7104.2007 TR10A041-C RE
ENGLISH
8 Error messages and warnings
Note: In the event of an error or warning a number is displayed with a rapidly flashing decimal point.
Display Fault/Error/Warning Possible Cause Remedy
Reversing limits cannot
be set
Partial opening height
cannot be set
Entry not possible
Travel command not
possible
Excess travel stop
System fault
Force limit
Closed circuit
Photocell
Closing edge safety
device
No reference point
Operator not
programmed
The operator is at the Open
end-of-travel position
Obstruction when setting the reversing limit "closing
edge safety device/leading photocell"
Partial opening height too close to the CLOSE
end-of-travel position (≤ 120 mm carriage travel)
Parameter in menu 4 set to 0, and activation of
automatic closing tried (menu 3, parameters 1-9)
Travel command given but operator blocked for
control elements
Belt torn
Operator defective
Internal error
Door moves sluggishly or unevenly
Obstruction in door area
Wicket door is open
Solenoid incorrectly installed (wrong way round)
Self-monitoring unit defective
Photocell not connected
Light path interrupted
Photocell defective
Light path interrupted
Power failure
Operator not programmed
Remove obstruction
Partial opening height must be larger
Activate safety device/s
Release operator for control elements
Replace belt
Replace operator
Restore factory settings (see section 4.6)
and reprogramme operator;
replace, if necessary
Correct door movement
Remove obstruction, reprogramme operator,
if necessary
Close wicket door
Install solenoid correctly (see instructions
for wicket door contact)
Replace wicket door contact
Connect photocell or set parameter in
menu 4 to 0
Adjust photocell
Replace photocell
Check transmitter and receiver,
replace, if necessary or completely replace
closing edge safety device
Move door to Open end-of-travel position
Programme operator
The operator is at the Closed
end-of-travel position
The operator is at the intermediate
position
The operator is partly open
The operator is running
Impulse input (radio code)