Only use spare parts supplied by Hayward brands®
Page 15 on 16AquaRite® Pro Touch
EN
6. SERVICING
During the rst 10-15 days, your system will require more attention:
- Check that the pH remains at the ideal level (7.2 to 7.4).
- If the pH is exceptionally unstable and uses a lot of acid, check the alkalinity (see table).
If the balance is highly unstable, contact your pool installer/builder.
REMEMBER that the system needs a certain amount of time to adapt to your pool and will require additional chemicals
during the rst 3-5 days.
The pool must be regularly maintained and the skimmer baskets emptied whenever necessary.
Also check that your lter is not clogged.
ADD WATER: It is preferable to add water via the skimmers so that it passes through the cell before entering the pool.
Remember to check the salt percentage after adding water.
DOSING PUMPS: Regularly check the acid level to ensure that the pump does not run dry. The dosing pump must be checked
and serviced at regular intervals. The Santoprene tube of the peristaltic pump has a lifetime of 2 years. We recommend that
you change it once a year.
Servicing the probe
The probe must be clean and free from oil, chemical deposits and contamination to function properly. As it is in continuous
contact with the water in the pool, the probe may need to be cleaned weekly or monthly, depending on the number of bathers
and other specic pool characteristics. A slow response, more frequent pH calibration and inconsistent readings indicate that
the probe needs to be cleaned.
To clean the probe, turn off the power to the AquaRite® Pro Touch.
Unplug the probe connector from the control box, unscrew the probe and carefully remove it from the chamber. Clean the
probe bulb with a soft toothbrush and regular toothpaste.
A household washing-up liquid detergent may also be used to remove any oil.
Rinse with fresh water, replace the Teon tape on the threads, and reinstall the probe.
If the probe continues to give inconsistent readings or requires excessive calibration after it has been cleaned, it should be
replaced.The lifetime of the probes is 1 year. We recommend that you calibrate them every month during the season the
pool is in use.
Servicing and cleaning the AquaRite® Pro Touch cell
Turn off the main power supply to the AquaRite® Pro Touch before removing the cell. Once it has been removed, examine the
inside of the cell for any traces of scale (whitish brittle or aky deposits) and debris stuck to the plates. If no deposits are visible,
reinstall the cell. If deposits are visible, try to remove them with a garden hose. If this method is unsuccessful, use a plastic or
wooden tool to remove deposits stuck to plates (do not use a metal tool as this will damage their coating). A build-up of deposits
on the cell indicates an exceptionally high concentration of calcium in the pool water. If you cannot nd a solution to this situation,
you will have to clean the cell at regular intervals. The best way to avoid this problem is to maintain the chemical composition of
the water at the recommended concentrations.
Acid washing: This should only be done in severe cases where ushing will not remove most of the deposits. To acid wash, turn
off the main power supply to the AquaRite® Pro Touch. Remove the cell from the piping. In a clean plastic container, make up
a solution of water and acetic or phosphoric acid (such as that used to remove scale from a coffee machine). ALWAYS ADD
ACID TO WATER – NEVER ADD WATER TO ACID. Be sure to wear rubber gloves and protective goggles for this operation.
The level of the solution in the container should just reach the top of the cell, so that the wire harness compartment IS NOT
under water. It may be helpful to coil up the wire before submerging the cell. Allow the cell to soak for a few minutes, then rinse
it with a garden hose. If the deposits are still visible, soak and rinse again. Put the cell back and examine it from time to time.
The lifetime of the cell is 3 years under ideal conditions. See the chapter on chemical water balance.
Wintering
The AquaRite® Pro Touch cell, the ow switch, probe and pool piping run the risk of being damaged if the water freezes. In
regions that experience long periods of cold weather, be sure to drain all the water from the pump and lter and from the
supply and return pipes before winter. Do not remove the control box.
Probe storage
The end of the probe must always be in contact with water or a solution of KCl. If it is removed from the measuring chamber,
it should be stored in the plastic cap provided (lled with water). If the storage cap has been mislaid, the probe should be
stored separately in a small glass or plastic container with its end immersed in water.
The probe must always be in a frost-free environment.
33

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Hayward AquaRite Pro Touch Salt Chlorinator bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Hayward AquaRite Pro Touch Salt Chlorinator in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Portugees, Spaans als bijlage per email.

De handleiding is 6.52 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info