General instructions for operation,
installation and maintenance
COMBINED FIREPLACE STOVE WITH
WARM WATER EXCHANGER
HAAS + SOHN Rukov s.r.o.
MANUFACTURER:
SNP 474, 408 01 RUMBURK, CZECH REPUBLIC
COMPANY ID: 62740989 TAX ID: CZ62740989
CONTENTS
1. TECHNICAL SPECIFICATIONS ........................................................................5
1. 1. Heating concept ................................................................................................. 5
1. 2. Construction design ........................................................................................... 5
2. BURNING PROCESS........................................................................................ 6
2. 1. Fuel quantity and firing process adjustments ..................................................... 6
2. 2. Fuel.................................................................................................................... 7
3. SAFE OPERATION ........................................................................................... 8
3. 1. General requirements ........................................................................................ 8
3. 2. Safe distance between the fireplace stove and flammable material................... 8
3. 3. Safe distance between the smoke flue and flammable material......................... 8
3. 4. Directions for safe operation .............................................................................. 8
4. INSTALLATION AND CONNECTION TO THE CHIMNEY ................................9
4. 1. Connection to the chimney or chimney insert..................................................... 9
4. 2. Connection to the chimney vent......................................................................... 9
4. 3. Directions for smoke flue installation and safety ................................................ 9
4. 4. Installation of the fireplace stove within the room .............................................10
4. 5. Connection of the fireplace stove with an exchanger to the heating system......10
4. 6. Installation instructions and use of pressure expansion tanks............................11
4. 7. Cleaning the heating device and chimney..........................................................12
4. 8. Chimney fire.......................................................................................................12
4. 9. External combustion air supply system..............................................................
12
5. OPERATING INSTRUCTIONS..........................................................................12
5. 1. Before first operation..........................................................................................12
5. 2. Setting the fire....................................................................................................13
5. 3. Feeding the fire ..................................................................................................13
5. 4. Glass cleanness.................................................................................................13
5. 5. Operation during temporary period and at worsened weather conditions ..........13
5.6. How to substitute the blind element by the exchanger.......................................14
5. 7. Ash removal .......................................................................................................14
6. CLEANING AND MAINTENANCE ....................................................................14
6. 1. Cleaning.............................................................................................................14
6. 2. Cleaning the ceramics and tiles .........................................................................15
6. 3. Cleaning the warm water exchanger..................................................................15
6. 4. Sealing lines and tapes......................................................................................15
6. 5. Spare parts.........................................................................................................15
7. WHAT TO DO IF… DO YOU DO IT YOURSELF?............................................15-16
8. FREQUENT PROBLEMS AND QUESTIONS ..................................................17
8. 1. Cracked (released) fireclay (vermiculite) brick in the burning area.....................17
8. 2. Broken glass ......................................................................................................17
8. 3. Partitions to control the chimney effect ..............................................................17
8. 4. Cracked side tile.................................................................................................17
8. 5. Replaceable exchanger (option) ........................................................................18
9. PRODUCT LIABILITY AND SERVICE..............................................................18
9. 1. General ..............................................................................................................18
9. 2. Conditions for guarantee....................................................................................18
9. 3. Guarantee and post-guarantee service..............................................................18
9. 4. Claim rejected ....................................................................................................18
9. 5. How to make a claim..........................................................................................19
9. 6. How to order spare parts....................................................................................19
10. MISCELLANEOUS............................................................................................19
JK 04 164 27 41 14 00 h
10. 1. Accessories supplied with the fireplace stove ....................................................19
10. 2. Special accessories (on order)...........................................................................19
10. 3. Recommended spare parts................................................................................19
10. 4. Package and waste disposal..............................................................................20
10. 5. ES Declaration of Conformity and CE Certificate...............................................20
10. 6. HAAS+SOHN Rukov s.r.o Products and Manufacturing Programme................20
10. 7. Caution!.............................................................................................................21
11. SUPPLEMENTS ...............................................................................................21-25
Congratulations! You have just bought the fireplace stove HAAS + SOHN, a top-quality
product. Thank you very much for your interest and purchase. Kindly read the Operating
Instructions to find out comprehensive information about the function, correct use and
handling. We recommend you to read the instructions carefully in order to avoid any risk
related to likely damage. Proper operation and maintenance affects the service life of the
product as well. In addition, proper operation and fuel supply is connected with fuel savings
and environment protection. Technical specifications are included in the manual.
