GENERATOR
EU1000i
Owner’s Manual
See page 84 for
Initial Use Instructions
H i
FM
C
AH
Click to Save As
31Z26602_cover_B
Keep this owner’s manual handy so that you can refer to it at any time.
This owner’s manual is considered a permanent part of the generator
and should remain with the generator if resold.
The information and specifications included in this publication were in
effect at the time of approval for printing. Honda Motor Co., Ltd.
reserves the right, however, to discontinue or change specifications or
design at any time without notice and without incurring any obligation
whatsoever.
The engine exhaust from this product
contains chemicals known to the State
of California to cause cancer, birth
defects or other reproductive harm.
California Proposition 65
This product contains or emits
chemicals known to the state of
California to cause cancer, birth defects
or other reproductive harm
Exhaust contains poisonous carbon
monoxide gas that can build up to
dangerous levels in closed areas.
Breathing carbon monoxide can
cause unconsciousness or death.
Never run the generator in a closed,
or even partly closed area where
people may be present.
<HOࡍ࡯ࠫ㧞㧜㧝㧠ᐕ㧝᦬㧝㧢ᣣޓᧁᦐᣣޓඦ೨㧝㧜ᤨ㧠㧢ಽ
QUICK REFERENCE INFORMATION
Fuel Type Unleaded gasoline with an ethanol
content of no more than 10% and a
pump octane rating of 86 or higher
Engine Oil Type SAE 10W-30, API SJ or later (or
equivalent), for general use
(see page 46)
Spark Plug Type ZFR5F (NGK)
Electrode Gap 0.028–0.031 in (0.7–0.8 mm)
Maintenance Before each
use
Check engine oil level.
Check air cleaner.
Check GFCI operation.
Check battery electrolyte.
First 20 hours Change engine oil.
Subsequent See MAINTENANCE SCHEDULE
(see page 41)
<HOࡍ࡯ࠫ㧞㧜㧝㧠ᐕ㧝᦬㧝㧢ᣣޓᧁᦐᣣޓඦ೨㧝㧜ᤨ㧠㧥ಽ
1
INTRODUCTION
Congratulations on your selection of a Honda generator. We are certain
you will be pleased with your purchase of one of the finest generators
on the market.
We want to help you get the best results from your new generator and
to operate it safely. This manual
contains all the information on how to
do that; please read it carefully.
As you read this manual, you will
find information preceded by a
symbol. That info
rmation is intended to help you avoid
damage to your generator, other property, or the environment.
We suggest you read the Distributor’s Limited Warranty (s
ee page 74)
to fully understand its coverage and your responsibilities of ownership.
When your generator needs scheduled
maintenance, keep in mind that
your Ho
nda Power Equipment servicing dealership personnel are
specially trained in servicing Honda generators and are supported by
the parts and service divisions of American Honda. Your Honda
servicing dealer is dedicated to your satisfaction and will be pleased to
answer your questions and concerns.
Best Wishes,
Honda Motor Co., Ltd.
31Z40600.book 1 ページ 2013年5月27日 月曜日 午前11時28分
2
A FEW WORDS ABOUT SAFETY
Your safety and the safety of others are very important. And using this
generator safely is an important responsibility.
To help you make informed decisions about safety, we have provided
operating procedures and
other information on labels and in this
manual. This information alerts you to potential hazards that could hurt
you or others.
Of course, it is not practical or possible to warn you about all the
hazards associated wi
th operating or maintaining a generator. You
must use your own good judgment.
You will find important safety informati
on in a variety of forms,
including:
Safety Labels — on
the generator.
Safety Messages preceded by a safety alert symbol and one of
three signal words, DANGER, WARNING, or CAUTION.
These signal words mean:
Safety Headings — such as IMPORTANT SAFETY INFORMATION.
Safety Section — such as GENERATOR SAFETY.
I
nstructions — how to use this generator correctly and safely.
This entire book is filled wi
th important safety information — please
read it carefully.
You WILL be KILLED or
SERIOUSLY HURT if
you don’t follow instructions.
You CAN be KILLED or SERIOUSLY HURT if
you d
on’t follow instructions.
You
CAN be HURT if you don’t follow
instructions.
31Z40600.book 2 ページ 2013年5月27日 月曜日 午前11時28分
3
CONTENTS
GENERATOR SAFETY .................................................................6
IMPORTANT SAFETY INFORMATION ........................................6
Operator Responsibility ......................................................... 6
Carbon Monoxide Hazards..................................................... 6
Electric Shock Hazards.......................................................... 7
Fire and Burn Hazards........................................................... 7
Refuel With Care.................................................................. 8
SAFETY LABEL LOCATIONS .....................................................9
CONTROLS & FEATURES .......................................................... 11
COMPONENT & CONTROL LOCATIONS ................................... 11
CONTROLS .......................................................................... 13
Engine Switch.................................................................... 13
Starter Grip ....................................................................... 13
Fuel Filler Cap Vent Lever.................................................... 14
Choke Lever ...................................................................... 14
Eco-Throttle Switch............................................................ 15
Parallel Operation Outlets .................................................... 15
DC Receptacle ................................................................... 16
DC Circuit Protector ........................................................... 16
FEATURES ........................................................................... 17
Output Indicator................................................................. 17
Overload Indicator .............................................................. 17
Oil Alert Indicator ............................................................... 18
Ground Terminal ................................................................ 18
BEFORE OPERATION ................................................................ 19
ARE YOU READY TO GET STARTED? ...................................... 19
Knowledge ........................................................................ 19
IS YOUR GENERATOR READY TO GO? .................................... 19
Check the Engine ............................................................... 20
31Z40600.book 3 ページ 2013年5月27日 月曜日 午前11時28分
4
CONTENTS
OPERATION ............................................................................. 21
SAFE OPERATING PRECAUTIONS ........................................... 21
STARTING THE ENGINE ......................................................... 22
STOPPING THE ENGINE ......................................................... 25
AC OPERATION .................................................................... 27
AC Applications ................................................................. 29
AC PARALLEL OPERATION .................................................... 30
AC Parallel Operation Applications............
............................ 32
DC OPERATION .................................................................... 34
ECO-THROTTLE SYSTEM ....................................................... 37
STANDBY POWER ................................................................. 38
Connections to a Building’s Electrical System ...........
............. 38
System Ground .................................................................. 38
Special Requirements.......................................................... 39
SERVICING YOUR GENERATOR ................
................................. 40
THE IMPORTANCE OF MAINTENANCE .................................... 40
MAINTENANCE SAFETY ........................................................ 41
Safety Precautions ............................................................. 41
MAINTENANCE SCHEDULE .................................................... 42
REFUELING ........................................................................... 43
FUEL RECOMMENDATIONS .................................................... 44
ENGINE OIL LEVEL CHECK ..................................................... 45
ENGINE OIL CHANGE ............................................................ 47
ENGINE OIL RECOMMENDATIONS .......................................... 48
AIR CLEANER SERVICE .......................................................... 49
FOAM AIR FILTER CLEANING ................................................. 50
SPARK PLUG SERVICE ........................................................... 51
SPARK ARRESTER SERVICE ................................................... 53
STORAGE ................................................................................ 55
STORAGE PREPARATION ....................................................... 55
Cleaning............................................................................ 55
Fuel.................................................................................. 55
Engine Oil.......................................................................... 59
STORAGE PRECAUTIONS ...................................................... 60
REMOVAL FROM STORAGE ................................................... 60
31Z40600.book 4 ページ 2013年5月27日 月曜日 午前11時28分
5
CONTENTS
TRANSPORTING ...................................................................... 61
TAKING CARE OF UNEXPECTED PROBLEMS ............
................... 62
ENGINE WILL NOT START ...................................................... 62
ENGINE LACKS POWER ......................................................... 63
NO POWER AT THE AC RECEPTACLES ................................... 64
NO POWER AT THE DC RECEPTACLE ..................................... 64
TECHNICAL INFORMATION ....................................................... 65
Serial Number Location ....................................................... 65
Carburetor Modification for High Altitude Operation .......
......... 66
Emission Control System Information .................................... 67
Air Index ........................................................................... 69
Specifications .................................................................... 70
Wiring Diagram .................................................................. 71
CONSUMER INFORMATION ....................................................... 72
Dealer Locator Information .................................................. 72
Honda Publications ............................................................. 72
Customer Service Information .............................................. 73
Distributor’s Limited Warranty ............................................. 74
Emission Control System Warranty .
..............
........................ 79
INITIAL USE INSTRUCTIONS ..................................................... 84
ENGINE OIL .......................................................................... 84
FUEL ................................................................................... 85
BEFORE OPERATION ............................................................. 87
REGISTRATION ..................................................................... 87
INDEX ..................................................................................... 88
QUICK REFERENCE INFORMATION......................... Inside back cover
31Z40600.book 5 ページ 2013年5月27日 月曜日 午前11時28分
6
GENERATOR SAFETY
IMPORTANT SAFETY INFORMATION
Honda generators are designed for use with electrical equipment that
has suitable power requirements. Other uses can result in inj
ury to the
operator or damage to the generator and other property.
Most injuries or property damage can be prevented if you follow all
instructions in this manual
and on the generator. The most common
hazards are discussed below, along with the best way to protect
yourself and others.
Operator Responsibility
Know how to stop the generator quickly in case of emergency.
Understand the use of all generator controls, output receptacles, and
connections.
Be sure that anyone who operates the generator receives proper
instruction. D
o not let children operate the generator without parental
supervision.
Carbon Monoxide Hazards
A generator's exhaust contains toxic carbon monoxide, which you
cannot see or
smell. Breathing carbon monoxide can KILL
YOU IN
MINUTES. To avoid carbon monoxide poisoning, follow these
instructions when operating a generator:
Only run a generator OUTSIDE, far away from windows, doors, and
vents.
Never operate a generator inside a house, garage, basement, crawl
spa
ce, or any enclosed or partially enclosed space.
Never operate a generator near open doors or windows.
Get fresh air and seek medical attention
immediately if you suspect
you
have inhaled carbon monoxide.
Early symptoms of carbon monoxide exposure include headache,
fatigue, shortness
of breath, nausea, and dizziness. Continued exposure
to carbon monoxide can cause loss of muscular coordination, loss of
consciousness, and then death.
31Z40600.book 6 ページ 2013年5月27日 月曜日 午前11時28分
7
GENERATOR SAFETY
To alert you to potentially dangerous levels of carbon monoxide
coming from a generator operating outside or from other sources,
install battery operated carbon monoxide alarms or plug-in carbon
monoxide alarms with battery back-up on every level of the home and
outside sleeping areas, according to the manufacturer's instructions.
Electric Shock Hazards
The generator produces enough electric power to cause a serious
shock or ele
ctrocution if misused.
Using a generator or electrical appliance in wet conditions, such as
rain or snow, or near a pool or sprinkler system
, or when your
hands are wet, could result in electrocution. Keep the generator dry.
If the generator is stored outdoors, unprotected from the weather,
check all of the electrical components on the control p
anel before
each use. Moisture or ice can cause a malfunction or short circuit in
electrical components that could result in electrocution.
Do not connect to a building’s electrical system unless an isolation
switch has been installed by a qualified electrician
.
Use only a Honda-approved parallel operation cable (optional
equipment) when connecting
two EU1000i generators for parallel
operation.
Never connect different generator models.
Fire and Burn Hazards
The exhaust system gets hot enough to ignite some materials.
Keep the generator at least 3 feet (1 meter) away from buildings
and other equipment during operation.
Do not enclose the generator in any structure.
Keep flammable materials away from the generator.
The muffler becomes very hot during operation and remains hot for
a while after stopping the engine. Be careful no
t to touch the muffler
while it is hot. Let the engine cool before storing the generator
indoors.
31Z40601-01.fm 7 ページ 2014年5月15日 木曜日 午後7時5分
8
GENERATOR SAFETY
Refuel With Care
Gasoline is extremely flammable, and gasoline vapor can
explode.
