ENGLISH
5.2.4 Force limit in the CLOSE direction (see figure 29)
In menu 6 the automatic force limit for closing the
door can be altered in the sensitive setting. This is only
necessary for doors which run extremely unevenly. An
unnecessarily high setting should not be selected.
If the closing force is set too high, this can result
in damage to property or injury to persons. In the
case of extremely smooth-running doors, a lower setting
can be selected if the sensitivity to obstructions is to be
increased.
Switch to menu 0 by pressing the PRG button.
5.2.5 Door behaviour before/at the CLOSE travel limit
(see figure 30)
In menu 7 the automatic belt relief and the braking
behaviour at the CLOSE travel limit can be influenced:
Display “Soft“ stop Relief
0 long automatic
1 long without
2 long short
3 * short automatic
4 short without
5 short short
6 without automatic
7 without without
8 without short
Switch to menu 0 by pressing the PRG button.
Note
For up-and-over doors we recommend setting the “soft“
stop at long.
5.2.6 Force limit in the OPEN travel direction (see figure 31)
In menu 8 the automatic power limit for opening the
door can be altered in the sensitive setting. This is only
necessary for doors which run extremely unevenly.
An unnecessarily high setting should not be selec-
ted. If the opening force is set too high, this can
result in damage to property or injury to persons.
In the case of extremely smooth-running doors, a lower
setting can be selected if the sensitivity to obstructions
is to be increased.
Switch to menu 0 by pressing the PRG button.
5.2.7 Door behaviour before/at the OPEN travel limit
(see figure 32)
In menu 9 the automatic belt relief and the braking be-
haviour at the “OPEN“ travel limit can be influenced.
Display “Soft“ stop Relief
0 * long automatic
1 long without
2 long short
3 short automatic
4 short without
5 short short
6 without automatic
7 without without
8 without short
Switch to menu 0 by pressing the PRG button.
Note
For up-and-over doors we recommend setting the “soft“
stop at long.
6 Trouble-shooting (see page 54)
7 Terms and Conditions of the Warranty
Guarantee Period
In addition to the statutory guarantee provided by the
dealer, we provide the following guarantee of parts from
the date of purchase:
a) 5 years on operator mechanics, motor and motor
controls
b) 2 years on radio, impulse generators, accessories
and special systems
There is no guarantee on consumables (e.g. fuses,
batteries, lighting devices).
Claims made under the guarantee do not extend the
guarantee period. Following the supply of replacement
parts the guarantee period is six months; or at least,
the remainder of the guarantee period.
Conditions
A claim under this guarantee is only valid for the country
in which the equipment was bought. The product must
have been purchased through authorised distribution
channels. A claim under this guarantee exists only for
damage to the product in the contract itself. Reimburse-
ment of expenditure for dismantling and installation,
testing of corresponding parts, as well as demands for
lost profits and compensation for damages, are excluded
from the guarantee. The receipt of purchase substan-
tiates your right to claim under the guarantee.
Service rendered
For the duration of the guarantee we will eliminate all
product defects that are proven to be attributable to
material or manufacturing faults. We pledge to provide
free of charge and at our discretion to replace the de-
fective parts with a non-defective one, to improve it, or
to reimburse for a reduction in price.
Excluded are damages due to:
- improper fitting and connection
- improper commissioning or operating
- external influences, such as fire, water, abnormal
weather conditions
- mechanical damage due to accidents, dropping, jolting
- negligent or deliberate destruction
- normal wear and tear or deficient maintenance
52
05.2004 TR10A011 RE