAINTENANCE
DD
Using the optional MB-75
An optional MB-75 FLUSH MOUNT is available for mounting
the transceiver to a flat surface such as an instrument panel.
CAUTION: KEEP the transceiver and microphone at
least 1 meter away from your vessel’s magnetic navigation
compass.
q Using the attached template, carefully cut a hole into the
instrument panel (or wherever you plan to mount the trans-
ceiver).
w Slide the transceiver through the hole as shown below.
e Attach the 2 supplied bolts (M5 × 8 mm) on either side of
the IC-M602.
r Attach the clamps on either side of the IC-M602.
• Make sure that the clamps align parallel to the IC-M602’s body.
t Tighten the end bolts on the clamps (rotate clockwise) so
that the clamps press firmly against the inside of the in-
strument control panel.
y Tighten the locking nuts (rotate counterclockwise) so that
the IC-M602 is securely mounted in position as below.
u Connect the antenna and control cable, then return the in-
strument control panel to its original place.
9