6. Return the dial to the Run position. This is all that
is required for the most basic operations. ACC will
water automatically in any dial position except
OFF”.
7. Test: The Test program will start every station in the
controller sequentially, in numerical order, for the
specified time. The minimum time is one second
for conventional controllers, and 15 seconds for
decoder controllers. The maximum run time in Test
Program is 15 minutes per station. Turn the dial to
the Run position. Test is started by holding down the
Programs button for 3 seconds. Enter the Test time
and wait 5 seconds for the Test cycle to begin. Each
station LED on the output modules will light green
when a station is running, red if a fault is detected.
Decoder controllers cannot show individual station
activity , but the ADM99 lights will show activity on
the Communicating and Module/Line Activity lights
during operations.
Decoder controllers will start all 99 stations in the
test mode. It does not matter how many decoders
are installed in the field, the controller will try to run
all 99 stations. The controller will receive alarms
for any stations that are not present in the field, or
stations that are not assigned to a decoder. When
running the Test Program in a decoder controller,
you can manually end the Test by turning the dial to
Off after the last real” station has run.
Test actually starts stations, and this will cause
actual watering in a fully installed system.
8. Manual Start: Turn the dial to the Manual Operation
dial position to manually start any Program, or
single station. When the display shows Manual
Program, use the Programs button to select the
Program, and turn the dial to the Run position. The
program will start in a few seconds. TIP: You can
also hold down the right arrow button for 3 seconds
to shortcut to Manual starts.
9. To start a Single Station: When Programis
flashing, use the + button to change to Manual One
Station. Use the down arrow to move to the station
number, and +/- to select a station. Use the down
arrow to move to the run time, and +/- to change
the run time (hh:mm:ss format, from 1 second to 6
hours). Turn the dial back to the Run position, and
the station will start within a few seconds.
ConTroller proGrammInG and operaTIon .............................
USING THE INFORMATION BUTTON
The Information button is used to provide programming
tips, summary information and/or to unlock extended
features, depending on the dial position. If a flow meter
is installed, press the Information button (with dial in the
Run position) to see actual flow at any time.
If the backlit display turns off while you are programming
(it will time out after 5 minutes of inactivity), press the
Information button to relight it (to prevent accidental
changing of any settings by pressing the other keys).
Pressing and holding the Information button will change
the screen to either a summary screen of that dial position
or will provide a programming tip. Releasing the button
will return you to the normal programming screen for that
dial position.
Some dial positions have extended features that are
accessible by holding down the Information button, and
then turning the dial to that position.
This will unlock the extended features. Extended
features are features that are protected from accidental
re-programming because they are critical to the proper
operation of the controller. Programming these extended
features is explained in the Extended Features section. The
ACC has the following Extended Features:
No Water Window
Delay between Stations
Making the M/V circuit Normally On (instead of
Normally Off) and M/V circuit location (Controller or
ADM for Decoder controllers)
Setting the Flow Sensor size and type
Set individual station parameters (Flow, Limit, and
Delay) and flow sensor location (Controller or ADM
for ICD-SEN sensor decoder)
Set sensor location: set each sensor to controller,
ADM for for ICD-SEN location, or ET for individual ET
sensors
SSG (Simultaneous Station Group) setup
Custom Manual program setup
Test Program
Easy Retrieve backup
26

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Hunter ACC bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Hunter ACC in de taal/talen: Engels als bijlage per email.

De handleiding is 7,53 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Hunter ACC

Hunter ACC Gebruiksaanwijzing - Deutsch - 108 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info