Allow the engine to cool if the generator has been in operation.
Refuel only outdoors in a well-ventilated area with the engine off.
Do not refuel during operation.
Do not overfill the fuel tank.
Never smoke near gasoline, and keep other flames and sparks away.
Always store gasoline in an approved container.
Make
sure that any spilled fuel has been wiped up before starting the
engine.
31Z40600.book 8 ページ 2013年5月27日 月曜日 午前11時28分
9
GENERATOR SAFETY
SAFETY LABEL LOCATIONS
These labels warn you of potential hazards that can cause serious
injury. Read them carefully. If a label comes off or becomes hard to
read, contact your Honda servicing dealer for a replacement.
31Z40600.book 9 ページ 2013年5月27日 月曜日 午前11時28分
10
GENERATOR SAFETY
31Z40600.book 10 ページ 2013年5月27日 月曜日 午前11時28分
11
CONTROLS & FEATURES
COMPONENT & CONTROL LOCATIONS
Use the illustrations on these pages to locate and identify the most
frequently used
controls.
PARALLEL OPERATION OUTLETS
AC RECEPTACLES
ECO-THROTTLE SWITCH
GROUND TERMINAL
OIL ALERT INDICATOR
OVERLOAD INDICATOR
OUTPUT INDICATOR
DC RECEPTACLE
DC CIRCUIT PROTECTOR
FUEL FILLER CAP VENT LEVER
FUEL FILLER CAP
STARTER GRIP
CHOKE LEVER
MAINTENANCE
COVER
ENGINE SWITCH
31Z40600.book 11 ページ 2013年5月27日 月曜日 午前11時28分
12
CONTROLS & FEATURES
31Z40600.book 12 ページ 2013年5月27日 月曜日 午前11時28分
13
CONTROLS & FEATURES
CONTROLS
Engine Switch
The engine switch controls the
ignition system and the fuel valve.
OFF – Stops the engine and
closes the fuel valve.
ON – Runn
ing position; opens the
fuel valve and allo
ws the engine
to be started.
Starter Grip
Pulling the starter grip operates
the re
coil starter to start the
engine.
Do not allow the starter grip to
snap back against the
generator.
Return it gently to prevent
damage to the starter.
ENGINE SWITCH
STARTER GRIP
OFF
ON
31Z40600.book 13 ページ 2013年5月27日 月曜日 午前11時28分
14
CONTROLS & FEATURES
Fuel Filler Cap Vent Lever
The fuel filler cap is provided with a vent lever to seal the fuel tank.
The fuel filler cap vent lever must be in the ON position for the engine
to ru
n.
When the engine is not in use, leave the fuel filler cap vent lever in the
OFF position to reduce the possi
bility of fuel leakage. Allow the engine
to cool before turning the fuel filler cap vent lever to the OFF position.
Choke Lever
The choke is used to provide
proper starting mixture when the
engine is cold. It can be opened
and cl
osed by operating the choke
lever manually. Move the choke
lever to the CLOSED position to
enrich the mixture for cold
starting.
CHOKE LEVER
OPEN
CLOSED
31Z40600.book 14 ページ 2013年5月27日 月曜日 午前11時28分
15
CONTROLS & FEATURES
Eco-Throttle
Switch
The Eco-Throttle
system automatically reduces engine speed when
loads are turned off or disconnected. When appliances are turned on or
reconnected, the engine returns to the proper speed to power the
electrical load.
If high electrical loads are connected simultaneously, turn the
Eco-Throttle switch to the OFF position to reduce voltage changes.
ON: Recommended to minimize fuel consumption and further
reduce noise levels when less than a full load is applied to the
generator.
OFF: The Eco-Throttle system does not operate.
When using the DC output, turn the Eco-Throttle switch to the
OFF position.
Par
allel Oper
ation Outlets
These outlets are used for connecting two EU1000i generators for
parallel operation (see page 30). A Honda-approved parallel operation
cable (optional equipment) is required for parallel operation. This cable
can be pu
rchased from an authorized Honda genera
tor dealer.
31Z40601-01.fm 15 ページ 2014年6月2日 月曜日 午後2時48分
16
CONTROLS & FEATURES
DC Receptacle
The DC receptacle should ONLY be used for charging 12 volt
automotive
type batteries. The DC charging output is not regulated.
This means that the charging output does not decrease as the battery
reaches full charge.
Check the battery voltage frequently while charging to prevent
overcharging the battery.
DC Circuit Protector
The DC circuit protector automatically shuts off the
DC battery
charging circuit when the DC charging circuit is overloaded, when
there is a problem with the battery, or when the connections between
the battery and the generator are improper. However, the DC circuit
protector does not prevent overcharging.
31Z40600.book 16 ページ 2013年5月27日 月曜日 午前11時28分
17
CONTROLS & FEATURES
FEATURES
Output Indicator
The output indicator (green) is illuminated when the generator is
operating normally. It indicates that the generator is producing
electrical power at the receptacles.
In addition, the output indicator has a
simplified hour meter function.
When you start the engine, the indicator blinks according to the
generator’s cumulative operating hours as follows:
No blinks: 0–100 hours
1 blink: 100–200 hours
2 blinks: 200–300 hours
3 blinks: 300–400 hours
4 blinks: 400–500 hours
5 blinks: 500 or more hours
Overload Indicator
If the generator is overloaded (in excess of 1.0 kVA), or if there is a
short circuit in a connected appli
ance, the overload indicator (red) will
come ON. The overload indicator (red) will stay ON, and after about
four seconds, current to the connected appliance(s) will shut off, and
the output indicator (green) will go OFF. However, the engine will
continue to run.
OUTPUT INDICATOR
(GREEN)
31Z40600.book 17 ページ 2013年5月27日 月曜日 午前11時28分
18
CONTROLS & FEATURES
Oil Alert® Indicator
The Oil Alert® system is designed to prevent engine damage caused by
an insufficient amount of oil in the crankcase.
Before the oil level in the
crankcase can fall below a safe limit, the Oil Alert indicator (red) comes
ON and the Oil Alert system automatically will stop the engine (the
engine switch will remain in the ON position).
If the engine stops or the Oil Alert indicator (red) comes ON
when you
pull the starter grip, check the engine oil level (see page 45) before
troubleshooting in other areas.
Ground Terminal
The generator ground terminal is connected to the frame of the
generator, the metal non-current-carrying
parts of the generator, and
the ground terminals of each receptacle.
Before using the ground terminal, consult a qualified electrician,
electrical inspector, or local
agency having jurisdiction for local codes
or ordinances that apply to the intended use of the generator.
OIL ALERT INDICATOR
(RED)
GROUND TERMINAL
31Z40600.book 18 ページ 2013年5月27日 月曜日 午前11時28分
19
BEFORE OPERATION
ARE YOU READY TO GET STARTED?
Your safety is your responsibility. A little time spent in preparation will
significantly reduce your risk of inju
ry.
Knowledge
Read and understand this man
ual. Know what the controls do and how
to operate them.
Familiarize yourself with the generator and its operation before
you
begin using it. Know how to quickly shut off the generator in case of
an emergency.
If the generator is being used to power appliances, be sure that they do
not exceed the generator’s load rating (see pages 29 and
33).
IS YOUR GENERATOR READY TO GO?
For your safety, to ensure compliance with environmental regulations,
and to maximize th
e service life of your equipment, it is very important
to take a few moments before you operate the generator to check its
condition. Be sure to take care of any problem you find, or have your
servicing dealer correct it, before you operate the generator.
Improperly maintaining this generator, or
failing to correct a problem before operation,
could cause a malfunction in which you
could be seriously injured.
Always perform a pre-operation inspection
before
each operation, and correct any
problem.
31Z40600.book 19 ページ 2013年5月27日 月曜日 午前11時28分
20
BEFORE OPERATION
To prevent a possible fire, keep the generator at least 3 feet (1 meter)
away from building walls and other equipment during operation. Do not
place flammable objects close to the engine.
Before beginning your pre-operation checks, be sure the generator is on
a level and firm surface and the engine switch is in the OFF position.
Check the Engine
B
efore each use, look around and underneath the engine for signs of
oil or gasoline leaks.
C
heck the engine oil level (see page 45). A low engine oil level will
cause the Oil Alert system t
o shut down the
engine.
Check the air filter (see page 49). A dirty air filter will restrict air flow
to the carburetor, reducing engine and generator performance.
Check the fuel level (see page 43). Starting with a full tank will help
to eliminate or reduce operating interruptions for refueling.
31Z40600.book 20 ページ 2013年5月27日 月曜日 午前11時28分
21
OPERATION
SAFE OPERATING PRECAUTIONS
Before operating the generator for the first time, review chapters
GENERATOR SAFETY
(see page 6) and
BEFORE OPERATION
(see page
19).
For your safety, do not operate the generator in an enclosed area such
as
a garage. Your generat
ors exhaust contains poisonous carbon
monoxide gas that can collect rapidly in an enclosed area and cause
illness or death.
Before connecting an AC appliance or power cord to the generator:
Use grounded 3-prong extension cords, tools, and appliances, or
double-insulated tools and appl
iances.
Inspect cords and plugs, and replace if damaged.
Make sure that the appliance is in good working order. Faulty
appliances or power cords can create a pote
ntial for electric shock.
Make sure the electrical rating of the tool or appliance does not
exceed the rated powe
r of the generator or the receptacle being
used.
Operate the generator at least 3 feet (1 meter) away from buildings
and other equipment.
Do n
ot operate the generator in an enclosed structure.
Do not place flammable objects close to the engine.
Exhaust contains poisonous carbon
monoxide gas that can build up to
dangerous levels in closed areas.
Breathing carbon monoxide can cause
unconsciousness or death.
Never run the generator in a closed, or even
partly closed area where people may be
present.
31Z40601-01.fm 21 ページ 2014年5月23日 金曜日 午後12時21分
22
OPERATION
STARTING THE ENGINE
To prevent a possible fire, keep the generator at least 3 feet (1 meter)
away from
building walls and other equipment during operation. Do not
place flammable objects close to the engine.
Operating this generator less than 3 feet (1 meter) from a building or
other obstru
ction can cause overheating and damage the generator.
For proper cooling, allow at least 3 feet (1 meter) of empty space
above and around the
generator.
Keep all cooling holes open and clear of debris, mud, water, etc.
Cooling holes are located on the side panel, the control panel, and
the bottom of the generator. If the cooling holes are blocked, the
generator may overheat and damage the engine, inverter, or
windings.
Refer to SA
FE OPERATING PRECAU
TIONS on page 21 and perform the
IS YOUR GENERATOR READY TO GO? checks (see page 19). Refer to
AC OPERATION (see page
27) or DC OPERATION (see page 34) for
connecting loads to the generator.
1.Make sure that all appliances connected to the generator are turned
off. The generator may be
hard to start if a load is connected.
2.Turn the fuel filler cap vent lever to the ON position.
31Z40600.book 22 ページ 2013年5月27日 月曜日 午前11時28分
23
OPERATION
3.Make sure the Eco-Throttle
switch is in the OFF position, or
more time will be required for
warm-up.
4.To start a cold engine, move the
choke lever to the CLOSED
position. To restart a warm
engine, leave the choke lever
in
the OPEN position.
5.Turn the engine switch to the
ON position.
ECO-THROTTLE SWITCH
OFF
CHOKE LEVER
OPEN
CLOSED
ENGINE SWITCH
OFF
ON
31Z40600.book 23 ページ 2013年5月27日 月曜日 午前11時28分
24
OPERATION
6.Pull the starter grip lightly until
you feel resistance; then pull
briskly in the direction of the
arrow as shown.
Do not allow the starter grip to
snap back against the
generator. Return it gently to
prevent damage to the starter.
7.If the choke lever was moved to
the CLOSED positio
n to start
the engine, gradually move it to
the OPEN position as the engine
warms up.