The manufacturer provides guarantee providing you adhere to the directions and
recommendations in the instructions for operation and maintenance. Keep the operating
instructions and technical card safe to be able to refresh your knowledge at the beginning
of the new heating season.
1. TECHNICAL SPECIFICATIONS
The combined fireplace stove with the warm water exchanger is designed for heating in
habitable rooms, recreational buildings, work stations and other places to provide thermal
comfort, while the visual effect the perception connected with flame is similar to the
sensation of live fire. The warm water distribution system may be open or closed, made
with an auxiliary circulating pump or without the pump. The warm water distribution system
may be completed with e.g. service water heater. A good solution may be an integration of
the fireplace stove to the already built heating system with a gas boiler (electric boiler, or
other heating systems). In order to provide safety operation of the fireplace stove and
automatic back-up for the function of the circulating pump in case of electric power failure, it
is recommended to use a back-up power supply (See Supplement 3).
1.1. Heating concept
The fireplace stove is designed for burning wood, eco-fuel cakes and coal cakes (specific
types only) in a burning-through way, characteristic with very good firing conditions.
By means of the warm water exchanger, the fireplace stove hands some 50% of the heat
output in the central heating circuit or floor heating. The rest of the available heat is used
for heating of the air in the room where the fireplace stove is installed.
The air within the room is heated thus the thermal comfort is provided by heat convection,
in part by heat radiation as well. This way, you can heat up even very cold, long-time
unheated rooms very quickly. The concept of heating by means of heat convection is based
on the fact that the air in the room enters the fireplace stove at its bottom part, being heated
in the course of its way up inside the convection space consisting of a double shell of the
heating device. The air then flows through the holes in the upper part of the fireplace stove
back in the room. The radiation heat is generated by means of surface areas of the
fireplace stove (metal, ceramics, glass). Due to the construction, the biggest radiation heat
source is the glass door.
1.2. Construction design
The fireplace stove is welded of steel profiles, thickness 2-5 mm. In the middle of the
fireplace stove, there is a firing chamber that may be closed with a stocking door (equipped
with a self-acting element). The door is provided with special a large-area glass sheet,
thermal resistance up to 800 °C.
The inner space of the firing chamber is usually lined with fireclay brick shapes. The bricks
are not jointed with any filler (the reason is a protection of the bricks against damage by
thermic dilatation). The upper part of the firing chamber is equipped with partitions
designed for directing flue gases into a smoke outlet. The partitions may be fixed or
movable. Such movable partition may serve as a supporting holder for fireclay bricks. At
the bottom part of the firing chamber, a simple, fixed cast grate is installed. Before the
4 5
grate, a barrier is usually provided, to prevent from burning pieces falling out or onto the
door (front glass). Under the grate, there is a space designed for ashpan. The remaining
space at the bottom part of the fireplace stove may be used for spare fuel.
Fireplace stove casing is made of steel panels, ceramic tiles or lined of thick tiles. The
fireplace stove steel construction is protected with special refractory paint.
A part of the fireplace stove system is a warm water exchanger. It is welded of steel pipes,
thickness 4 - 5 mm. The exchanger may be an integrated part of the fireplace stove or may
be removable. Such removable exchanger is screwed to the fireplace stove. If you need to
remove it, you blind the connecting point. This way, you modify the fireplace stove into a
purely air heating system.
The outlets of the heating water are situated on the rear side of the exchanger. The hot
water outlet is marked in red. The reverse (cooler) water is marked in blue.
Caution! The fireplace stove is not designed for continuous heating but for
periodical – interrupted (i.e. temporary) operation.
