CM67
CHRONOTHERM
PRODUCT SPECIFICATION SHEET
T
he
C
M
6
7 Chronotherm is designed to provide automatic
time and temperature control of heating or cooling systems
in villas and apartments. It can be used as part of a system
in conjunction with combi boilers, oil- burners and gas fired
boilers, circulation pumps, thermal actuators, zone valves
and electric heat systems (<8A).
The
CM67 is designed with the installer in mind and includes
a moulded backplate with trunking guides and wiring
breakouts to make installation quick and easy.
The
CM67 display, buttons and slider layout are based on
the same simple programming philosophy used on the
acclaimed CM51 product. The unit is ideal for consumers
who want reliable precise temperature control from a simple
to program easy to use product.
FEATURES
Attractive slim styling makes it ideal for location in
any home.
7-day program
6 daily independent time and temperature level
changes let you set 6 time and temperatures pairs to
suit your life style.
Temporary programmed temperature override to
temporarily override the programmed temperature
till the next switch point.
Party button to temporarily maintain (or adjust)
the current temperature for 1-23 hours.
Day Off button copies Sunday’s program into
tomorrow or today to allow a rest day program
without having to re-program the CM
67.
Holiday button provides energy savings by
reducing the temperature for 1 to 99 days when
people are on holiday, returning to normal operation
(AUTO or MANUAL) on the day of return.
EEPROM memory holds the user program
indefinitely.
Telephone Interface (optional) can be fitted to the
CM
67 to allow switching between programmed mode
(slider position) and fixed set-point of 21
o
C.
24...230V 8A resistive, 3A inductive SPDT relay
provides compatibility with most domestic central
heating systems without stocking many different
models.
S
urface or wallbox mounting options, trunking
guides and wiring breakouts simplify installation.
OFF position on the slider has an integral fixed frost
protection setting at minimum of 5°
°°
°C (installer
adjustable) so that pipes in the house will never
freeze in winter.
Installer Set-Up Mode allows extra functions to be
set at the discretion of the installer to match the
consumers applications :
Optimisation
Pump Exercise
Upper / Lower Setpoint Limit Adjust
Temperature offset
Minimum ON time
Cycle rate
Heat / Cool Operation
Proportional Band Width
CM67 has provision for add-on modules to allow the
installer to sell additional features during or after the
first CM
67 installation, giving the installer an
additional sale.
Outside Temperature Sensor accessory (optional)
can be fitted to the CM
67 to display the external
temperature.
Remote Temperature Sensor (optional) can be fitted
to the CM
67 to control the temperature from another
room.
CM67 CHRONOTHERM
EN0R 8498 R2 11/98 2
SPECIFICATIONS
CM67 CONTROLS/DISPLAY LAYOUT
Batteries : 2 x 1.5 V IEC LR6 (AA) Alkaline cells
Battery life : 4 years typical (Duracell MN1500) for
applications with loads <3A
: 3 years typical for electric heat
applications (>3A, <8A)
Battery
replacement
: Program retained in EEPROM
Switch type : SPDT (potential free)
Electrical rating : 230 V~, 50...60 Hz, 0.5 A to 8 A resistive
0.5 A to 3 A inductive (0.6 pf)
24 V~, 50...60 Hz, 0.5 A to 8 A resistive
0.5 A to 3 A inductive (0.6 pf)
Time display : 24 hour or 12 hour AM/PM format
Time keeping
accuracy
: Typically better than 10 minutes per year
Program : 7-day with 6 daily time and temperature
level changes
Time setting
resolution
: Time of day - 1 minute
Program - 10 minute steps
Sensing element : 100K (@ 25
o
C)NTCthermistor
Temperature
setting range
: Program : 5 to 30
o
Cin0.5
o
Csteps
Frost : 5
o
C or equal to lower limit
(5
o
Cto16
o
C). Frost protection does not
work in cooling mode
T
emperature
c
ontrol accuracy
:
±
0.5 K (nominal) @ 20
o
C, 50% load
3K/hour
Room
Temperature
display range
: From 0
o
Cto40
o
C
Control form
: P + I (Proportional + Integral)