8.If you wish to use the
Eco-Throttle system, turn the
Eco-Throttle switch to the ON
position after the engine has
warmed
up for 2 or 3 minutes.
STARTER GRIP
Direction to pull
CLOSED
CHOKE LEVER
OPEN
ECO-THROTTLE SWITCH
ON
31Z40600.book 24 ページ 2013年5月27日 月曜日 午前11時28分
25
OPERATION
STOPPING THE ENGINE
To stop the engine in an emergency, simply turn the engine switch to
the OFF position. Under normal conditions, use the following
procedure.
1.Turn off or disconnect all appliances that are connected to the
generator.
2.Turn the engine switch to the OFF position.
3.Allow the engine to cool, and then turn the fuel filler cap vent lever
to the OFF
position.
31Z40600.book 25 ページ 2013年5月27日 月曜日 午前11時28分
26
OPERATION
4.If two generators were connected for parallel operation, disconnect
the parallel operation cable after stopping the engines if you do not
wish to resume parallel operation.
31Z40600.book 26 ページ 2013年5月27日 月曜日 午前11時28分
27
OPERATION
AC OPERATION
Before connecting an appliance to the generator, make sure that it is in
good working order and that its electrical rating does not exceed that
of the generator.
Most motorized appliances require more than their electrical rating for
startup. When
an electric motor is started, the overload indicator (red)
may come ON. This is normal if the overload indicator (red) goes OFF
within 4 seconds. If the overload indicator (red) stays ON, consult your
generator dealer.
1.Start the engine (see page 22) and make sure the output indicator
(green) comes ON.
OUTPUT INDICATOR
(GREEN)
OVERLOAD INDICATOR
(RED)
31Z40600.book 27 ページ 2013年5月27日 月曜日 午前11時28分
28
OPERATION
2.Plug the appliance into the receptacle.
3.Turn on the appliance.
If the generator is overloaded (see page 29), or if there is a short circuit
in a connected appliance, the overload indicator (red) will go
ON. The
overload indicator (red) will stay ON, and after about four seconds,
current to the connected appliance(s) will shut off, and the output
indicator (green) will go OFF. Stop the engine and investigate the
problem.
Determine if the cause is a short circuit in a connected appliance or an
overload. Correct the problem and restart
the generator.
31Z40600.book 28 ページ 2013年5月27日 月曜日 午前11時28分
29
OPERATION
AC Applications
Before connecting an appliance or power cord to the generator:
Make sure that it is in good working order. A faulty appliance or
power cord can create a potential for electrical shock.
If an appliance begins to operate abnormally, becomes sluggish, or
stops sudden
ly, turn it off immediately. Disconnect the appliance,
and determine whether the problem is the appliance or the rated load
capacity of the generator has been exceeded.
Most appliance motors require more than their rated wattage for
startup.
Make sure the electrical ra
ting of the tool or appliance does not exceed
the maximum power rating of the generator.
Maximum power is:
1.0
kVA
For continuous operation, do not exceed the rated power.
Rated power is:
0.9 kVA
In either case, the total power requirements (VA) of all appliances
connected must be considered. Appliance and power tool
manufacturer
s usually list
rating information near the model number or
serial number.
Substantial overloading that continuously lights the overload indicator
(red) may damage the generator. Marginal overloading that temporarily
lights the overload indicator (red) may shorten the service life of the
generator.
31Z40601-01.fm 29 ページ 2014年6月2日 月曜日 午後2時48分
30
OPERATION
AC PARALLEL OPERATION
Before connecting an appliance to either generator, make sure that the
appliance is in good wo
rking order and that its electrical rating does not
exceed that of the receptacle.
Most motorized appliances require more than their electrical rating for
startup. When
an electric motor is started, the overload indicator (red)
may come ON. This is normal if the overload indicator (red) goes OFF
within 4 seconds. If the overload indicator (red) stays ON, consult your
generator dealer.
During parallel operation, the Eco-Throttle switch should be in the same
position on both
generators.
1.Connect the parallel operation cable (optional equipment) between
the two EU1000i
generators following the instructions supplied with
the parallel operation cable.
2.Start the engines (see page 22) and make sure the output indicator
(green) on each generator comes ON (see page 27).
31Z40600.book 30 ページ 2013年5月27日 月曜日 午前11時28分
31
OPERATION
3.Plug the appliance following the instruction provided with the
parallel operation cable.
4.Turn on the appliance.
If the generators are overloaded (see page 33), or if there is a short
circuit in a connected appliance, the overload indicator (red) will go ON.
The overload indicator (red) will stay ON, and after
about four seconds,
current to the connected appliance(s) will shut off, and the output
indicator (green) will go OFF. Stop
both engines and investigate the
problem.
Determine if the cause is a short circuit in a connected appliance or an
overload. Correct the problem and restart
the generator.
31Z40600.book 31 ページ 2013年5月27日 月曜日 午前11時28分
32
OPERATION
AC Parallel Operation Applications
Follow the instructions included with the parallel operation cable.
Before
connecting an appliance or power cord to the generator:
Make sure that it is in good working order. A faulty appliance or
power cord can create a potential for electrical shock.
If an appliance begins to operate abnormally, becomes sluggish, or
stops suddenly, turn it off immediately.
Disconnect the appliance,
and determine whether the problem is the appliance or the rated load
capacity of the generator has been exceeded.
Never connect different generator models.
Use only a Honda-approved parallel operation cable (optional
equipment, see
page 72) when connecting two EU1000i generators
for parallel operation.
Never connect or remove the parallel operation cable when the
generator is running.
For single generator operation, the parallel operation cable must be
removed.
31Z40600.book 32 ページ 2013年5月27日 月曜日 午前11時28分
33
OPERATION
Most appliance motors require more than their rated wattage for
startup.
Make sure the electrical rating of the tool or appliance does not exceed
the
maximum power rating of the generator.
Maximum power in parallel operation is:
2.0 kVA
For continuous operation, do not exceed the rated power.
Rated power in parallel operation is:
1.8 kVA
In either case, the total power requirements (VA) of all appliances
connected must be
considered. Appliance an
d power tool
manufacturers usually list rating information near the model number or
serial number.
Substantial overloading that continuously lights the overload indicator
(red) may damage the generator. Marginal overloading that temporarily
lights the overload indicator (red) may shorten the service life of the
generator.
31Z40600.book 33 ページ 2013年5月27日 月曜日 午前11時28分
34
OPERATION
DC OPERATION
The DC receptacle should ONLY be used for charging 12 volt
automotive
type batteries. The DC charging output is not regulated.
This means that the charging output is constant; it does not decrease
as the battery reaches full charge. Check the battery voltage frequently
while charging to prevent overcharging the battery.
When using the DC output, turn the Eco-Throttle switch to the OFF
position.
Connecting the battery charging cable (optional equipment):
1.Before connecting the battery charging
cable to a battery that is
installed in
a vehicle, disconnect the vehicle battery ground cable
from the negative (–) battery terminal.
WARNING: Battery posts, terminals, and related accessories contain
lead and lead components. Wash hand
s after handling.
2.Plug the battery charging cable
into the DC receptacle of the
generator.
The battery gives off explosive hydrogen
gas during normal operation.
A spark or flame can cause the battery to
explode with enough force to kill or
se
riously hurt you.
Wear protective clothing and a face shield,
or have a skilled mechanic perform the
battery maintenance.
BATTERY CHARGING CABLE
(optional equipment)
BLACK LEAD
RED LEAD
31Z40600.book 34 ページ 2013年5月27日 月曜日 午前11時28分
35
OPERATION
3.Connect the red lead of the battery charging cable to the positive (+)
battery terminal and the black lead to the negative (–) battery
terminal.
4.Start the generator (see page 22).
Do not start the vehicle while the battery charging cable is connected
and the generator is running. The vehicle or
the generator may be
damaged.
An overloaded DC circuit, excessive current draw by the battery, or a
wiring problem will trip the DC circuit protector (PUSH button extends
out). If
this happens, wait a few minutes before pushing in the circuit
protector to resume operation. If the DC circuit protector continues to
go OFF, discontinue charging and see your authorized Honda generator
dealer. The circuit protector does not prevent overcharging the battery.
31Z40600.book 35 ページ 2013年5月27日 月曜日 午前11時28分
36
OPERATION
Disconnecting the battery charging cable (optional equipment):
1.Stop the engine.
2.Disconnect the black lead of the battery charging cable from the
negative (–) battery terminal.
3.
Disconnect the red lead of the battery charging cable from the
positive (+) battery terminal.
4.Disconnect the battery charging cable from
the DC receptacle of the
generator.
5.Co
nnect the vehicle battery ground cable to the negative (–) battery
terminal.
31Z40600.book 36 ページ 2013年5月27日 月曜日 午前11時28分
37
OPERATION
ECO-THROTTLE
SYSTEM
With the switch in the ON position, engine speed is automatically
lowered when loads are reduced, turned off, or disconnected. When
appliances are turned on or reconnected, the engine returns to the
proper speed to power the electrical load. In the OFF position, the
Eco-Throttle
system does not operate.
Appliances with large start-up power demands may not allow the
engine to reach normal operating rpm when they are connected to the
generator
. Turn the Eco-Throttle switch to the OFF position and
connect the appliance to the generator. If the engine still will not reach
normal operating speed, check that the appliance does not exceed the
rated load capacity of the generator.
If high electrical loads are connected simultaneously, turn the
Eco-Throttle switch to the OFF position to reduce voltage changes.
The Eco-Throttle system is not effective for use with appliances or
tools that require only momentary power
. If the tool or appliance will
be turned ON and
OFF quickly, the Eco-Throttle switch should be in the
OFF position.
When using the DC output, turn the Eco-Throttle switch to the OFF
position.
31Z40601-01.fm 37 ページ 2014年6月2日 月曜日 午後3時58分
38
OPERATION
STANDBY POWER
Connections to a Building’s Electrical System
Connections for standby power to a building’s electrical system must
be made by a qualified electr
ician. The connection must isolate the
generator power from utility power, and must comply with all
applicable laws and electrical codes.
In some areas, generators are required by law to be registered with
local utility companies. Check local regulations for proper registration
and use procedures.
System Ground
This generator has a syste
m ground that connects the generator frame
components to the ground terminals in the AC o
utput receptacles. The
system ground is not connected to the AC neutral wire.
Improper connections to a building’s
electrical system can allow current from the
generator to backfeed into the utility lines.
Such backfeed may electrocute utility
company workers or others who contact
the lines during a power outage, and the
generator may explode, burn, or cause fires
when utility power is restored.
Consult the utility company or a qualified
electrician prior to making any power
connections.
31Z40601-01.fm 38 ページ 2014年5月23日 金曜日 午後12時21分
39
OPERATION
Special Requirements
Do not lay the generator on its side when moving, storing, or operating
it. Oil may leak and damage the engine or your property.
There may be Federal or State Occupational Safety and Health
Admini
stration (OSH
A) regulations, local codes, or ordinances that
apply to the intended use of the generator. Please consult a qualified
electrician, electrical inspector, or the local agency having jurisdiction.
In some areas, generators are required to be registered with local
utility companies.
If the generator is used at a construction site, there may be additional
regu
latio
n
s th
at must be observed.
31Z40600.book 39 ページ 2013年5月27日 月曜日 午前11時28分
40
SERVICING YOUR GENERATOR
THE IMPORTANCE OF MAINTENANCE
Good maintenance is essential for safe, economical, and trouble-free
operation. It will also help reduce air pol
lution.
To help you properly care for your generator, the following pages
include a mainten
ance schedule, routine inspection procedures, and
simple maintenance procedures using basic hand tools. Other service
tasks that are more difficult or require special tools are best handled by
professionals and are normally performed by a Honda technician or
other qualified mechanic.
The maintenance schedule applies to normal operating conditions. If
you operate your generator u
nder unusual conditions, such as
sustained high-load or high-temperature operation, or use it in dusty
conditions, consult your servicing dealer for recommendations
applicable to your individual needs and use.
