SELECT OPERATION MODE
Pressing the changeover switch allows the selection of
rotation speed and the auto stop function.
Rotation speed (Low mode/Normal mode) (Fig. 17)
Select either Low mode or Normal mode and operate the
tool in the selected speed.
Auto stop mode (on/o ) (Fig. 18)
This product is equipped with an auto stop function to
support continuous drilling work. The function features a
memory mode for storing the work time for drilling from
switch ON to switch OFF, and an auto stop mode that
automatically stops the motor from the second drilling
onward should the work exceed the stored work time
while the switch is ON.
AUTO STOP FUNCTION
In selection mode, pressing the button for longer than two
seconds will move to memory mode. (Fig. 18)
(At the same time the auto stop lamp will blink.)
Conduct drilling when the auto stop lamp is ashing. The
time between switching ON and switching OFF is stored by
the tool.
(At the same time, the auto stop lamp will light up.)
Conduct drilling when the auto stop lamp is ashing.
Continuous drilling is possible as the memory storage time
will be recorded by the tool until the auto stop function’s auto
stop mode is cancelled.
The auto stop function is cancelled by pressing the
changeover switch once again for over two seconds.
(At the same time, the auto stop lamp will switch o .)
CAUTION
Switch ON the tool once you place the tip of the tool on
the work material.
The rotation speed and the level at which the switch is
pulled during drilling is not stored to memory.
Fully carry out drilling in one go during auto stop mode.
The motor will stop even if you switch OFF within the
memory storage time.
When you switch OFF within the memory storage time,
the count will be reset. If you rework a task in which a
hole has been partially drilled, the memory storage time
will be fully recounted.
The auto stop function will remain active until canceled.
REACTIVE FORCE CONTROL
This product is equipped with a Reactive Force Control
(RFC) feature that reduces jerking of the tool body.
If the tool bit is suddenly overburdened, any jerking of the
tool body is reduced by activation of the slip clutch or by
stopping of the motor by the sensor built into the tool body.
If the motor is stopped because of overburdening detection
by the controller, the display lamp will blink while the switch
is pulled. In addition, the lamp will continue blinking for
approximately three seconds after the switch is released.
The motor will remain stopped while the lamp is blinking.
(Fig. 26)
Because the RFC feature may not activate or its performance
may be insu cient depending on the working environment
and conditions, be careful not to suddenly overburden the
tool bit while operating.
Possible causes of sudden overburdening
Tool bit biting into material
Impact against nails, metal or other hard objects
Tasks involving prying or any excess application of
pressure, etc.
Also, other causes include any combination of the
aforementioned.
When the reactive force control (RFC) is triggered
When the RFC is triggered and the motor stops, turn
o the tool’s switch and remove the cause of the
overburdening before continuing operation.
Fig. 26
LED LEVEL FUNCTION
The LED level function uses a red or green LED to indicate
whether the tool is horizontal or vertical.
1. To turn on the LED level function during use, pull the
switch trigger gently. Press the level LED switch when
the display lamp on the panel lights up. (Fig. 1)
2. The level LED on the tool side lights up or blinks in the
color shown below when the level LED switch is pressed.
(Fig. 19)
Green lights: Within 5° of horizontal or vertical
Green blinks: Within 5°–10° of horizontal or vertical
Red lights: Not within 10° of horizontal or vertical
CAUTION
This function does not work while drilling holes (while the
trigger switch is pulled). Use it to check tilting of the tool
before or after drilling.
The angle is approximate.
3. Press the level LED switch once again to turn it o .
The previous settings will be retained once it is turned
back on again.
CAUTION
This function indicates vertical and horizontal directions
with respect to gravity and does not indicate whether the
tool is perpendicular to surfaces that may be at an angle.
The LED level function detects tilt for surfaces (such
as walls) that are perpendicular with respect to gravity
(Fig. 19-a (43) (44)), but it cannot detect horizontal
tilting with respect to the surfaces (Fig. 19-b (45) (46)).
0000BookDH3628DA.indb150000BookDH3628DA.indb15 2022/12/0915:14:272022/12/0915:14:27
15

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Hikoki DH3628DC bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Hikoki DH3628DC in de taal/talen: Alle talen als bijlage per email.

De handleiding is 17.27 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info