90
Off Course Alarm
Off Course Alarm sounds when the boat has moved
too far off course based on the menu setting when navigating. Off Course Alarm
allows you to set how far the boat is allowed to move off course before the Off
Course Alarm will sound.
To change the Off Course Alarm setting:
1. Highlight Off Course Alarm on the Alarms main menu.
2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the Off Course Alarm
setting. (Off, 25 to 3000 feet, 10 to 1000 meters [International Models only],
Default = 300 ft, 100 m)
Arrival Alarm
Arrival Alarm sounds when the boat has either
exceeded the distance to the destination waypoint, or has entered the Arrival Alarm
Circle, based on the menu setting when navigating. Arrival Alarm allows you to set how
close the boat must be to the destination waypoint before the Arrival Alarm will sound.
To change the Arrival Alarm setting:
1. Highlight Arrival Alarm on the Alarms main menu.
2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the Arrival Alarm
setting. (Off, 25 to 3000 feet, 10 to 1000 meters [International Models only],
Default = 150 ft, 50 m)
Arrival Alarm Circle
Off Course Limits
89
Low Battery Alarm
Low Battery Alarm sounds when the input battery
voltage is equal to or less than the menu setting. The battery alarm will only sound for
the battery that is connected to the 700 Series™ Fishing System. The Low Battery Alarm
should be set to warn you when the battery voltage drops below the safety margin that
you have determined. For instance, if you are running a trolling motor (battery
operated), you would want to set the Low Battery Alarm to sound before the battery
voltage drops too low for it to be used to start your main, gasoline-powered engine.
To c
hange the Low Battery Alarm setting:
1. Highlight Low Battery Alarm on the Alarms main menu.
2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the Low Battery
Alarm setting. (Off, 8.5V - 13.5V, Default = Off)
Temp Alarm
Temp Alarm sounds when the water temperature
detected by the 700 Series™ reaches the Temp Alarm setting, which is either set in
degrees Fahrenheit or Celsius [International Models only]. For example, if the Temp
Alarm is set to 58 degrees Fahrenheit, and the water temperature falls from 60 degrees
to 58 degrees, the Temp Alarm will sound. Similarly, if the water temperature rises from
56 degrees to 58 degrees, the Temp Alarm will also sound.
To change the Temp Alarm setting:
1. Highlight Temp Alarm on the Alarms main menu.
2. Use the LEFT or RIGHT 4-Way Cursor Control keys to change the Temp Alarm
setting. (Off, 33-120 [Fahrenheit], 0-50 [Celsius], Default = Off)