Remember that an authorized Honda servicing dealer knows your
generator best and is fully equipped to
maintain and repair it.
To ensure the best quality and reliability, use only new, Honda Genuine
parts or their equivalents for repair and replacement.
Maintenance, replacement,
or repair of the emission control devices
and systems
may be performed by any engine repair establishment or
individual, using parts that are ‘‘certified’’ to EPA standards.
Improper maintenance, or failure to correct
a problem before operation, can cause a
malfunction in which you can be seriously
hurt or killed.
Always follow the inspection and
maintenance recommendations
and
schedules in this owner’s manual.
31Z40600.book 40 ページ 2013年5月27日 月曜日 午前11時28分
41
SERVICING YOUR GENERATOR
MAINTENANCE SAFETY
Some of the most important safety precautions follow. However, we
cannot warn you of every conceivable hazard that can arise in
performing maintenance. Only you can decide whether or not you
should perform a given task.
Safety Precautions
Make sure the engine is off before you begin any maintenance or
repairs. This will eliminate several potential hazards:
Carbon monoxide poisoning from engine exhaust.
Operate outside away from open windows or doors.
Burns from hot parts.
Let the engine and exhaust system cool before touching.
Injury from moving parts.
Do not run the engine unless instructed to do so.
Read the instructions before you begin, and make sure you have the
tools and skills required.
To reduce the possibility of fire or explosion, be careful when
w
orking ar
ound gasoline. Use only a non-flammable solvent, not
gasoline, to clean parts. Keep cigarettes, sparks, and flames away
from all fuel-related parts.
Failure to properly follow maintenance
instructions and precautions can cause you
to be seriously hurt or killed.
Always follow the procedures and
precautions in the o
wner’s manual.
31Z40600.book 41 ページ 2013年5月27日 月曜日 午前11時28分
42
SERVICING YOUR GENERATOR
MAINTENANCE SCHEDULE
(1) Service more frequently when used in dusty areas.
(2) These items should be serviced by your servicing dealer, unle
ss you have the proper tools and
are mechanically proficient. Refer to the Honda shop manual for service procedures.
See ‘‘Honda Publications’’ on page 72 for ordering information.
(3) For commercial use, log hours of operation to determine proper maintenance intervals.
Failure to follow this maintenance schedule could result in non-warrantable failures.
REGULAR SERVICE PERIOD (3)
Perform at every indicated month
or operating hour interval,
whichever comes first.
ITEM
Each
use
First
month
or
10 hrs.
Every
3
months
or
50 hrs.
Every
6
months
or
100
hrs
.
Every
2 years
or
300
hrs
.
Page
Engine oil Check level o 45
Change o o 47
Air cleaner Check o 49
Clean o (1) 50
Spark plug Check-adjust o 51
Replace o 51
Spark arrester Clean o 53
Valve clearance Check-adjust o (2)
Combustion chamber Clean After every 300 hrs. (2)
Fuel tank and filter Clean Every year (2)
Fuel tube Check Every 2 years (Replace if necessary) (2)
31Z40600.book 42 ページ 2013年5月27日 月曜日 午前11時28分
43
SERVICING YOUR GENERATOR
REFUELING
With the engine stopped, remove the fuel filler cap and check the fuel
level. Refill the fuel tank if the fuel level is low.
Fuel can damage paint and plastic. Be careful not to spill fuel when
filling your fuel tank. Damage caused by spil
led fuel is not covered
under warranty.
Refuel in a well-ventilated area before starting the engine
. If the engine
has been running, allow it to cool. Refuel carefully to avoid spilling fuel.
Do not fill the fuel tank above the upper level mark (red) on the fuel
filter.
Never refuel
the engine inside a building where gasoline fumes may
reach flames or sparks. Keep
gasoline away from appliance pilot lights,
barbecues, electric appliances, power tools, etc.
Spilled fuel is not only a fire hazard, it causes environmental damage.
Wipe up spills immediately.
After refueling,
reinstall the fuel filler cap securely.
Gasoline is highly flammable and explosive.
You can be burned or seriously injured when
handling fuel.
Stop the engine and keep
heat, sparks,
and flame away.
Handle fuel o
nly outdoors.
Wipe up spills immediately.
31Z40600.book 43 ページ 2013年5月27日 月曜日 午前11時28分
44
SERVICING YOUR GENERATOR
FUEL RECOMMENDATIONS
This engine is certified to operate on regular unleaded gasoline with a
pump octane rating of
86 or higher.
Never use stale or contaminated gasoline or an oil/gasoline mixture.
Avo
id getting dirt or water in the fuel tank.
You may use regular unleaded gasoline containing no more than 10%
ethanol (E
10) or 5% methanol by volume. In addition, methanol must
contain cosolvents and corrosion inhibitors.
Use of fuels with content of ethanol or methanol greater than shown
above may cause starting and/or performance problems. It may also
damage metal, rubb
er, and plastic parts of the fuel system.
Engine damage or performance problems that result from using a fuel
with percentages of ethanol or m
ethanol greater than shown above are
not covered under warranty.
If your equipment will be used on an infrequent basis, please refer to
the
fuel section of the STORAG
E chapter (see page 55) for additional
information regarding fuel deterioration.
31Z40600.book 44 ページ 2013年5月27日 月曜日 午前11時28分
45
SERVICING YOUR GENERATOR
ENGINE OIL LEVEL CHECK
Check the engine oil level with the generator on a level surface and the
engine stopped.
1.Loosen the maintenance cover screw and remove the maintenance
cover.
MAINTENANCE COVER SCREW
MAINTENANCE COVER
31Z40600.book 45 ページ 2013年5月27日 月曜日 午前11時28分
46
SERVICING YOUR GENERATOR
2.Remove the oil filler cap.
3.Check the oil level. If it is below the upper limit, fill with the
recommended oil to the upper limit of the oil filler neck (see page
48
).
4.Reinstall the oil filler cap securely.
5.Reinstall the maintenance cover and tighten the maintenance cover
screw securely.
The Oil Alert
system will automatically stop the engine before the oil
level falls below safe limits. However,
to avoid the inconvenience of an
unexpected shutdown, check the oil
level regularly.
31Z40600.book 46 ページ 2013年5月27日 月曜日 午前11時28分
47
SERVICING YOUR GENERATOR
ENGINE OIL CHANGE
Drain the oil while the engine is warm to assure rapid and complete
draining.
1.Turn the engine switch and fuel filler cap vent lever to the OFF
position (see page 25) to reduce the possibility of fuel leakage.
2.Loosen the maintenance cover screw and remove the maintenance
cover (see page 45).
3.Place a suitable container next to the engine to catch the used oil.
4.Remove the oil filler cap, and drain the oil into the container by
tipping the engine toward the oil filler neck.
Improper disposal of engine oil can be harmful to the environment.
If you change your own oil, please dispose of the used oil properly.
Put it in a sealed container, and take it to a recycling center. Do not
discard it in a trash bin, dump it on the ground, or pour it down the
drain.
5.With the engine in a level position, fill with the recommended oil to
the upper limit of the oil filler neck. (see page 48).
Maximum oil capacity: 8 oz (0.25 L)
6.Reinstall the oil fill
er cap securely.
7.Reinstall the maintenance cover and tighten the maintenance cover
scr
ew securely.
Wash your hands with soap and water after handling used oil.
31Z40600.book 47 ページ 2013年5月27日 月曜日 午前11時28分
48
SERVICING YOUR GENERATOR
ENGINE OIL RECOMMENDATIONS
Oil is a major factor affecting performance and service life. Use
4-stroke automotive detergent oil.
SAE 10W–30
is recommended for general use. Other viscosities
shown in the chart may be used when the average temperature in your
area is within the recommended range.
The SAE oil viscosity and service category are in the API label on
the
oil container. Honda recommends that you use API servic
e category SJ
or later (or equivalent) oil.
31Z40600.book 48 ページ 2013年5月27日 月曜日 午前11時28分
49
SERVICING YOUR GENERATOR
AIR CLEANER SERVICE
1.Loosen the maintenance cover
screw and remove the
maintenance cover.
2.Press the latch tab on the top of
the air cleaner case, and remove
the air cleaner cover.
3.Check the foam air filter to be
sure it
is clean and in
good
condition. If the foam air filter is
dirty, clean it as described on
page 50
. Replace the foam air
filter if it is damaged.
4.Reinstall the air filter.
5.Make sure that the rubber seal is
set in the groove of the air
cleaner cover.
6.Reinstall the air cle
aner cover by
inserting the lower tab and the
latch
tab.
7.Reinstall the maintenance cover,
and tigh
ten the ma
intenance
cover screw securely.
Operating the engine without an air filter or with a damaged air filter
will allow dirt to enter the engine, causing rapid engine wear. This type
of damage is not covered by the Distributor’s Limited Warranty.
MAINTENANCE COVER SCREW
MAINTENANCE COVER
AIR CLEANER CASE
FOAM AIR
FILTER
AIR CLEANER
COVER
RUBBER SEAL
LATCH TAB
LOWER TAB
31Z40600.book 49 ページ 2013年5月27日 月曜日 午前11時28分
50
SERVICING YOUR GENERATOR
FOAM AIR FILTER CLEANING
A dirty foam air filter will restrict air flow to the carburetor, reducing
engine performa
nce. If you operate the generator in very dusty areas,
clean the foam air filter more frequently than specified in the
Maintenance Schedule (see page 42).
1. Clean the air filter in warm soapy water, rinse, and allow to dry
thoroughly, or clean in nonflammable
solvent and allow to dry.
2. Dip the air filter in clean engine oil, and then squeeze out all excess
oil. The engine will smoke when started if too much oil i
s left in the
air filter.
3. Remove the rubber air guide from the air cleaner case.
Clean the rubber air guide and the air cleaner case with a moist rag,
then reinstall the rubber air guide.
31Z40601-02.fm 50 ページ 2014年5月23日 金曜日 午後12時52分
51
SERVICING YOUR GENERATOR
SPARK PLUG SERVICE
In order to service the spark plug, you will need a spark plug wrench
(commercially available).
Recommended spark plug: LR4C-E (NGK)
To en
sure proper engine operation, the spark plug must be properly
gapped and free of deposits.
An incorrect spark plug can cause engine damage.
If the engine is hot, allow it to cool before servicing the spark plug.
1.Remove the spark plug maintenance cover.
2.Remove the spark plug cap.
3.Clean any dirt from around the spark plug base.
4.Use a spark plug wrench to remove the spark plug.
31Z40600.book 51 ページ 2013年5月27日 月曜日 午前11時28分
52
SERVICING YOUR GENERATOR
5.Inspect the spark plug. Replace it
if the electrodes are worn or if the
insulator is cracked, chipped, or
fouled.
6.Measure the spark plug electrode
gap with a wire-type feeler
gauge. Correct the gap, if
necessary,
by carefully bending
the side electrode.
The gap sh
ould be:
0.024–0.028 in (0.6–0.7 mm)
7.Make sure that the spark plug sealing washer is in
good condition,
and thread the sp
ark plug in by hand to prevent cross-threading.
8.After the spark plug is seated, tighten with a spark plug wrench to
compress the sealing washer.
If reinstalling a used spark plug, tighten 1/8–1/4 turn after the spark
plug
seats.
If instal
ling a new spark plug, tighten 1/2 turn after the spark plug
seats.
A loose spark plug can overheat and damage the engine.
Overtightening the spark plug can damage the threads in the cylinder
head.
9.Reinstall the spark plug cap on the spark plug securely.
10.Reinstall the spark plug maintenance cover.
SIDE ELECTRODE
0.0240.028 in
(0.60.7 mm)
SEALING WASHER
INSULATOR
31Z40600.book 52 ページ 2013年5月27日 月曜日 午前11時28分
53
SERVICING YOUR GENERATOR
SPARK ARRESTER SERVICE
The spark arrester must be serviced every 100 hours to keep it
functioning as designed.