2. BURNING PROCESS
2.1. Fuel quantity and firing process adjustments
Burning wood, wood cakes (or coal cakes optional) in the fireplace stove is based on
burning through the fuel, which means that such firing takes place throughout the whole go
of the fuel at a time. In order to provide optimal conditions for easy kindling and burning up,
you need enough air being led under the fuel in fire, through the grate: this is the so-called
primary air, and it must be always controllable. By increasing temperature of the fuel
burning through, certain gaseous components of the fuel evolve that unless additional air
is supplied would be of no avail in terms of heat energy: therefore, additional air must be
provided at the flame level where the firing process connected with those gaseous
components may continue. Now, at this stage, the primary air is in fact not necessary,
while secondary air supply is required, or tertiary air may be added as well, respectively.
The secondary air supply, usually adjustable, improves the firing process and contributes to
the door glass self- cleaning. The tertiary air supply is designed for general improvement
of the firing process and is usually fixed (one cannot regulate it anyhow). If the proportion of
the air volumes led into the particular sections of the firing chamber is correct, the burning
efficiency is increased while emission of pollutants in the environment is reduced. The
layout of the air supply regulative elements is shown in the Technical Cart (a part of the
documentation supplied with the fireplace stove).
Our models of fireplace stove may reach up to 85% efficiency which means top
performance.
The heating capacity of the heating device depends on the fuel quantity burnt per defined
time, fuel quality and firing process efficiency. Using the Chart 2 (heating values) may help
you to make a picture of attainable capacity: let’s assume that you burn 1 kg of wood per
hour, wood humidity is 20%. Further, with higher wood moisture its heating capacity goes
down.
In the testing room conditions, adjustability of the heating device was tested, within 30
100% of nominal performance. For the regulation, the chimney effect and the fuel quantity
were applied. In practice, the heating capacity may be regulated by means of air supply
regulating elements (especially the primary air inlet). There is no simple and explicit way to
determine the firing process adjustment by means of regulators. There are many aspects to
consider fuel moisture, type of fuel, chimney effect, exterior pressure conditions, etc.
Therefore, the firing process (the flame intensity and quality) should be re-adjusted for
particular conditions.
You will be able to adjust the firing process to achieve best efficiency after a short time of
operation. A detailed chart showing how to adjust the air supply regulating elements is
included in the technical specifications. The figures in the chart are the testing results
verified by the State Testing Laboratory. The Chart 1 presents just general information for
air supply adjustment.
Primary air Secondary air Tertiary air
Fuel Fuel quantity
Adjustable Adjustable No adjustment
wooden
logs
wood
cakes
2 - 3 logs (approx. 2 – 3
kg)
2 - 4 logs (approx. 2 – 3
kg)
Open wide
Fixed adjustment
at installation
coal cakes
2 - 3 logs (approx. 2 – 3
kg)
Closed or open
(depends on local
conditions)
half-open
Fixed adjustment
at installation
Chart 1
Our tips for wood burning
Any time you set the fire, let the primary air regulator open long enough to allow the fuel
burning properly.
Before you re-load, it is recommended to open the primary air regulator wide.
While burning wood, make sure the wood is dry, maximum moisture 20%.
In order to use the optimal exchanger performance, it is recommended to load and
maintain the wood during the operation just on the grate.
Our tips for coal cake burning (selected models only)
To achieve optimisation of the firing process, load the cakes directly onto the grate holes:
this way, you support the burning in best possible way.
Make sure you do not overload: for the heat capacity you may use, i.e. to maintain the heat,
a couple of cakes is enough: otherwise the device would suffer from excessive heat. Coal
cake fuel efficiency may reach 6 kWh/1 kg, i.e. by some 40% more than wood!
2.2. Fuel
In fireplace stoves, you may burn logs, wood cakes and coal cakes (some models only).
The moisture of the wood to be burnt should be lower than 20%, optimally 10%. The rule of
thumb is: the less water in the fuel, the higher heating capacity you achieve. For the
recommended wood moisture, you may reach it safely if you store the wood in a well
ventilated shelter for at least two years. The water content in coal cakes should be
specified by the manufacturer. The cakes should be stored in a dry room otherwise they
disintegrate. It is recommended to store the wood intended for burning in pieces approx. 3-
6 cm (diameter), 20–30 cm (length). It is forbidden to load and burn coal or charred
coal. In the fireplace, never burn flammable liquids or waste. It is forbidden to burn
papering, chipboards, plastic materials, penetrated wood, wood shavings or saw dust.