Minimum ON
time
: 10% of cycle time (min one minute),
adjustable to 2 to 5 min (see installer set
up)
Cycle rate
: 3, 6( default), 9, 12. Selectable through
the installer set up mode.
Wiring
: Terminal block capable of accepting
wiresupto2.5mm
2
Wire access : Mains wiring - rear, left or below
Low voltage wiring - rear, left or below
Dimensions
: 130 x 87R(82L) x 29 mm (w x h x d)
130 x 172 x 29 mm (w x h x d) (flap
open)
Environmental
: Operating temperature range 0 to 40
o
C
Shipping and storage temperature range
-20to55
o
C
Humidity range 0 to 90% rh, non-
condensing
Approvals
: Designed to meet European EN
pprovals EN60730-1(1995), EN55014-1
(1997), EN55014-2 (1996)
CM67 CHRONOTHERM
3 EN0R 8498 R2 11/98
INSTALLER SET-UP
To enter the installer set-up mode :
a) Set the program slider to OFF.
b) Press and hold Info
i button and press PROG 3,4
together.
c) The unit will display the first parameter of the installer
parameter group category 1 (from n.1 to n.5).
d) Press TEMP
or to change factory setting. The
display will flash indicating that a change has been
made.
e) Press INFO
i button to confirm the change. The display
will stop flashing.
f) Press
+or-togotonextparameter.
g) Press PROG 2 button to go to Installer parameter group
category 2 (from parameter n.6 to parameter n.16).
h) To exit installer mode move the slider in MAN or AUTO
position.
Specific Applications Setting What do you need to change ?
Cycle/
Hour
Minimum
ON time
(in minutes)
Note :
a. To change Cycle/Hour, please go to parameter n. 9 in the
installer set-up mode.
b. To change Minimum ON Time, please go to parameter n. 2 in
the installer set-up mode.
Heating Gas Boilers
(<30KW)
6 1 No action required
Oil Boiler 3 4 1. Set Minimum ON Time to 4 minutes.
2. Set Cycle/Hour to 3.
Thermal
Actuator
12 1 Set Cycle/Hour to 12.
Zone valve 6 1 No action required.
Electric heating
(for applications
<8A)
12 1 1. Configure the Chronotherm for electric heating (set parameter
n.7 in the installer set up mode to 1).
2. Set Cycle/Hour to 12.
Air
conditioning
1. For cooling application only, set the Chronotherm to cooling
(set parameter n.6 in the installer set-up mode to 0)
2. For heat/ cool application, set the Chronotherm accordingly to
required mode of operation
winter = heating
summer = cooling
by changing parameter n.6 in the installer set-up mode. Explain to
the end-user how to implement the change-over.
Heat Pump/
Air conditioner
3 4 1. Set Minimum ON Time to 4 minutes .
2. Set Cycle/Hour to 3.
In Installer set up we can :
Set-up specific applications
Enable special features
Establish support for Optional Accessories
1
Abbreviated Set-Up Description
e.g. OP = Optimisation
Installer Set-up Number
(Press + or - to change)
e.g. 1 = Optimisation
Installer Set-Up Mode
Selected
Factory Setting or New Choice
Press TEMP or to change
e.g. O = Optimisation disabled
1 = Optimisation enabled
CM67 CHRONOTHERM
EN0R 8498 R2 11/98 4
Special Features Description What to do if we wish this
feature
Optimisation (Variable
Start Time)
Adaptive Intelligence
recovery TM
The Chronotherm will adjust the start time in the
morning/ afternoon so the desired temperature is
reached by the start of the program period e.g. Time
7:00, Temp 21
o
C. The Chronotherm will monitor the
accuracy of the start up and use this information to
modify the calculation for the following day by
changing the ramp rate (initial 3 K/hr) .The system will
restrict the start time to a max of 3 hours.
Optimisation will not work in cooling mode.
Set parameter. 1 in the installer set-
up mode to 1.
AM-PM/ 24hr Display Change display format (default 24hr) Set parameter n.3 in the installer set -
up mode to 1.
Pump exercise When enabled the Pump Exercise will switch the relay
on for 1 minute at 12:00 if the relay has not been
switched on since 12:00 the previous day.
While in Holiday mode the Pump Exercise feature, if
enabled, will operate.
Set parameter n.8 in the installer set -
up mode to 1.
Upper Temperature
Limit