If the engine has been running, the muffler will be very hot. Allow the
muffler to cool before servicing the spark arrester.
Clean the spark arrester as follows:
1.Remove the four 5 mm screws, and remove the muffler protector.
2.Remove the three 6 mm bolts, and remove the muffler, the spark
arrester,
and the muffler gasket.
31Z40600.book 53 ページ 2013年5月27日 月曜日 午前11時28分
54
SERVICING YOUR GENERATOR
3.Use a brush to remove carbon deposits from the spark arrester
screen.
Be careful to avoid damaging the screen.
The spark arrester must be free of breaks and tears. Replace the
spark arrester if it is damaged.
4.Check the muffler gaske
t; replace if damaged.
Reinstall the muffler gasket, the spark arrester,
the muffler, and the
muffler protector in the reverse order
of removal.
31Z40600.book 54 ページ 2013年5月27日 月曜日 午前11時28分
55
STORAGE
STORAGE PREPARATION
Proper storage preparation is essential for keeping your generator
trouble-free and looking good. The following steps will help to
keep
rust and corrosion from impairing your generator’s function and
appearance, and will make the engine easier to start when you use the
generator again.
Cleaning
Wipe the generator with a moist cloth. After the generator has dried,
touch up any damaged p
aint, and coat other areas that may rust with a
light film of oil.
Fuel
Depending on the region where you operate your equipment, fuel
formulations may deteriorate and oxidize rapidly. Fuel deterioration and
oxidation can occur in as little as 30 days and may cause damage to
the carburetor and/or fuel system. Please check with your servicing
dealer for local storage recommendations.
Gasoline will oxidize and deteriorate in storage. Old gasoline will cause
hard starting, and it leaves gum deposits that clog the fuel system. If
the gasoline in your generator deteriorates during storage, you may
need to have the carburetor and other fuel system components
serviced or replaced.
The length of time that gasoline can be left in your fuel tank and
carburetor
without causing functional problems will vary with such
factors as gasoline blend, your storage temperatures, and whether the
fuel tank is partially or
completely filled. The air in a partially filled fuel
tank promotes fuel deterioration. Very warm storage temperatures
accelerate fuel deterioration. Fuel deterioration problems may occur
within a few months, or even less if the gasoline was not fresh when
you filled the fuel tank.
The Distributor’s Limited Warranty does not cover fuel system damage
or engine performance pro
blems resulting from neglected storage
preparation.
You can extend fuel storage life by adding a gasoline stabilizer that is
formulated for that purpose, or you can
avoid fuel deterioration
problems by draining the fuel tank and carburetor.
31Z40600.book 55 ページ 2013年5月27日 月曜日 午前11時28分
56
STORAGE
Service according to the table below:
STORAGE TIME RECOMMENDED SERVICE PROCEDURE TO
PREVENT HARD STARTI
NG
Less than 1 month No preparation required.
1 to 2 months Fill with fresh gasoline and add gasoline
stabilizer*.
2 months to 1 year Fill with fresh
gasoline and add gasoline
stabilizer*.
Turn the engine switch to the OFF
position and
drain the carburetor float bo
wl (see page 57).
1 year or more Drain the fuel tank and carburetor (see page
58).
Change the engine oil and lubricate the
cylinder (see page 59).
*Use gasoline stabilizers that are
formulated to extend storage life.
Follow the manufacturer’
s instructions for use.
Contact your
authorized Honda generator dealer for stabilizer
recommendations.
31Z40600.book 56 ページ 2013年5月27日 月曜日 午前11時28分
57
STORAGE
Draining the Carburetor
1.Loosen the maintenance cover screw and remove the maintenance
cover (see page 45).
2.Loosen the carburetor drain screw, and drain the gasoline from the
carburetor into a suitable container.
3.Tighten the carbu
retor drain screw.
Gasoline is highly flammable and explosive.
You can be burned or seriously injured when
handling fuel.
Stop the engine and keep
heat, sparks,
and flame away.
Handle fuel o
nly outdoors.
Wipe up spills immediately.
31Z40600.book 57 ページ 2013年5月27日 月曜日 午前11時28分
58
STORAGE
Draining the Fuel Tank and Carburetor
1.Unscrew the fuel filler cap (see page 43), remove the fuel filter, and
empty the fuel tank into an approved gasoline container. We
recommend using a commercially available gasoline hand pump to
empty the tank. Do not use an
electric pump. Reinstall the fuel filter
and the fuel filler cap.
2.Loosen the maintenance cover screw and remove the maintenance
cover (see page 45).
3.Loosen the carburetor drain screw,
and drain the gasoline from the
carburetor into a suitable container.
4.Remove the spark plug maintenance cover, and the spark plug cap
(see page 51).
5.Turn the engine switch to the ON position (see page 23).
6.Pull the starter grip (see page 24) 3 to 4 times to drain the gasoline
from the fuel pump into a suitable container.
7.Turn the engine switch to the OFF position.
8.Tighten the carburetor drain screw.
Gasoline is highly flammable and explosive.
You can be burned or seriously injured when
handling fuel.
Stop the engine and keep
heat, sparks,
and flame away.
Handle fuel o
nly outdoors.
Wipe up spills immediately.
31Z40600.book 58 ページ 2013年5月27日 月曜日 午前11時28分
59
STORAGE
Engine Oil
1.Change the engine oil (see page 47).
2.Remove the spark plug (see page 51), and pour approximately one
teaspoon (5 cc) of clean engine oil into the cylinder. Crank the engine
several revolutions
to distribute the oil, and then reinstall the spark
plug.
3.Reinstall the spark plug cap on the spark plug securely.
4.Reinstall the spark plug maintenance cover.
5.Reinstall the maintenance cover and tighten the maintenance cover
screw securely.
6.
Pull the starter grip (see page 24) slowly until you feel resistance,
and then return the starter grip gently. This closes the valves
so
moisture cannot enter.
31Z40600.book 59 ページ 2013年5月27日 月曜日 午前11時28分
60
STORAGE
STORAGE PRECAUTIONS
If your generator will be stored with gasoline in the fuel tank and
carburetor, it is i
mportant to reduce the hazard of gasoline vapor
ignition.
Select a well ventilated storage area away from any appliance that
operates with a fl
ame, such as a furnace, water heater, or clothes
dryer.
Also avoid any area with a spark-producing electric motor, or where
power tool
s are operated.
If possible, avoid storage areas with hi
gh humidity, because that
promot
es rust and corrosion.
Unless all fuel has been drained from the fuel tank, leave the engine
switch in the OFF posi
tion, and the
fuel filler cap vent lever in the OFF
position (see page 25) to reduce the possibility of leakage.
Place the generator on a level surface. Tilting or laying it on its side can
cause fuel or oil leakage.
With the engine and exhaust system cool, cover the generator to keep
out dust. A hot engine and exhau
st system can ignite or melt some
materials.
Do not use sheet plastic as a dust cover. A nonporous cover will trap
moisture around
the generator, promot
ing rust and corrosion.
REMOVAL FROM STORAGE
Check your generator as described in the BEFORE OPERATION chapter
of this manual (see page 19).
If the fuel was drained during storage
preparation, fill the tank with
fresh gasoline. If you keep a container of gasoline for refueling,
be sure
that it contains only fresh gasoline. Gasoline oxidizes and deteriorates
over time, causing hard starting.
If the cylinder was coated with oil during storage
prep
aration, the
engine may smoke briefly at startup. This is normal.
31Z40600.book 60 ページ 2013年5月27日 月曜日 午前11時28分
61
TRANSPORTING
Do not lay the generator on its side when moving, storing, or operating
it. Oil may leak and damage the engine or your property.
If the generator has been used, allow it cool for at least 15 minutes
before loading the generator on the transport vehicle. A hot engine and
exhaust system can burn you and can ignite some material.
To prevent fuel spillage when transporting, the generator should be
secured upright in its no
rmal operating position, with the engine switch
OFF and the fuel filler cap vent lever turned fully counterclockwise to
the OFF position (see page 25).
Take care not to drop or strike the generator when transporting. Do not
place heavy objects on the generator.
31Z40600.book 61 ページ 2013年5月27日 月曜日 午前11時28分
62
TAKING CARE OF UNEXPECTED PROBLEMS
ENGINE WILL NOT START
Possible Cause Correction
Fuel filler cap vent lever is in
the OFF position.
Turn the fuel filler cap vent lever
to
the ON position (see page 22).
Engine switch is in the OFF
position.
Turn the engine switch to the ON
position (see page 23).
Out o
f fuel. Refuel (see page 43).
Bad fuel, generator stored
without treating or draining
gasolin
e, or refueled with bad
gasoline.
Drain fuel tank and carburetor (see
page 58).
Refuel with fresh gasoline (see page
43).
Low engine oil level cau
sed
Oil Alert to stop engin
e.
Turn the engine switch to the OFF
position. Add engine oil. Then turn the
engine switch to the ON position and
restart the engine.
Spark plug faulty, fouled, or
improp
erly gapped.
Gap or
replace spark plug (see page
51).
Spark plug wet with fuel
(flooded engine
).
Dry and reinstall spark plug.
Fuel filter restricted,
carburetor malfunction,
ignition malfunction, valves
stuck, etc.
Take the generator to an authorized
Honda servicing dealer, or refer to the
shop manual.
31Z40600.book 62 ページ 2013年5月27日 月曜日 午前11時28分
63
TAKING CARE OF UNEXPECTED PROBLEMS
ENGINE LACKS POWER
Possible Cause Correction
Air filter restricted. Clean or replace air filter
(see pages 49, 50).
Bad fuel, generator stored without
treating or drain
ing gasoline, or
refueled with bad gasoline.
Drain fuel tank and carburetor
(see page 58).
Refuel with fresh gasoline (see
page 43).
Fuel filter restricted, carburetor
malfunction, ignition malfunction
,
valves stuck, etc.
Take the generator to an
authorized Honda servicing dealer,
or refer to the shop manual.
31Z40600.book 63 ページ 2013年5月27日 月曜日 午前11時28分
64
TAKING CARE OF UNEXPECTED PROBLEMS
NO POWER AT THE AC RECEPTACLES
NO POWER AT THE DC RECEPTACLE
Possible Cause Correction
Output indicator is OFF, and
overload indicator is ON.
Check AC load. Stop and restart
th
e engine.
Check the cooling
air inlet. Stop
and restart the engine.
Faulty power tool or appliance. Replace or repair power tool or
appliance.
Stop and restart the engine.
Faulty generator. Take the generator to an
authorized Honda servicing dealer,
or refer to the shop manual.
Possible Cause Correction
DC circuit protector is in the OFF
position.
Push the DC circuit protector to
the ON position (see pag
e 35).
Faulty generator. Take the generator to an
authorized Honda servicing dealer,
or refer to the shop manual.
31Z40600.book 64 ページ 2013年5月27日 月曜日 午前11時28分
65
TECHNICAL INFORMATION
Serial Number Location
Record the frame serial number and date purchased in the spaces
below. You will need this information when ordering parts and when
making technical or warranty inquiries.
Frame serial
number:
Date purchased:
31Z40600.book 65 ページ 2013年5月27日 月曜日 午前11時28分
66
TECHNICAL INFORMATION
Carburetor Modification for High Altitude Operation
At high altitude, the standard carburetor air-fuel mixture will be too
rich. Performance will decrease, and fuel consumption will increase. A
very rich mixture wi
ll also foul the spark plug and cause hard starting.
Operation at an altitude that differs from that at which this engine was
certified, for extended periods of time, may increase emissions.
High altitude performance can be improved by specific modifications to
the carburetor. If
you always operate your generator at altitudes above
5,000 feet (1,500 meters), have your authorized Honda servicing
dealer perform this carburetor modification. This engine, when
operated at high altitude with the carburetor modifications for high
altitude use, will meet each emission standard throughout its useful
life.
Even with carburetor modification, engine horsepower will decrease
about 3.5% for each 1,000-foot
(300-meter) increase in altitude. The
effect of altitude on horsepower will be greater than this if no
carburetor modification is made.