Burning such materials not only is detrimental to the environment but shortens the service
life of the heating device as well: you might seriously damage the device or the chimney as
well.
Note: The bark, a part of wooden logs, is no issue at all.
Fuel efficiency: selected types of wood at moisture 20%
Wood Fuel efficiency
kWh/m3
Fuel efficiency kWh/1
kg
Weight kg/(m3)
Spruce, fir 1957 4,0 485
Larch 2461 4,0 610
Pine 2280 4,0 565
Oak, beech 2743 3,8 726
Chart 2
6 7
3. SAFE OPERATION
3.1. General requirements
While installing and operating stove, it is obligatory to adhere to the fire prevention
regulations (related to this type of devices) in force in the country of installation.
The device is designed for standard environment. In case of any temporary change
establishing any temporary danger of fire or explosion (for example, while installing
linoleum flooring, PVC, painting, etc.) it is crucial to put the heating device out of operation
IN TIME, BEFORE ANY POTENTIAL DANGEROUS SITUATION MAY OCCUR. At the
end of the work, do not start using the fireplace stove again until the room conditions are
brought back to normal (it is recommended to provide fresh air by draught).
3.2. Safe distance between the fireplace stove and flammable material
If you have installed the fireplace stove within the room with flammable objects,
flammability Class B, C1 and C2, the safety distance from the front (or side glass surfaces)
is 800 mm; for the other directions, the safety distance is 200 mm. If the fireplace stove is
installed within a room with flammable objects, flammability class C3, the safety distances
must be doubled. Kindly pay attention to the information provided in Supplement 1. The
most important installation dimensions are shown in the product name plate.
3.3. Safe distance between the smoke flue and flammable material
The safety distance from the door frame lining and similar constructions made of flammable
materials and from pipeline installations, incl. insulating elements is 200 mm (minimum).
The safety distance from the other parts of the constructions made of flammable materials
is minimum 400 mm. This is applied to building materials, flammable Class B, C1 and C2
(see Chart 3). Kindly pay attention to the information provided in Supplement 2. More
accurate classification is available only if testing is performed for the particular product.
3.4. Directions for safe operation
For firing or kindling, never use any flammable liquid! It is forbidden to burn any plastic
material, wooden material combined with chemicals (chipboard, etc.) or domestic
(unsorted) refuse containing plastic, etc.
The fireplace stove must be operated by adults only! Never allow children in the
room unattended. The surface of the fireplace stove is overheated, especially the
glassy components: any contact will cause serious burnt. During the operation,
occasional monitoring is required. For safe operation and handling the regulation elements
and the door closing devices, use the protective glove (a part of the supply). Do not put any
objects or tools on the fireplace stove while in operation or hot: flammable material may
cause fire. Do not put any vessels with cold liquid in the ceramic –tiled fireplace stove while
hot: the tiles may crack!
The ashpan must be manipulated with utmost care. The ash may be very hot so there is
danger of serious burnt. Hot ash must not be in contact with flammable material for
example, while pouring it into waste container.
The fireplace stove must be operated in compliance with the directions and
recommendations in the Operating Instructions. It is forbidden to modify the
fireplace stove in any way unless approved by the manufacturer.
Flammability class: selected building materials
Building materials and products
Building materials
A – Flame proof matter Granite, sandstone, heavy concrete (porous), brick, ceramic tiles, special
plaster
B - heavy fuels Akumin, Heraklit, Lignos, Itaver
C1 – hardly inflammable Hardwoods, Hobrex panels, Sirkolit, hardened paper, umakart
C2 – medium inflammable Chip boards, Solodur, cork parquet, rubber, floor covering
C3 - Flash fuels Wood-fibre boards, polystyrene, polyurethane
Chart 3
4. INSTALLATION AND CONNECTION TO THE CHIMNEY
Caution! For installation, relevant local regulations must be strictly adhered,
including the regulations related to national and European standards for this type of
device.
