•Command table
00 — Send frequency data
01 Same as Send mode data
command 06
02 — Read band edge frequencies
03 — Read operating frequency
04 — Read operating mode
05 — Set frequency data
06 00 Select LSB
01 Select USB
02 Select AM
03 Select CW
04 Select RTTY
05 Select FM
07 Select CW-R
08 Select RTTY-R
07 — Select VFO mode
B0 Exchange main and sub readouts
B1 Equalize main and sub readouts
C0 Turn the dualwatch OFF
C1 Turn the dualwatch ON
D0 Select main readout
D1 Select sub readout
08 — Select memory mode
0001–0101*
1
Select memory channel
*
1
P1=0100, P2=0101
09 — Memory write
0A — Memory to VFO
0B — Memory clear
0E 00 Scan stop
01 Programmed/memory scan start
02 Programmed scan start
03 ∂F scan start
12 Fine programmed scan start
13 Fine ∂F scan start
22 Memory scan start
23 Select memory scan start
0E A1–A7 Set ∂F scan span (A1=±5 kHz,
A2=±10 kHz, A3=±20 kHz,
A4=±50 kHz, A5=±100 kHz,
A6=±500 kHz, A7=±1 MHz)
B0 Set as non-select channel
B1 Set as select channel
D0 Set scan resume OFF
D3 Set scan resume ON
0F 00 Turn the split function OFF
01 Turn the split function ON
10 00 Select 10 Hz (1 Hz) tuning step
01 Select 100 Hz tuning step
02 Select 1 kHz tuning step
03 Select 5 kHz tuning step
04 Select 9 kHz tuning step
05 Select 10 kHz tuning step
06 Select 12.5 kHz tuning step
07 Select 20 kHz tuning step
08 Select 25 kHz tuning step
11 00 Attenuator OFF
06 Attenuator ON (6 dB)
12 Attenuator ON (12 dB)
18 Attenuator ON (18 dB)
12 00 Select/read antenna selection
01 (00=ANT1, 01=ANT2 : Add 0 or 1
to turn [RX ANT] OFF or ON, re-
spectively.)
13 00 Announce with voice synthesizer
01 (00=all data; 01=frequency and
02 S-meter level; 02=receive mode)
14 01 + Level data [AF] level setting (0=max. CCW to
255=max. CW)
02 + Level data [RF] level setting (0=max. CCW to
255=11 o’clock)
03 + Level data [SQL] level setting (0=11 o’clock to
255=max. CW)
06 + Level data [NR] level setting (0=min. to
255=max.)
07 + Level data Inside [TWIN PBT] setting or IF
shift setting (0=max. CCW,
128=center, 255=max. CW)
08 + Level data Outside [TWIN PBT] setting
(0=max. CCW, 128=center,
255=max. CW)
09 + Level data [CW PITCH] setting (0=low pitch
to 255=high pitch)
0A + Level data [RF POWER] setting (0=mini. to
255=max.)
0B + Level data [MIC GAIN] setting (0=mini. to
255=max.)
0C + Level data [KEY SPEED] setting (0=slow to
255=fast)
0D + Level data [NOTCH] setting (0=low freq. to
255=high freq.)
0E + Level data [COMP] setting (0=mini. to
255=max.)
0F + Level data [BK-IN DELAY] setting (0=short
delay to 255=long delay)
10 + Level data [BAL] level setting (0=max. CCW,
128=center, 255=max. CW)
12 + Level data [NB] level setting (0=mini. to
255=max.)
15 + Level data Monitor gain setting (0=0% to
255=100%)
16 + Level data VOX gain setting (0=0% to
255=100%)
17 + Level data Anti-VOX gain setting (0=0% to
255=100%)
18 + Level data LCD contrast setting (0=0% to
255=100%)
19 + Level data LCD bright setting (0=0% to
255=100%)
15 01 Read squelch condition
02 Read S-meter level
11 Read Po meter level
12 Read SWR meter level
13 Read ALC meter level
14 Read COMP meter level
16 02 Preamp (0=OFF; 1=preamp 1;
2=preamp 2)
12 AGC selection (1=Fast; 2=Mid;
3=Slow)
Command Sub command Description Command Sub command Description
111
16
CONTROL COMMAND