When the carburetor has been modified for high altitude operation, the
air/fuel mixture will be too lean for low altitude use. Operation at
altitudes below 5,000 feet (1,500 meters) with a modified carburetor
may cause the engine to overheat and result in serious engine damage.
For use at low altitudes, have your servicing dealer return the
carburetor to original factory specifications.
31Z40600.book 66 ページ 2013年5月27日 月曜日 午前11時28分
67
TECHNICAL INFORMATION
Emission Control System Information
Source of Emissions
The combustion process produces carbon monoxide, oxides of
nitrogen, and h
ydrocarbons. Control of hydrocarbons and oxides of
nitrogen is very important because, under certain conditions, they react
to form photochemical smog when subjected to sunlight. Carbon
monoxide does not react in the same way, but it is toxic.
Honda utilizes appropriate air/fuel ratios and other emissions control
systems to reduce the emissio
ns of carbon monoxide, oxides of
nitrogen, and hydrocarbons.
Additionally, Honda fuel systems utilize components and control
technologies to reduce evaporative emissions.
The U.S. and California Clean Air Acts
EPA and Ca
lifornia regulations require all manufacturers to furnish
written instructions describing
the operation and maintenance of
emission control systems.
The following instructions and procedures must be followed in order to
keep the Honda engine emissions within the emission standards.
Tampering and Altering
Tampering is a violation of Federal and California law.
Tampering with or altering the emission control system may increase
emissions beyond the legal limit. Among those acts that constitute
tampering are:
Removal or alteration of any part of intake, fuel,
or exhaust systems.
A
ltering or defeating the governor linkage or speed-adjusting
mechanism to cause th
e engine to operate outside its design
parameters.
31Z40600.book 67 ページ 2013年5月27日 月曜日 午前11時28分
68
TECHNICAL INFORMATION
Problems That May Affect Emissions
If you are aware of any of the following symptoms, have your engine
inspected and repaired by your authorized Hond
a servicing dealer.
Hard starting or stalling after starting.
Rough idle.
Misfiring or backfiring under load.
Afterburning (backfiring).
Black exhaust smoke or high fuel consumption.
Replacement Parts
The emission control systems on your new Honda engine were
designed, built, and certified
to conform with applicable emission
regulations. We recommend the use of Honda Genuine parts whenever
you have maintenance done. These original-design replacement parts
are manufactured to the same standards as the original parts, so you
can be confident of their performance. The use of replacement parts
that are not of the original design and quality may impair the
effectiveness of your emission control system.
A manufacturer of an aftermarket part assumes the responsibility that
the
part will not adversely affect emission performance. The
manufacturer or
rebuilder of the part must certify that use of the part
will not result in a failure of the engine to comply with emission
regulations.
Maintenance
Follow the M
AINTENAN
CE SCHEDULE on page 42. Remember that
this schedule is based on the assumption that your generator will be
used for it
s designed purpose. Sustained high-load or high-temperature
operation, or use in dusty conditions, will require more frequent service.
31Z40600.book 68 ページ 2013年5月27日 月曜日 午前11時28分
69
TECHNICAL INFORMATION
Air Index
(Models certified for sale in California)
An Air Index Information label is applied to engines certified to an
emission durability time period in accordance with the requirements of
the Cali
fornia Air Resources Board.
The bar graph is intended to provide you, our customer, the ability to
compare the emissions performance of
available engines. The lower the
Air Index, the less pollution.
The durability description is intended to
provide you with information
relating to th
e engine’s emission durability period. The descriptive term
indicates the useful life period for the engine’s emission control
system. See your Emission Control System Warranty (see page 79) for
additional information.
Descriptive Term Applicable to Emission Durability Period
Moderate 50 hours (0–80 cc, inclusive)
125 hours (greater than 80 cc)
Intermediate 125 hours (0–80 cc, inclusive)
250 hours (greater than 80 cc)
Extended 300 hours (0–80 cc, inclusive)
500 hours (greater than 80 cc)
1,000 hours (225 cc and greater)
31Z40600.book 69 ページ 2013年5月27日 月曜日 午前11時28分
70
TECHNICAL INFORMATION
Specifications
Dimensions
Engine
Generator
Tuneup Specifications
Specifications are subject to change without notice.
Model EU1000i
Description code EAAT
Length 17.8 in (451 mm)
Width 9.5 in (242 mm)
Height 14.9 in (379 mm)
Dry mass [weight] 29 lbs (13 kg)
Model GXH50
Engine type 4-stroke, overhead valve, single cylinder
Displacement
[Bore×Stroke]
3.01 cu-in (49.4 cm
3
)
[1.65×1.42 in (41.8×36.0 mm)]
Compression ratio 8.0:1
Engine speed 5,500–6,000 rpm
(with Eco-Throttle switch OFF)
Cooling system Forced air
Ignition system Full transistor
Engine oil capacity 8 oz (0.25 L)
Fuel tank capacity 0.55 US gal (2.1 L)
Spark plug LR4C-E (NGK)
Model EU1000i
Type A type
AC
output
Rated Voltage 120 V
Rated Frequency 60 Hz
Rated Current 7.5 A
Rated Output 0.9 kVA
Maximum Output 1.0 kVA
DC output Only for charging 12 V automotive batteries.
Maximum changing output = 8 A
ITEM SPECIFICATION MAINTENANCE
Spark plug gap 0.024–0.028 in
(0.6–0.7 mm)
Refer to page 51.
Valve clearance
(cold)
IN: 0.08±0.02 mm
EX: 0.11±0.02 mm
See your authorized
Honda dealer.
Other specifications No other adjustments needed.
31Z40600.book 70 ページ 2013年5月27日 月曜日 午前11時28分
71
TECHNICAL INFORMATION
Wiring Diagram
R
MAIN
WINDING
SUB
WINDING
INVERTER
UNIT
DC
WINDING
EXCITER
WINDING
SPARK
PLUG
IGNITION
COIL
ENGINE
GROUND
IGNITION
PULSE
GENERATOR
IGNITION
SWITCH
THROTTLE
CONTROL
MOTOR
RECTIFIER
OIL
LEVEL
SWITCH
W
Bu
Gr
P
W
R
Y
Bu
W
R
Y
Bu
YY
Bu
G
G
G
BlBl
Br
Bl/Bu
Br
W/R
Bl/R
G
G
Bu
Bl/Bu
Bl
Y
G
Bu
Bl/Bu
Bl
Y
Bl
G
Bl
G
R/W
G/R
G/Bl
PILOT
LAMP
OVERLOAD
INDICATOR
Y
G
G
R
R
Bl
Bl/Bu
Bu
R/W
R
G
R
R/Y
R/W
W/R
Bl/R
R/Y
G/R
G/Bl
ENGINE BLOCK
FRAME BLOCK
CONTROL PANEL BLOCK
INVERTER BLOCK
GENERATOR BLOCK
DC OUTLET
RECEPTACLE
FRAME
GROUND
SPARK UNIT
ECO-THROTTLE
SWITCH
PARALLEL
OUTLETS
AC OUTPUT
RECEPTACLE
GROUND
TERMINAL
OIL ALERT
LIGHT
BLACK
YELLOW
BLUE
GREEN
RED
WHITE GRAY
PINK
LIGHT GREEN
SKY BLUE
ORANGE
BROWN
W
R
G
Bu
Y
Bl
Gr
P
Lg
SB
O
Br
COLOR COMB : GROUND/MARKING
Switch position
ON OFF
OFF ON
ECO-
THROTTLE
31Z40600.book 71 ページ 2013年5月27日 月曜日 午前11時28分
72
CONSUMER INFORMATION
Dealer Locator Information
To find an authorized Honda Servicing Dealer anywhere in the United
States:
Visit our website:
http://powerequipment.honda.com/dealer-locator
Honda Publications
Shop Manual
This manual co
vers complete maintenance and overhaul procedures.
It is intended to be used by a skilled technician.
Available through your Honda dealer or visit
http://powerequipment.honda.com/support/shop-manuals
Parts Catalog
This manual provides complete, illustrated parts lists. Available through
your Honda dealer.
Accessories Catalog
Your au
thorized Honda power equipment dealer offers a wide selection
of accessori
es (optional equipment) to make your generator
even more
useful.
Visit http://powerequipment.honda.com/generators/accessories
and click on Generators and Wel
ders to see the entire catalog of
accessories.
31Z40600.book 72 ページ 2013年5月27日 月曜日 午前11時28分
73
CONSUMER INFORMATION
Customer Service Information
Honda Power Equipment dealership personnel are trained professionals.
They should be able to answer any question you may have. If you
encounter a problem that your dealer does not solve to your
satisfaction, please discuss it with the dealership’s management.
The Service Manager or General Manager can help. Almost all problems
are solved in this way.
If you are dissatisfied with the decision made
by the dealership’s
management, cont
act the Honda Power Equipment Customer Relations
Office. You can write:
American Honda Motor Co., Inc.
Power Equipment Division
Customer Relations Office
4900 Marconi Drive
Alpharetta, Georgia 30005-8847
Or telephone: (770) 497-6400 8:30 am to 7:00 pm ET
When you write or call, please give us this information:
Model and serial numbers (see page 65)
Name of the dealer who sold the generator to you
Name and address of the dealer who services your generator
Date of purchase
Your name, address, and telephone number
A detailed description of the problem
31Z40600.book 73 ページ 2013年5月27日 月曜日 午前11時28分
74
CONSUMER INFORMATION
Distributor’s Limited Warranty
This warranty is limited to the following Ho
nda Power Equipment
products when distributed by American Honda Motor Co., Inc., Power
Equipment Division, 4900 Marconi Drive, Alpharetta, Georgia
30005-8847. The following warranty applies to products purchased at
retail or placed in rental service on or after January 1,
2010.
(1) Private residential: Used in maintaining owner’s primary and/or
secondary residence. Any other use, including but not limited to
informal ‘‘for hire’’ use, is considered commercial
/rental/
institutional use.
To Qualify for this Warranty:
The product must be purchased in the United States, Puerto Rico, or
the U.S. Virgin Islands from American
Honda or a dealer authorized by
American Honda to sell those products. This warranty applies to the
first retail purchaser and each subsequent owner during the applicable
warranty time period.
What American Honda will Repair or Replace Under Warranty:
American Honda will repair or replace, at its option, any part that is
proven to be
defective in material or
workmanship under normal use
during the applicable warranty time period. Warranty repairs and
replacements will be made without charge for parts or labor. Anything
replaced under warranty becomes the property of American Honda
Motor Company, Inc. All parts replaced under warranty will be
considered as part of the original product, and any warranty on those
parts will expire coincident with the original product warranty.
PRODUCTS COVERED
BY THIS WARRANTY
LENGTH OF WARRANTY
(from date of original retail purchase)
PRIVATE
RESIDENTIAL (1)
COMMERCIAL/
RENTAL/INSTITUTIONAL
EU1000i generator 24 months 12 months
The Parts & Accessories warranty is on page 77.
31Z40600.book 74 ページ 2013年5月27日 月曜日 午前11時28分
75
CONSUMER INFORMATION
To Obtain Warranty Service:
You must, at your expense, take the Honda Power Equipment product,
accessory, replacement part, apparel, or the power equipment on
which the accessory or replacement part is installed, and proof of
purchase to any Honda Power Equipment dealer in the United States,
Puerto Rico, or the U.S. Virgin Islands who is authorized to sell that
product, during the dealer’s normal business hours. To locate a dealer
near you, visit our web site at http://powerequipment.honda.com/
dealer-locator/. If you are unable to obtain warranty service or are
dissatisfied with the warranty service you receive, contact the owner
of the dealership involved; normally this will resolve the problem.
However, if you should require further assistance, write or call the
Power Equipment Customer Relations Dept. of American Honda Motor
Co., Inc. at the following address:
American Honda Motor Co., Inc.