4.1. Connection to the chimney or chimney insert
Connection of the fireplace stove to the chimney vent is subjected to approval by specialist
chimney company (CSN 73 4201:2008), or to approval according to relevant regulations in
force in the country where the installation is made. Kindly pay attention to the information
provided in Supplement 2.
To provide proper function and operation, proper chimney effect in the smoke flue
neck is required. For the minimum stack draught, see the Technical Card for the particular
product. Insufficient chimney effect results in malfunction of the fireplace stove, excessive
dirt on the glass, and excessive clogging in the smoke flue system. The general heat
capacity of the device is reduced. If you feed the fire while proper chimney draught is not
provided, flue gases may spread throughout the room. For this reason, it is strictly
recommended to have regular check done by a specialist chimney company and maintain
the heating device regularly. If the chimney effect is too high (over 20 Pa it is recommended
to install a suitable blocking device for example, flue tube with a block). Excessive chimney
draught may cause troublesome operation, for example, too intensive burning, high fuel
consumption, damage on the heating device, etc.
4.2. Connection to the chimney vent
It is recommended to connect the stove to a separate chimney vent. A joint chimney vent
may be used for the connection only if the safety regulations valid in the country of
installation allow doing so. It is forbidden to connect the stove to the same vent used for a
gas appliance. The minimum working height of the vent is 5 m. Depending on local
conditions, it is possible to connect the stove in the vent with a working height under 5 m
providing that the flue way calculation demonstrates that such a height is satisfactory.
Caution! (Provisions CSN 73 42 01: 2008)
The smoke flue vent diameter must not exceed the diameter of the chimney vent; it must
not be narrowed towards the chimney, either. If the calculation demonstrates that the vent
diameter of the smoke flue and chimney can be smaller than the flue neck diameter of the
device, the diameter of the smoke flue will be reduced just after the flue neck of the device,
by means of a short transition or abrupt.
4.3. Directions for smoke flue installation and safety
Connect the smoke outlet neck with the chimney in the shortest possible way so that the
length of the smoke path is no longer than 1.5 m. The smoke pipes and the elbow piece
must be tightly connected, overlapping at least 60 mm. Pay special attention to the fact that
the joints must agree with the flue outflow. The joint between the smoke flue and the smoke
outlet neck must be drilled together and fixed with a rivet or pin; the same is applied for the
9
8 9
smoke pipes and the elbow. The hole (entrance point) in the chimney must be provided
with a metal stress ring (proper diameter). The smoke flue should ascent towards the
smoke uptake at angle approx. 10°.
4.4. Installation of the fireplace stove within the room
Before any installation work is started, you need to verify the floor (ceiling) load capacity.
The load conditions for the particular type of the device must be met (depending on the
particular weight). The fireplace stove must be installed on a heat insulating base that
overlaps the fireplace stove ground plan dimensions on the sides and in the rear by at least
100 mm; the overlap in the front (the direction of the feeding opening) is 300 mm. If a metal
base is used, the thickness must be at least 2 mm. Kindly pay attention to the information
provided in Supplement 1.
Caution! Make sure you provide space enough for easy approach to the device, smoke
flue and chimney for the purpose of cleaning.
4.5. Connection of the fireplace stove with an exchanger to the
heating system
Caution! Order the design and the installation of the warm water distribution system or
service water supply at a specialist company!
For any installation of warm water pipeline, the requirements on heat systems and
networks in buildings valid in the country of installation must be adhered to.
Related regulations:
Heat systems in buildings – Safety devices
Heat systems in buildings – Design and installation
Heat systems in buildings – Hot water production
Heat systems in buildings – Designing hot water heat systems
Heaters using fossil fuel designed for dwelling space
Built-in heat devices and stove inserts using solid fuel
Caution! According to Article 3 par. 2.3 EU Directive No. 97/23/ES “Pressure devices” the
necessity to provide the fireplace stove and fireplace inserts with an exchanger (solid fuel
loaded manually, used for preparation of warm water up to 110°C) with an overheat
safety element is subjected to approval. It means that if your fireplace stove with an
exchanger or the fireplace insert with an exchanger is not equipped with such a
safety element, it is not obligatory for the particular model!
