INSTALLATION
GENERAL INSTRUCTION
The appliance described in this manual has been built to meet 2014/35/EU (Safety), 2014/30/EU (EMC), Re 2016/426/EU
(GAR), Re 1935/2004/EC, Re 2023/2006/EC directives; and UNI EN 203…, UNI EN 437, EN 60335-1, EN60335-2-36 and
EN55014 standards. This appliance has been designed exclusively for cooking food, any other use is considered improper: be
careful that no live animal, person or “dangerous” objects are placed inside the oven. It should only be used by qualified
personnel in professional kitchens. Materials in contact with foodstuffs are suitable for use. The unit must never be left
unattended when it is being used! The appliance should be checked once a year by a qualified technician. Switch the appliance
off in the case of a failure or malfunction.
The appliance should be installed under an extractor hood for removing any cooking fumes.
Care must be taken when using the appliance because the cooking surfaces are very hot. The appliance must be
installed, connected and serviced properly by qualified personnel according to the regulations and directives in force in
the country where it is installed, as well as the instructions in this manual.
UNIT CHARACTERISTICS
These installation and user's instructions refer to the category II2H3+ gas ranges. The data plate is outside the back panel to
the appliance. The supplementary plate is also made of self-adhesive polyester and is affixed near the data plate; it contains all
information regarding the appliance. The gas distribution network fitting fig.1 meets ISO 7/1 and ISO 228/1 standards with a ø
½” connection, situated at the back of the machine. The structure of the appliance is made of stainless steel, the burners are
made of cast iron and the oven is made of stainless steel. All models have adjustable feet. The main gas pipe is made of
galvanized steel. The pipes between the tap and burner are made of copper.
Install a shut-off cock in the line between the appliance and the gas distribution network. Install an omnipolar switch
between the appliance and the electrical distribution network.
CONNECTION TO THE GAS DISTRIBUTION NETWORK
Before you install the appliance, make sure that the gas company has authorised the installation, compare the
data relevant of the appliance (data plate) with the local supply.
Remove the packaging from the appliance as well as the protective plastic sheet, and, if necessary, remove traces of glue with
a suitable solvent. To dispose of the packaging, follow local directives (for more details refer to the chapter “ECOLOGY AND
THE ENVIRONMENT”. Prior to connecting the unit to the gas network, check the data plate to see if the unit has been set and
tested for the type of gas supplied. If the gas type indicated on the data plate is not the same as that supplied, please refer to
the paragraph CONVERSION AND ADAPTATION”. Connect the appliance to the gas distribution network using metal pipes
with a suitable diameter; install a homologated shut-off cock between the appliance and the distribution network. If flexible pipes
are used, they must be made of stainless steel according to the standards in force. When installing the appliance, all the
regulations in force must be observed, such as:
Installation and safety standards in force.
Regional and/or local regulations, such as building codes.
Directives and regulations of the electricity board.
Accident prevention regulations in force.
Fire prevention regulations.
Applicable I.E.C. regulations.
We recommend installing the appliance in a well-ventilated environment, or under an extraction hood to remove the fumes or
vapors produced during the cooking cycle. All models have an equipotential earth terminal fig.1 in the bottom. The appliances
with an electric oven have a hole for the cable fig.1. The appliance can be installed alone or in line. Respect a minimum
distance of 80mm between the appliance and any walls made of flammable material, partitions, kitchen furniture or nearby
equipment. The contact surfaces must be covered with non-combustible heat insulating material. The appliance, and especially
the power lead, must not be installed anywhere near heat sources and the temperature of the place in which the appliance is
installed must not rise above 50°C. After installing the appliance check for any leaks in the fittings. Use non-corrosive foam
products, such as leak detection sprays, to look for any leaks.
When checking for leaks do not use naked flames!
The manufacturer shall not be held responsible and the guarantee is void in the case of damage caused by negligence
in following the operating and installation instructions or by improper use. The guarantee is void in the case of
connections which have been made in a way which doesn't meet the current standards and fire-fighting regulations.
EVACUATION OF BURNT GASES: A1 APPLIANCE
Appliances must be installed under an extraction hood with forced draught, subjected to gas supply.
7

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Hendi 226094 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Hendi 226094 in de taal/talen: Duits, Engels, Frans, Italiaans, Spaans als bijlage per email.

De handleiding is 4,66 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info