Power Equipment Customer Relatio
ns Dept.
4900 Marconi Drive
Alpharetta, GA 30005-8847 Telephone: (770) 497-6400
31Z40600.book 75 ページ 2013年5月27日 月曜日 午前11時28分
76
CONSUMER INFORMATION
Exclusions:
1.Any damage or deterioration resulting from the following:
Neglect of the periodic maintenance as specified in this manual
Improper repa
ir or maintenance
Operating methods other than those indicated in this manual
The use of non-genuine Honda parts and accessories other than
those approved by Honda (other than recommended lubricants and
fluids)
Exposure of the product to soot and smoke, chemical agents, bird
droppings, sea water, sea breeze, salt or other environmental
phenomena
– Collision, fuel contamination or deterioration, neglect, unauthorized
alteration, misuse, incorporation or use of unsuitable attachments
or parts
– Natural wear and tear (natural fading of painted or plated surfaces,
sheet peeling and other natural deterioration)
2.Consumable parts: Honda does not warrant parts deterioration due
to natural wear and tear. The parts listed below are not
covered by
warranty (unless they are needed as a part of another warranted
repair):
Spark plug, fuel filter, air cleaner element, clutch disc, tire, wheel
bearing, recoil starter rope, cable,
belt, cutter blade.
Lubricant: oil and grease.
3.Cleaning, adjustment, and normal periodic maintenance work
(carburetor cleaning, engine oil draining, blade sharpening, belt and
cable adjustments).
4.Any product that has ever been declared a total loss or sold for
salvage by a financial institution or insurer.
5.Auger and paddle assemblies of snowthrowers, tiller tines of
rototillers, mower blades and mower deck housings, are specifically
not warranted agains
t impact damage, including but not limited to,
abrasive damage.
Disclaimer of Consequential Damage and Limitation of Implied
Warranties:
American Honda disclaims any responsibility for loss of time or use of
the product,
transportation, commercial loss, or any other incidental or
consequential damage. Any implied warranties are limited to the
duration of this written limited warranty. Some states do not allow
limitations on how long an implied warranty lasts and/or do not allow
the exclusion or limitation of incidental or consequential damages, so
the above exclusions and limitations may not apply to you. This
warranty gives you specific legal rights, and you may also have other
rights which vary from state to state.
31Z40600.book 76 ページ 2013年5月27日 月曜日 午前11時28分
77
CONSUMER INFORMATION
Honda Accessories, Replacement Parts, And Apparel
This warranty is limited to Honda Power Equipm
ent parts, accessories,
and apparel when distributed by American Honda Motor Co., Inc.,
4900 Marconi Drive, Alpharetta, Georgia 30005-8847.
To Qualify for This Warranty:
1.The accessories, replacement parts, or apparel must be purchased
from American Honda, or a deal
er, distributor, or distributor’s dealer
authorized by American Honda to sell those products in the United
States, Puerto Rico, and the U.S. Virgin Islands. Parts and
Accessories must be purchased for installation on original Honda
equipment or engines to be eligible for warranty coverage. Installing
parts and accessories on non-
Honda products or engines voids this
warranty.
2.You must be the first retail purchaser. This warranty is not
transferable to subsequent
owners.
What American Honda Will Repair or Replace Under Warranty:
American Honda will repair or replace, at its option, any Honda Power
Equipment accessories, replacement parts, or apparel that are proven
to be defective in material or workm
anship under normal use during the
applicable warranty time period. Anything replaced under warranty
becomes the property of American Honda Motor Company, Inc. All
parts replaced under warranty will be considered as part of the original
product, and any warranty on those parts will expire coincident with
the original product warranty.
Accessories and replacement parts installed by a dealer, distributor, or
distributor’s d
ealer who is authorized by American Honda to sell them
will be repaired or replaced under warranty without charge for parts or
labor. If installed by anyone else, accessories and replacement parts
will be repaired or replaced under warranty without charge for parts,
but any labor charges will be the responsibility of the purchaser.
Apparel will be repaired or replaced under warranty without any
charge.
PRODUCTS COVERED
BY THIS WARRANTY
LENGTH OF WARRANTY
(from date of original retail purchase)
PRIVATE
RESIDENTIAL
COMMERCIAL/
RENTAL/INSTITUTIONAL
Accessories 12 months 3 months
Replacement parts 6 months 3 months
Apparel 6 months 3 months
31Z40600.book 77 ページ 2013年5月27日 月曜日 午前11時28分
78
CONSUMER INFORMATION
To Obtain Warranty Service:
You must, at your expense, take the Honda Power Equipment
accessory, replacement part, apparel, or the Honda Power
Equipment
on which the accessory or replacement part is installed, and proof of
purchase to any Honda Power Equipment dealer, distributor, or
distributor’s dealer in the United States, Puerto Rico, or the U.S. Virgin
Islands who is authorized to sell that product, during the dealer’s or
distributor’s normal business hours. To locate a dealer near you, go to
our web site at http://powerequipment.honda.com/dealer-locator/. If
you are unable to obtain warranty service or are dissatisfied with the
warranty service you receive, contact the owner of the dealership or
distributorship involved; normally this will resolve the problem.
However, if you should require further assistance, write or call the
Power Equipment Customer Relations Department of America Honda
Motor Co., Inc. Refer to page 75 for contact information.
Exclusions:
This warranty does not extend to accessories, parts, or apparel
affected
or damaged by collision, normal wear
, use in an application for
which the product was not designed or any other misuse, neglect,
incorporation or use of unsuitable attachments or parts, unauthorized
alteration, improper installation, or any causes other than defects in
material or workmanship of the product. Installing Parts and
Accessories on non-Honda products or engines voids this warranty.
Disclaimer of Consequential Damage and Limitation of Implied
Warranties:
American Honda disclaims any responsibility for loss of time or use of
the product, or the p
ower equipment on which the product is installed,
transportation, commercial loss, or any other incidental or
consequential damage. Any implied warranties are limited to the
duration of this written warranty. Some states do not allow limitations
on how long an implied warranty lasts and/or do not allow the
exclusion or limitation of incidental or consequential damages, so the
above exclusions and limitations may not apply to you. This warranty
gives you specific legal rights, and you may also have other rights
which vary from state to state.
31Z40600.book 78 ページ 2013年5月27日 月曜日 午前11時28分
79
CONSUMER INFORMATION
Emission Control System Warranty
Your new Honda Power Equipment engine complies with the U.S. EPA,
Environment Canada, and State of California emission regulations
(models certified for sale in California only). American Honda Motor
Co., Inc. provides the emission warranty coverage for engines in the
United States and its territories. Honda Canada Inc. provides the
emission warranty for engines in the 13 provinces and territories of
Canada. In the remainder of this Emission Control System Warranty,
American Honda Motor Company Inc. and Honda Canada Inc. will be
referred to as Honda.
Your Warranty Rights And Obligations:
California
The California Air Resources Board and Honda are pleased to explain
the emission control
system warranty on your 2013 and later Honda
Power Equipment engine. In California, new spark-ignited small off-road
equipment engines must be designed, built, and equipped to meet the
State’s stringent anti-smog standards.
Other States, U.S. territories, and Canada
In other areas of the United States and in Canada, your engine must be
designe
d, built, and eq
uipped to meet the U.S. EPA and Environment
Canada emission standards for spark-ignited engines at or below 19
kilowatts. Specific Honda products that do not meet the California
emissions regulations can be identified by a ‘‘Not for sale in California’’
decal.
All of the United States and Canada
Honda must warrant the emission control system on your power
equipment engine fo
r the period of time listed below, provided there
has been no abuse, neglect, or improper maintenance of your power
equipment engine. Where a warrantable condition exists, Honda will
repair your power equipment engine at no cost to you including
diagnosis, parts, and labor.
Your emission control system may include such parts as the carburetor
or fuel injection system, the ignition system, and catalytic converter.
Also inclu
ded may be hoses, connectors, and other emission-related
assemblies (see page 83 for additional covered parts).
31Z40600.book 79 ページ 2013年5月27日 月曜日 午前11時28分
80
CONSUMER INFORMATION
Owner’s Warranty Responsibility:
As the power equipment engine owner, you are responsible for the
performance of th
e required maintenance listed in your owner’s
manual. Honda recommends that you retain all receipts covering
maintenance on your power equipment engine, but Honda cannot deny
warranty coverage solely for the lack of receipts or for your failure to
ensure the performance of all scheduled maintenance.
As the power equipment engine owner, you should however be aware
Hon
da may deny you w
arranty coverage if your power equipment
engine or a part has failed due to abuse, neglect, improper
maintenance, or unapproved modifications.
You are responsible for presenting your power equipment engine to a
Honda Power
Equipment dealer as soon as a problem exists. The
emission related warranty repairs should be completed in a reasonable
amount of time, not to exceed 30 days.
If you have any questions regarding your emission warranty rights and
responsibilities, you should contact the Honda office in your region:
American H
onda Motor Co., Inc. Honda Canada Inc.
Power Equipment Customer Power Equipment
Relations Customer Relations
4900 Marconi Drive or 180 Honda Blvd,
Alpharetta, Georgia 30005-8847 Markham, ON L6C 0H9
Telephone: (888) 888-3139 Telephone: (888) 946-6329
Email: powerequipmentemissions
@ahm.honda.com
31Z40600.book 80 ページ 2013年5月27日 月曜日 午前11時28分
81
CONSUMER INFORMATION
Warranty Coverage:
Honda power equipment engines sold in the United States and Canada
are covered by this warranty for a period of two years from the date of
delivery to the original retail purchaser or the length of the Honda
Distributor’s Limited Warranty, whichever is longer. This warranty is
transferable to each subsequent purchaser for the duration of the
warranty period.
If any emission-related part on your engine is
defective, the part will be
repaired or replaced by Honda without
charge for diagnosis, parts, or
labor. All defective parts replaced under this warranty become the
property of Honda. A list of warranted parts is on page 83. Normal
maintenance items, such as spark plugs and filters, that are on the
warranted parts list are warranted up to their required replacement
interval only.
Honda will also replace other engine
components damaged by a failure
of any warranted part during
the warranty period.
Only Honda-approved replacement parts may be used in the
performa
nce of any warranty repairs and must be provided without
charge to the owner. The use of replacement parts not equivalent to
the original parts may impair the effectiveness of your engine emission
control system. If such a replacement part is used in the repair or
maintenance of your engine, and an authorized Honda dealer
determines it is defective or causes a failure of a warranted part, your
claim for repair of your engine may be denied. If the part in question is
not related to the reason your engine requires repair, your claim will not
be denied.
31Z40600.book 81 ページ 2013年5月27日 月曜日 午前11時28分
82
CONSUMER INFORMATION
To Obtain Warranty Service:
You must, at your own expense, take your Honda Power Equipment
engine or the product on
which it is installed, along with your sales
registration card or other proof of original purchase date, to any Honda
Power Equipment dealer who is authorized by Honda to sell and service
that Honda product during his normal business hours. Claims for repair
or adjustment found to be caused solely by defects in material or
workmanship will not be denied because the engine was not properly
maintained and used.
If you are unable to obtain emission warranty servi
ce or are dissatisfied
with the warranty service you received, contact the owner of the
dealership
involved. Normally this should resolve your problem.
However, if you require further assistance, contact the Honda office in
your region:
American Honda Motor Co., Inc. Honda Canada Inc.
Power Equipment Customer Power Equipment
Relations Customer Relations
4900 Marconi Drive or 180 Honda Blvd,
Alpharetta, Georgia 30005-8847 Markham, ON L6C 0H9
Telephone: (888) 888-3139 Telephone: (888) 946-6329
Email: powerequipmentemissions
@ahm.honda.com
Exclusions:
Failures other than those resulting
from defects in material o
r
workmanship are not covered by this warranty. This warranty does not
extend to emission control systems or parts that are affected or
damaged by owner abuse, neglect, improper maintenance, misuse,
misfueling, improper storage, collision, the incorporation of, or use of,
unsuitable attachments, or the unauthorized alteration of any part.