The exchanger must be connected in the warm water distribution system with a threaded
element. For this purpose, the exchanger is provided with threaded outlets. Consult the
connection of the exchanger in the system with the specialist company that will install the
heat system in your house. The connection should be made by means of pressure flexible
armoured hoses to allow an option of disconnection or replacement when needed. This
way, the assembly (disassembly) of the exchanger is easier, and it is possible to put the
fireplace stove out of operation, providing access to the chimney, smoke flue elements
disassembly for cleaning, while an easy approach in the upper part of the burning area is
provided as well.
In case that you plan to use the fireplace stove for occasional heating of the room in which
the fireplace stove is installed (only), you need to “redirect” the capacity of the exchanger to
avoid heat overload: you need to redirect the capacity to another heat consuming appliance
(e.g. a water tank). You can also install such appliances in the room where the fireplace
stove is. If you do so, the operator may “redirect” the heat output by closing the valves of
the particular appliances or the whole branch supplying the heat to direct the heat intended
for other rooms just in those selected.
The connection with the accumulation is recommended only if you can guarantee the
consumption of at least 50 % of the nominal output by other appliances. (For example, you
can form a combination of accumulation tank and a heating body).
Such forced heating system may be protected against overheat by e.g. use of an open
expansion tank, by installation of a supplementary cooling circuit or a cooling exchanger
(loop). In case of electric power failure, the best solution is to use a back-up source for
circulating pump.
It is recommended to install thermostatic heads on the heating bodies (especially in the
room where the fireplace stove is installed).
Caution! The cooling exchanger (loop) is designed in such a way that full protection
against the exchanger heat overload is provided. To guarantee correct function and
working connection, you need to arrange for cold water input under constant pressure 2 bar
and temperature up to 15°C, i.e. the water source mus t be independent on electric power
failure (the best solution is the water mains). The cooling water is led from the cooling
exchanger in the sump.
Caution! To increase the service life of the exchanger and improve the initial phase of
heating with the forced systems, it is recommended to equip the pump with a switching
thermostat or thermoregulation valve.
Caution! The lowest part of the heating system MUST be provided with a recharge valve.
Caution! The fireplace stove equipped with an exchanger cannot be used without the
connection of the warm water distribution system and filling with heat-carrying medium,
i.e. water or frost-resistant fill recommended for this purpose.
4.6. Installation instructions and use of pressure expansion tanks
Order the installation of the expansion tank at a specialist company. Providing opportunity
to check the system from any side. The tank label must be well-visited. The tank must not
be installed in freezing conditions.
Pressure expansion tanks are classified the “special technical devices”, thus
subjected to the following:
An initial inspection in case of a newly installed tank, before putting into operation
A regular operation inspection once a year. Within the operation inspection, the gas
pressure is measured.
An inside inspection – once per 5 years.
A pressure test – once per 9 years.
Caution! The pressure of the gas in the expansion tank must not drop under 1 bar!
Caution! Always order the inspections at a specialist company.
Maintenance work must be carried out by an authorised service centre – once a year:
A visual inspection of the tank for damage and corrosion (replacement or proper action
as required)
Short release of the nitrogen valve (if water starts leaking, replace the tank or the
membrane)
Check the gas filling – the tank must be empty
Check the water filling within the system – the water temperature must be the same as
the ambient temperature
The specifications are informative only and must be adjusted to the regulations in force
in the country of installation.
10 11
4.7. Cleaning the heating device and chimney
In the course of the installation of the fireplace stove and connection to the chimney vent,
approach in the chimney for occasional cleaning of chimney pipes and the chimney as well
is required. By regular cleaning of the smoke pipes and the firing space in the fireplace
stove, you may optimise the performance of the heating system. By regular chimney
cleaning, you avoid inflammation of fouling solid particles caught on the chimney walling.
4.8. Fire in the chimney
In case of fire in the chimney, put out the fire in the stove immediately: remove the burning
fuel remnants with a shovel (put them aside in a suitable non-flammable container) and call
the fire brigade immediately: Call the fire brigade or the integrated rescue system centre.