The normal upper temperature limit of 30
o
C can be
reduced down to 21
o
C to save energy. Useful for small
commercial premises.
Set parameter n.11 in the installer set
-up mode to the desired limit.
Lower Temperature
Limit
The normal lower temperature limit of 5
o
C can be
increasedupto16
o
C to protect the inhabitants from
cold. Useful if the inhabitants include the elderly,
children or disabled.
Set parameter n.12 in the installer set
-up mode to the desired limit.
Temperature Offset If the Chronotherm is located in a hot/cold location and
cannot be moved because of wiring then the measured/
displayed temperature can be adjusted by +/- 3
o
C.
Useful if the homeowner wants the reading to match
another appliance temperature display.
Set parameter n.13 in the installer set
-up mode to the desired offset value.
Proportional Band Width Can be adjusted up to 3
o
C (default is 1.5
o
C) to provide
better temperature control (less overshoot).
Useful for:
a. Well insulated homes with over-sized heating
systems
b. Air systems with fast response
Set parameter n.15 in the installer set
-up mode to the desired value.
Optional
Accessories
Description What to do if we wish this
feature
Outside Temperature
Sensor
An Outside Temperature Sensor can be fitted to your
CM67
to allow the homeowner to display the outside
temperate on the Chronotherm display by using the
INFO
i button. CM67 will read the outside temperature
every 10 minutes. Outside temperature display range is
from -30
o
Cto+45
o
C. The sensor can be connected up
to 50 meters from the unit.
1. Fit the sensor (instructions
included in the sensor package)
2. Set parameter n. 10 in the
installer set-up mode to 1
Remote Temperature
Sensor
A Remote Temperature Sensor can be fitted to your
CM67
to allow the Chronotherm to control temperature
from another room or space where it is inconvenient to
locate the CM67
It will read the remote sensor every 1
minute. The sensor can be connected up to 50 meters
from the unit. Useful for commercial premises where
the public may tamper with the product.
1. Fit the sensor (instructions
included in the sensor package)
2. Set parameter n. 10 in the
installer set-up mode to 2
Automatic Time Setting
(ATS) Module
The ATS module picks up a time signal daily from a
European transmitter, so you never need to set or
adjust the time.
1. Fit the ATS module
2. Set parameter n. 4 in the installer
set-up mode to 1
CM67 CHRONOTHERM
EN0R 8498 R2 11/98 6
DIMENSIONS
LOCATION
The CM67 Chronotherm is the temperature control element
in the heating/cooling system and MUST be located in a
position with good air circulation at average room
temperature on an inside wall 1.5 metres above the floor
level. Do not position the CM67 Chronotherm near sources
of heat (radiators, hot air vents, TV or lights), near doors or
w
indows, or in direct sunlight.
MOUNTING
The CM67 Chronotherm can be mounted directly on the wall
surface or on an electrical wallbox.
WIRING
The CM67 Chronotherm is designed for fixed wiring only and
must be installed in accordance with latest l.E.E. regulations.
Ensure the wiring connection to the supply is via a fuse rated
at no more than 8 amps and a Class "A" switch (having
contact separation of at least 3 mm in all poles).
IMPORTANT
1. The installer must be a trained service engineer
2. Disconnect the power supply before beginning
installation
INSTALLATION
CM67 CHRONOTHERM
Honeywell Control Systems Limited http://europe.hbc.honeywell.com
Newhouse Industrial Estate
Motherwell ML1 5SB
United Kingdom
EN0R 8498 R2 11/98
WIRING
Description Model Logo Literature Spec Sheet
7-day
programmable
thermostat
T6667B1002 Honeywell English ENOR8498
Remote sensor T7043G1004 Honeywell Multi-
Language
ENOR8496
Outside temp
sensor
F42009537-
001
Multi-
Language
ENOR8495
Automatic
Time Setting
Module Europe
Q6667B1007 Multi-
Language
ENOR8501
N
OTE: The model shown opposite
can be ordered as samples to
establish the exact
customisation requirements
ORDERING SPECIFICATION
1

