46
7
SCANS
■ Programmed scan operation
Scans specified frequency range, programmed in the
memory channel 1A/1b, 2A/2b and 3A/3b. Before start-
ing the programmed scan, scan edges should be pro-
grammed in these channels.
DD
Selecting scanning range
q Push [M/S•BAND] or [SUB] to select the desired
frequency band to be scanned.
w Push [SET] then [SCAN .] to enter the scan set
mode.
e Push [DN ▼ ] or [▲ UP] to select the programmed
scan item.
•“P-SCAn” is displayed.
r Rotate the tuning dial to select the desired scanning
range from 1A-1b, 2A-2b and 3A-3b.
• Push [M-CL 5] for 1 sec. to return to the default setting.
t Push [SCAN .] to exit from the scan set mode.
DD
Starting the programmed scan
q Push [M/S•BAND] or [SUB] to select the desired
frequency band to be scanned.
w Push [V/M 1] to select VFO mode.
e Select the desired operating mode.
•The operating mode can also be changed while scan-
ning.
r Push [SCAN .] to start the programmed scan.
•“SCAN” indicator flashes.
• The tuning step setting is used for the scanning step.
•1 kHz or 1 MHz tuning step can also be used as the
scanning step.
t Push [SCAN .] to cancel the scan.
If the same frequency is programmed into the scan
edge memory channel 1A and 1b, 2A and 2b or 3A
and 3b, programmed scan does not start.
■ Memory scan operation
Scans programmed memory channels only. Blank
channels and programmed scan edge channels
(1A/1b, 2A/2b and 3A/3b) are not scanned.
q Push [M/S•BAND] or [SUB] to select the desired
frequency band to be scanned.
w Push [V/M 1] to select memory mode.
e Push [SCAN .] to start the memory scan.
•“SCAN” indicator flashes.
• Pushing [SPCH•LOCK] for 1 sec. during scan starts
mode select scan and “LOCK” indicator appears. (p. 47)
r Push [SCAN .] to cancel the scan.