4.9. External combustion air supply system
For the firing process, enough fresh air supply is needed. While firing wood, the device
needs up to 15 m3 of fresh air per hour. In case of newly built houses, the insulating
materials used in the house result in low airiness coefficient for the house, due to plastic
windows, etc.). Another issue may be exhaust devices or other heat installations in
operation in the room or within the space where the fireplace is installed.
In such well-insulated houses, the quality of the firing process is lower, being accompanied
with tarring and smoke path clogging (and/or smoke penetration and spread in the room).
Make sure that the air supply in the room is sufficient, by open windows or door in the next,
better ventilated room. It is more convenient if you along with the installation of the
heating device install a ventilation hole to provide air supply, equipped with a regulating
grate (protected against clogging).
5. OPERATING INSTRUCTIONS
5.1. Before first operation
Before the first putting into operation, you have to remove labels from the glass,
accessories found in the ashpan or inside the hearth, including transport clamps etc.
Following the illustration in the Technical Card, check that the movable partitions designed
for directing the flue gases, fireclay brick shapes or the barrier are located properly (they
may have moved out of the position during the transportation or installation work). If you
find any wrong position, correct it; otherwise, the heating device might not work properly.
The fireplace stove surface layer is provided with fire-resistant paint being softened to
become harder after the first fire made in the fireplace stove. During the soft phase, pay
special attention to danger of damage on the surface by touching it with fingers, tools, etc.
For the very first use, the initial fire should be very small, to “warm up” the device gradually:
it is recommended to load smaller quantities to establish lower temperature. All materials
need the initial lower- temperature phase in order to “get used to” the thermal stress. By
such slow heating up, you avoid cracks in fireclay bricks, likely damage on surface paint or
material deformation in general.
The odour generated during the paint hardening process at the first putting into operation
is just temporary – however, it is recommended to ventilate the room intensively. If pets are
present, move them to another room for a while.
With the models equipped with the glass door comprising of three parts, check the
segments for gaps (which may be formed during the transport or the first use).
What to do if you find a gap between the glass segments: Partially release the holder
nuts. Move the glass segments (carefully!) closer to each other: the edges should touch
slightly. Slowly and carefully, tighten up the holder nuts.
5.2. Setting the fire
To set the fire easily, follow this procedure: Put 2 or 3 smaller wooden logs onto the bottom
or on the grate. Add paper or permitted fire lighters, then brushwood, small firewood and
thicker logs (the last layer). You should always load a bigger quantity (i.e. enough wood,
which means up to approx. 2/3 of the height of the fireclay (vermiculite) lining. By loading
such bigger quantity, you establish time long enough in order to heat the chimney thus set
the proper conditions for the chimney function. Open the primary air regulator wide
(maximum). Sometimes it is good to reduce the secondary air supply at this moment the
fuel catches the fire better. After setting the fire, keep the door shut all the time. As soon as
the wood flares up properly, use the air supply regulators to set not very intensive, rather
slow burning. To adjust the flame and the burning, you may apply the information specified
in the Technical Card or Chart 1.
You may poke the fire when needed, using the fire hook or the poking lever (if installed).
Caution! Before any new fire, check the water quantity (pressure). With forced
circulation systems, check the function of the circulating pump. Check the grate for
dirt (clogging), remove (rake) the excessive ash away from the grate.
Caution! The stoking door (the firing chamber) and the ashpan door (if installed with
your particular model) must be kept shut all the time, except setting the fire, fuel
reload or ash removal.
Caution! After every standby for a longer time, before you set the fire again, check
the fireplace stove for clearness and cleanness of the smoke flue, chimney and firing
area.
5.3. Feeding the fire
To prevent the smoke spreading throughout the room during the fire feeding, the following
is recommended: Approx. 5 to 10 seconds before you open the stoking door, open the
primary air regulator wide. Then, open the stoking door a bit only, wait for a couple of
seconds to allow the smoke exhausting through the chimney. After that, open the door
wide. Pay attention to the door any time you open it: do not allow live cinder fall out. When
you reloaded the wood, shut the stoking door. When the fuel burns up (no carbon black
flame), bring the regulating system back in the previous position (or close the regulator,
respectively). While feeding the fire, make sure the wood does not exceed the level of the
fireclay (vermiculite) lining in the firing area. The quantity of the fuel reloaded should be
more or less the same as specified in the information provided about the hourly
consumption for the particular model of the heating device (see the Technical Card). If you
overload the fireplace stove with excessive fuel, you may cause permanent damage to the
fireplace stove construction.