This warranty does not cover replacement of expendable maintenance
items made in connection with required maintenance service after the
item
’s first scheduled replacement as listed in the maintenance section
of the product owner’s manual, such as: spark plugs and filters.
31Z40600.book 82 ページ 2013年5月27日 月曜日 午前11時28分
83
CONSUMER INFORMATION
Disclaimer of Consequential Damage and Limitation of Implied
Warranties:
American Honda Motor Co., Inc. and Honda Canada Inc. disclaim any
responsibility for incidental or consequential damages such as loss of
time or the use of the power equipment, or any commercial loss due to
the failure of the equipment; and any implied warranties are limited to
the duration of this written warranty. This warranty is applicable only
where the California, U.S. EPA, or environment Canada emission
control system warranty regulation is in effect.
Emission Control System Warranty Parts:
Note: This list applies to parts supplied by Honda and does not cover
parts
supplied b
y the equipment manufacturer. Please see the original
equipment manufacturer’s emissions warranty for non-Honda parts.
*Covered up to the first required replacement only.
See the MAINTENANCE SCHEDULE on page 42.
SYSTEMS COVER
ED
BY THIS WARRANTY:
PARTS
DESCRIPTION:
Fuel
Metering Carburetor assembly (includes starting
enrichment system),
Engine temperature sensor,
Engine control module, Fuel Injector,
Fuel regulator, Intake manifold
Evaporative Fuel tank, Fuel cap, Fuel hoses,
Vapor hoses, Carbon canister,
Canister mounting brackets,
Fuel strainer, Fuel valve, Fuel pump,
Fuel hose joint, Canister purge hose joint
Exhaust Catalyst, Exhaust pipe, Muffler (with catalyst)
Air Induction Air cleaner case, Air cleaner element*
Ignition Flywheel comp., Flywheel magneto, Ignition
pulse generator, Crankshaft position sensor,
Power coil, Ignition coil assembly,
Ignition control module, Spark plug cap,
Spark plug*
Crankcase Emission
Control
Crankcase breather tube, Breather valve
assembly, Oil filler cap
Miscellaneous Parts Tubing, fittings, seals, gaskets,
and clamps associated with these listed
systems.
31Z40600.book 83 ページ 2013年5月27日 月曜日 午前11時28分
84
INITIAL USE INSTRUCTIONS
ENGINE OIL
The generator is shipped WITHOUT OIL in the engine.
1.Place the generator on a level surface.
2.Loosen the maintenance cover screw and remove the maintenance
cover.
3.With the generator in a level position, remove the oil filler cap.
4.Add enough SAE 10W-30 API service category SJ or later (or
equivalent) oil to bring
the oil level to the upper limit of the oil filler
neck. SAE 10W-30 oil is recommended for general use; for addi
tional
recommendations, see page 48.
Maximum oil capacity: 8 oz (0.25 L)
Do not overfill the engine with
oil. If the engine is overfilled,
the
excess oil may be transferred to the air cleaner case and air filter.
5.Screw in the oil filler cap securely.
6.Reinstall the maintenance cover and tighten the maintenance cover
screw securely.
31Z40600.book 84 ページ 2013年5月27日 月曜日 午前11時28分
85
INITIAL USE INSTRUCTIONS
FUEL
Add fuel to the generator in a well-ventilated area. Never refuel the
engine inside a building where gasoline fumes may reach flames or
sparks. Keep gasoline away from appliance pilot lights, barbecues,
electric appliances, power tools, etc. Spilled fuel is not only a fire
hazard, it causes environmental damage. Wipe up spills immediately.
This engine is certified to operate on unleaded gasoline with a pump
octane rating of 86 or
higher. Refer to page 44 for additional fuel
recommendations.
Gasoline is highly flammable and explosive.
You can be burned or seriously injured when
handling fuel.
Stop the engine and keep
heat, sparks,
and flame away.
Handle fuel o
nly outdoors.
Wipe up spills immediately.
31Z40600.book 85 ページ 2013年5月27日 月曜日 午前11時28分
86
INITIAL USE INSTRUCTIONS
1.Remove the fuel filler cap.
2.Fuel carefully to avoid spilling
fuel. Do not
fill the fuel tank
above the upper limit mark (red)
on the fuel filter.
Fuel can damage paint and plastic. Be careful not to spill fuel when
filling your fuel tank. Damage caused by spilled fuel is not covered
under warranty.
3.After refueling, tighten the fuel filler cap securely. Keep the fuel filler
cap vent lever OFF for storage or transport, and ON to run the
generator.
FUEL FILLER CAP
UPPER LIMIT MARK (RED)
FUEL FILTER
31Z40600.book 86 ページ 2013年5月27日 月曜日 午前11時28分
87
INITIAL USE INSTRUCTIONS
Move the generator at least 10 feet (3 meters) away from the fueling
source and site before starting the engine.
After initial fueling (or anytime the generato
r is
run completely out of
fuel), starting the engine may require additional pulls of the starter grip.
This generator utilizes a vacuum operated fuel pump and may require
additional pulls to draw fuel into the carburetor.
BEFORE OPERATION
Before using the generator, all generator operators must read the
following chapters and sections:
•GE
NERATOR SAFETY (see pages 6–10
)
CONTROLS & FEATURES (see pages 1118
)
BEFORE OPERATION (see pages 1920
)
•OPERATION (see page 21)
STARTING THE ENGINE (see pages 2224)
STOPPING THE ENGINE (see pages 2526
)
MAINTENANCE SCHEDULE (see page 42)
REGISTRATION
Please Register Your Generator
If your dealer did not collect registration information from
you, please
take a few minutes and register your purchase with Honda. This allows
us to contact you with any important updates regarding your
generator. Please note registration is not required to obtain warranty
service. You can register your generator by visiting the Honda Power
Equipment website, http://powerequipment.honda.com and selecting
Product Registration. Your information will remain confidential. It will
not be released to any other company or organization.
31Z40600.book 87 ページ 2013年5月27日 月曜日 午前11時28分
88
INDEX
A
AC Applications .................................................................... 29
AC OPERATION .................................................................... 27
AC PARALLEL OPERATION .................................................... 30
AC Parallel Operation Applications........................................... 32
AIR CLEANER SERVICE.......................................................... 49
Air Index .............................................................................. 69
ARE YOU READY TO GET STARTED?...................................... 19
B
BEFORE OPERATION ....................................................... 19, 87
C
Carbon Monoxide Hazards ........................................................ 6
Carburetor Modification for High Altitude Operation
...........
........ 66
Check the Engine .................................................................. 20
Choke Lever ......................................................................... 14
Cleaning............................................................................... 55
COMPONENT & CONTROL LOCATIONS................................... 11
Connections to a Building’s Electrical System
....
.....
.....
............. 38
CONSUMER INFORMATION.................................................... 72
CONTENTS ............................................................................ 3
CONTROLS .......................................................................... 13
CONTROLS & FEATURES....................................................... 11
Customer Service Information ................................................. 73
D
DC Circuit Protector .............................................................. 16
DC OPERATION .................................................................... 34
DC Receptacle ...................................................................... 16
Dealer Locator Information ..................................................... 72
Distributor’s Limited Warranty................................................. 74
31Z40600.book 88 ページ 2013年5月27日 月曜日 午前11時28分
89
INDEX
E
Eco-Throttle Switch ............................................................... 15
ECO-THROTTLE SYSTEM....................................................... 37
Electric Shock Hazards............................................................. 7
Emission Control System Information....................................... 67
Emission Control System Warranty .......................................... 79
ENGINE LACKS POWER ......................................................... 63
Engine Oil....................................................................... 59, 84
ENGINE OIL CHANGE ............................................................ 47
ENGINE OIL LEVEL CHECK ..................................................... 45
ENGINE OIL RECOMMENDATIONS ..............
............................ 48
Engine Switch....................................................................... 13
ENGINE WILL NOT START...................................................... 62
F
FEATURES ........................................................................... 17
Fire and Burn Hazards .............................................................. 7
FOAM AIR FILTER CLEANING ................................................. 50
Fuel ............................................................................... 55, 85
Fuel Filler Cap Vent Lever....................................................... 14
FUEL RECOMMENDATIONS.................................................... 44
G
GENERATOR SAFETY .............................................................. 6
Ground Terminal ................................................................... 18
H
Honda Publications ................................................................ 72
I
IMPORTANT SAFETY INFORMATION ........................................ 6
INITIAL USE INSTRUCTIONS .................................................. 84
IS YOUR GENERATOR READY TO GO? .................................... 19
K
Knowledge ........................................................................... 19
31Z40600.book 89 ページ 2013年5月27日 月曜日 午前11時28分
90
INDEX
M
MAINTENANCE SAFETY ........................................................ 41
MAINTENANCE SCHEDULE .................................................... 42
N
NO POWER AT THE AC RECEPTACLES ................................... 64
NO POWER AT THE DC RECEPTACLE ..................................... 64
O
Oil Alert Indicator .................................................................. 18
OPERATION.......................................................................... 21
Operator Responsibility ............................................................ 6
Output Indicator.................................................................... 17
Overload Indicator ................................................................. 17
P
Parallel Operation Outlets ....................................................... 15
Q
QUICK REFERENCE INFORMATION ..................... Inside back cover
R
REFUELING........................................................................... 43
Refuel With Care ..................................................................... 8
REGISTRATION..................................................................... 87
REMOVAL FROM STORAGE ................................................... 60
31Z40600.book 90 ページ 2013年5月27日 月曜日 午前11時28分
91
INDEX
S
SAFE OPERATING PRECAUTIONS ........................................... 21
SAFETY LABEL LOCATIONS..................................................... 9
Safety Precautions ................................................................ 41
Serial Number Location .......................................................... 65
SERVICING YOUR GENERATOR .............................................. 40
SPARK ARRESTER SERVICE ................................................... 53
SPARK PLUG SERVICE........................................................... 51
Special Requirements............................................................. 39
Specifications ....................................................................... 70
STANDBY POWER................................................................. 38
Starter Grip .......................................................................... 13
STARTING THE ENGINE ......................................................... 22
STOPPING THE ENGINE ......................................................... 25
STORAGE ............................................................................ 55
STORAGE PRECAUTIONS ...................................................... 60
STORAGE PREPARATION....................................................... 55
System Ground ..................................................................... 38
T
TAKING CARE OF UNEXPECTED PROBLEMS............................ 62
TECHNICAL INFORMATION.................................................... 65
THE IMPORTANCE OF MAINTENANCE .................................... 40
TRANSPORTING ................................................................... 61
W
Wiring Diagram ..................................................................... 71
31Z40600.book 91 ページ 2013年5月27日 月曜日 午前11時28分
92
MEMO
31Z40600.book 92 ページ 2013年5月27日 月曜日 午前11時28分
QUICK REFERENCE INFORMATION
Fuel Type Regular unleaded gasoline with an
ethanol content of no more than
10% and a pump octane rating of
86 or higher
Engine Oil Type SAE 10W-30, API SJ or later (or
equivalent), for general use
(see page 48)
Maximum oil capacity:
8 oz (0.25 L)
Spark Plug Type NGK: LR4C-E
Electrode Gap 0.024–0.028 in (0.6–0.7 mm)
Maintenance Before each
use
Check engine oil level
Check air filter
First 10 hours Change engine oil
Subsequent See MAINTENANCE SCHEDULE
(see page 42)
31Z40600.book 93 ページ 2013年5月27日 月曜日 午前11時28分
Printed in Thailand
31Z40601
00X31-Z40-6010
2013 Honda Motor Co., Ltd. -All Rights Reserved
GENERATOR
EU1000i
Owner’s Manual
See page 84 for
Initial Use Instructions
H i
FM
C
AH
74

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Honda EU1000i bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Honda EU1000i in de taal/talen: Engels als bijlage per email.

De handleiding is 4,92 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info