AIR CONDITIONER SAFETY
We have provided many important safety messages in this manual and on your appliance. Always read and obey all
safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will
follow the safety alert symbol and either the word “DANGER,” “WARNING” or “CAUTION.”
These words mean:
An imminently hazardous situation. You could be killed or seriously injured if you don’t
immediately follow instructions.
A potentially hazardous situation which, if not avoided, could result in death or serious
bodily injury.
A potentially hazardous situation which, if not avoided, may result in moderate or minor
injury.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what
can happen if the instructions are not followed.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: To reduce the risk of fire electrical shock, injury to persons, or damage when using the air conditioner,
follow basic precautions, including the following:
Read all of the instructions before using this appliance.
Plug into a grounded outlet .
Do not remove ground
p .
Do not use an adapter.
Do not use an extension cord.
Do not operate the air conditioner if it has a damaged
cord or plug, if it is not working properly, or if it has
been damaged or dropped.
The air conditioner should be serviced only by
qualied service personnel. Call an authorized service
company for examination, repair, or adjustment.
Disconnect power before cleaning.
NOTE: Turning power by pressing the Power button
does NOT disconnect the appliance from the power
supply.
Do not install or use the air conditioner in any area where
the atmosphere contains combustible gases or where the
atmosphere is contaminated. Avoid any chemicals coming
in contact with your air conditioner.
Do not store anything directly on top of the air conditioner.
Use two or more people to move and install air conditioner.
Never operate the air conditioner without the filter in
place.
Do not use the air conditioner near a bathtub, shower or
wash basin or other wet area.
READ AND SAVE THESE INSTRUCTIONS
2
ENGLISH
Your safety and the safety of others are very important.
DANGER
WARNING
CAUTION
AND FEATURES
ON REQUIREMENTS
TOOLS AND PARTS
Gather the required tools and parts befiore starting
installation.
3
4
1
2
3
5
Hi
g
h
Co
o
l
Fa
n
D
r
y
M
i
d
Lo
w
7
9
8
6
Han dle
1
Air inlet
2
Con trol pan el
3
Wind guide bar
4
Cast er
5
Air inlet
6
Air outlet
7
Deh umidifica tion drainag e nozzle
8
Air inlet grille
9
PARTS SUPPLIED
TOOLS NEEDED
Main Window Panel
Flat-blade Screwdriver
Extension Panel
Remote Control for
Cooling Only Model
Remote Control for
Cooling&Heating
Model
Screw (2)
1
for extension panels
1
for nozzle
LOCATION REQUIREMENTS
Place the air conditioner on a flat level surface in a
location that is at least 51 cm from any wall.
NOTE: A minimum clearance of 51 cm from the air
conditioner to the wall must be maintained to ensure
proper airflow
Maintain a minimum 51 cm clearance around the air
conditioner to not block airflow
Keep the air conditioner free of any obstructions such as
drapes, curtains, blinds, etc.
The exhaust hose should be free of any obstructions.
Do not place the air conditioner on an unstable or raised
surface because it could fall and cause damage or injury.
Do not place the air conditioner in direct sunlight or near
a heat source such as baseboard heaters, stoves, etc.
The window panel can be installed in a window with a
90 cm to a maximum 130cm opening.
ELECTRICAL REQUIREMENTS
POWER SUPPLY CORD
Wiring Requirements
230 Volt, 50Hz, 16-amp fused grounded outlet
The use of a time-delay fuse or time-delay circuit breaker
is recommended.
Use a dedicated circuit only.
NOTE: Do not operate any other electrical
appliances on this circuit or you may trip the circuit
breaker/fuse.
If this power supply cord is damaged, it cannot be repaired. It
must be replaced with a cord from the product manufacturer.
4
ENGLISH
WARNING
Electrical Shock Hazard
Plug into a grounded outlet only.
Do not remove the ground contacts from the power
cord plug.
Do not use an adapter.
Do not use an extension cord.
o follow these instructions can result in death,
fire shock.
Hi
gh
Co
o
l
F
an
D
r
y
A
u
t
o
M
i
d
L
o
w
H
i
g
h
C
ool
F
an
D
r
y
Au
t
o
M
i
d
L
o
w
Exhaust pipe assembly
11
6
ENGLISH
B
A
Exhaust pipe assembly
Window panel
STEP 4 - CONNECT EXHAUST HOSE
TO THE AIR CONDITIONER
IMPORTANT: When connecting the hose, the air
conditioner must be close enough to the window that
you will not dislodge the window seal plate. Once the
hose is connected, move the air conditioner 51 cm from the
wall.
1. Align the notches on the connector end of the exhaust
hose with the ridges in the opening on the back of the
air conditioner.
2. Using a counterclockwise motion, screw the exhaust
hose (connector end) into the air outlet located on the
back of the air conditioner.
A
B
STEP 5 - COMPLETE INSTALLATION
Plug into a grounded outlet only.
Do not remove the ground contacts from the
power cord plug.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire or electrical shock.
WARNING
Electrical Shock Hazard
7
ENGLISH
TIMER BUTTON
FAN SPEED BUTTON
REMOTE CONTROL SIGNAL RECEIVING WINDOW
CONTROL PANEL DISPLAY
UP AND DOWN ARROW BUTTONS
MODE BUTTON
POWER BUTTON
SWING BUTTON
Press this key at any time after turning on the A/C to
swing the wind guide bar automatically.
H
E
6
three
1
TROUBLESHOOTING
First try the solutions suggested here to possibly avoid the cost of a service call.
TROUBLE CAUSE SOLUTION
The A/C doesn’t work Not plug in
Plug in
The display panel displaysFL Restart the A/C after power off anddraining, then it
will become normal
Time OFF function is started
The A/C can be restarted 3 minutes after being
turning off.
Direct sunlight Draw the curtain
Doors and windows keep open; there are lots
of people or heat source in room
Close doors and windows, remove heat source
Filter screen is very dirty
Air inlet or air outlet is blocked
Clean or replace it
Remove the stem
The A/C is placed unevenly
Place it at even and firm ground,avoid shaking
Wait for 3min., turn on it after temperature
decreases
Its delay protection is started
ENGLISH
The A/C starts
frequently
Big noise of the
A/C
The compressor
doesn’t work
13

Hulp nodig? Stel uw vraag in het forum

Spelregels
1

Forum

Haier-AM12AA1GAA
6

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Haier AM12AA1GAA bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Haier AM12AA1GAA in de taal/talen: Engels als bijlage per email.

De handleiding is 4,53 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Andere handleiding(en) van Haier AM12AA1GAA

Haier AM12AA1GAA Gebruiksaanwijzing - Nederlands - 17 pagina's

Haier AM12AA1GAA Gebruiksaanwijzing - Français - 18 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info