Hulp nodig? Stel uw vraag in het forum

Spelregels
1

Forum

Honeywell-CM67-CHRONOTHERM
  • Bij mij kwam er vorige week niks meer op het scherm, ik dacht dat het aan de batterijen lag, nieuw batterijen ingestopt....helaas nog altijd geen scherm.
    Wie kan me helpen?
    Alvast bedankt Gesteld op 9-10-2021 om 12:14

    Reageer op deze vraag Misbruik melden
  • Ik heb ook een Thermostaat honeywell cm67,jaren ging alles goed,als ik hem in man zet geen enkel probleem,zet ik hem in automatisch om aan te slagen s'morgens ok maar op het laatste instelprogramma heb ik hem geplaatst op 23.45 uur en temperatuur op 5 graden geplaatst voor de nacht,kijk ik dan op knop info duid hij 16 graden aan,rezultaal die slaagt aan wanneer het koud wordt,zou niet mogen wegens ik in laatste programma maar 5 graden instel,wat moet ik daaraan doen,graag antwoordje vdcjp@telenet.be,dank u Gesteld op 30-11-2020 om 22:18

    Reageer op deze vraag Misbruik melden
  • Mijn cm67 die ik al jaren gebruikt zonder problemen doet nu plots raar.
    Hij staat geprogrammeerd per dag:
    6 u=1e program 22graden
    9u =2e program 18 graden
    16u = 3e program 22 graden
    Enz...
    Wel nu op het 2 e program op donderdag geeft mijn uitlezing gewoon streepjes .blijft dus gewoon doorgaan gans de dag.
    Ik heb zoals de handleiding zegt de schuiver verzet naar program en naar donderdag program 2 gegaan maar kan hier niets verzetten .die streepjes blijven
    Hoe komt dit plots?

    Heb geprobeerd het 1 e program op donderdag te verzetten via de gebruiksaanwijzing en dit lukt zowel de tijd als de temperatuur .
    Maar van program 2 op donderdag kan ik niets verzetten
    Iemand info?
    Mvg
    Gesteld op 13-2-2020 om 10:28

    Reageer op deze vraag Misbruik melden
  • Beste,wij hebben een CM67 met het volgende probleem : ook als wij de thermostaat op off zetten blijft deze toch verwarmen tot 24 graden,batterijen zouden goed moeten zijn want het symbool voor batterij leegloop licht niet op ,ook het interne fout symbool verschijnt niet
    Graag uw reactie op mylleville.vandenberghe@gmail.com of +32474909682 waarvoor dank ! Gesteld op 28-12-2014 om 18:46

    Reageer op deze vraag Misbruik melden
    • Beste,

      Kan het zijn dat de kloeling aanstaat?Dan staat er op het scherm een klein ventilater rechts boven, of dat er oplaadbatterijen inzitten.Je kan de volledige gebruiksaanwijziging terugvinden op Google met vermelding van CM67,heel duidelijke uitleg. Geantwoord op 29-12-2014 om 11:20

      Waardeer dit antwoord (3) Misbruik melden
  • Koeling staat niet aan,het blijkt een fout aan de ketel te zijn.Zeker bedankt voor de reactie ! Geantwoord op 29-12-2014 om 13:02

    Waardeer dit antwoord (3) Misbruik melden
  • Blij te horen dat het probleem is opgelost.Prettige feesten. Geantwoord op 29-12-2014 om 18:43

    Waardeer dit antwoord Misbruik melden
  • IK ben net verhuisd en heb een Honeywell CM67.
    Ik wil hem programmeren zodat hij elke dag om 7u aanslaat op 20°.
    Ik luk er echter niet in.
    Welke stappen moet ik zetten ?
    Is er een technieker in de buurt van De Haan om het te komen uitleggen ?

    Met dank. Witdoeckt Joost Gesteld op 11-12-2014 om 11:54

    Reageer op deze vraag Misbruik melden
    • U kan de handleiding downloaden op Honeywell CM 67 chromotherm via google,deze is heel duidelijk voor de progammatie van uw thermostaat. Veel succes Geantwoord op 11-12-2014 om 12:51

      Waardeer dit antwoord (1) Misbruik melden
  • Geachte medewerkers, Als ik vanwege de vakantie mijn thermostaat op off zet, blijft dan de programmering van de hele week erin zitten, kan ik na de vakantie gewoon weer activeren met automatisch of manueel???/ Bij voorbaat hartelijke dank Gesteld op 19-7-2014 om 12:26

    Reageer op deze vraag Misbruik melden
    • Geen probleem,zet hem in off stand en wanner je terug uit vakantie komt zet hem dan terug in automatisch;en alles zal terug zoals voorheen het programma dat is ingesteld doorvoeren.Veel succes ermee Geantwoord op 19-7-2014 om 13:43

      Waardeer dit antwoord Misbruik melden
6
  • Kun je mij de nederlandstalige handleiding laten geworden van de CM67 en vooral voor het instellen automatisch van de dagtemperatuur begin en einde. Dank bij voorbaat Gesteld op 19-12-2013 om 12:32

    Reageer op deze vraag Misbruik melden
    • U kan de volledige handleiding afdrukken via internet,alles staat er duidelijk in weergegeven
      voor het instellen van de dag en nachttemperatuur.Ga naar chronometer cm67 in google en alle gegevens en de nodige informatie zijn er beschikbaar.Veel succes. Geantwoord op 19-12-2013 om 12:48

      Waardeer dit antwoord (1) Misbruik melden
  • Wij hebben al lang een Chronotherm CM 67.

    Vandaag bleef hij verwarmen tot 23 graden, maar de instelling was tot 20,5 graden. Er was ook een aanduiding op de display van een soort ventilator (cooling ?) ???
    Momenteel verwarmt hij niet meer maar blijft een temperatuur aangeven van 23 graden ook al is het nu veel frisser. Moet deze Chronotherm vervangen worden ? Gesteld op 9-4-2013 om 20:01

    Reageer op deze vraag Misbruik melden
    • Beste,

      Probeer van de koeling op o te zetten onder de gebruikersaanwijzigingen van 6:HC.U kan ook bellen naar het nummer 02/7282386 voor verdere informatie en bijstand.De gebruikaanwijziging kan u ook via het internet afdrukken indien je er geen hebt.

      Succes alvast. Geantwoord op 10-4-2013 om 13:32

      Waardeer dit antwoord Misbruik melden

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Honeywell CM67 CHRONOTHERM bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Honeywell CM67 CHRONOTHERM in de taal/talen: Engels als bijlage per email.

De handleiding is 0,29 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Andere handleiding(en) van Honeywell CM67 CHRONOTHERM

Honeywell CM67 CHRONOTHERM Specificaties - Nederlands - 7 pagina's

Honeywell CM67 CHRONOTHERM Gebruiksaanwijzing - Deutsch - 2 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info