Caution! If you want to avoid unnecessary smoke spreading throughout the room
during the feeding, reload the wood after the previous load has burnt up to cinders.
5.4. Glass cleanness
The cleanness of the transparent glass depends on the type of the fuel, proper combustion
air supply (this is applied especially to the secondary air), the chimney effect and last but
not least on the way how the fireplace stove is operated. It is recommended to load one
layer of the wood only: the logs should be laid evenly, farther from the glass (as far as
possible). The rule is the same for coal cakes as well (keep the distance 5 to 0 mm
between them). If the glass is dirty, we recommend increasing the firing intensity by
opening the primary air regulator, which usually supports the self-acting cleaning process.
5.5. Operation during temporary period and at worsened weather conditions
For temporary periods , for example, during the time when outdoor temperature is above
15
o
C, during rainy and wet days, in case of gusty wind, etc. the chimney effect may worsen
12 13
thus the smoke is not led away in full as usual. Therefore, during such period, you should
operate the fireplace stove with smallest possible quantity of fuel, to allow improving the
firing process and the chimney effect by opening the air inlets in case you need to make
adjustments.
5.6. How to substitute the blind element by the exchanger
With selected models, the warm water exchanger is screwed in the construction of the
heating body. Therefore, when you remove the exchanger, you need to install the so-
called blind element. The blind element serves as a flue conditioner as well. The fireplace
stove modified in this way becomes an air heating device then. The blind element is
supplied as special accessory (detailed instructions for operation and installation provided).
Caution! A fireplace stove equipped with a warm water exchanger must not be
operated without the connection to the warm water distribution system or the water
filled in, or without anti-freezing mixture, respectively.
5.7. Ash removal
Depending on the length and the intensity of the firing process, you need to use a fire hook
or poking lever (if installed with the particular model) in order to knock the ash down the
grate to the ashpan. Monitor the content of the ashpan - do not allow too much ash in
it. Excessive ash may block the air supply under the grate thus causing problems at
fire setting or burning.
Always empty the ashpan when cold. The best approach is to empty the ashpan just before
you start preparing the next fire. Ash from wood may be used for composting or for
fertilizing.
Caution! Before you touch the ashpan to empty it, check it for fire brand. Prevent any
likely fire in the dustbin.
6. CLEANING AND MAINTENANCE
6.1. Cleaning
The fireplace stove (cold) needs cleaning at least once a year (after the season), or twice
or more (if needed). During the cleaning, you should remove any dirt caught in the smoke
flue, the firing area and on the partitions. Loose parts of the fireclay lining should be
repaired (i.e. replaced). Check the fireclay lining for integrity even during the heating
season. The gaps between the brick shapes are designed for heat dilatation, to avoid brick
cracking. Therefore YOU SHOULD NOT fill any sealing in the gaps (as it used be before
with older heating devices).
Cracked fireclay bricks do not lose the function unless they are completely fallen out
of the position!
In the course of the cleaning procedure, we recommend you to remove all movable
partitions (for easier access in the area above them). To clean the glass, apply standard
cleaning agents designed for cleaning fireplace stove, cooker or oven. Use a soft cloth or
paper, or special agents designed for cleaning fireplace glass, e.g. CINOL. Only clean the
glass when cold. For cleaning the painted surface, never use water: it is recommended to
clean such surface with sponge or soft flannel cloth.
Caution! With selected types of fireplace stove, the vertical side of the firing area is
provided with VERMICULITE. The same material is used for some chimney effect
conditioners. The material is irreparable. In case of any damage, just replace it.
Vermiculate products are characteristic with top heat-insulating parameters and good
resistance to cracking. The resistance to abrasion is somehow lower so it is recommended
to keep this in mind while reloading and cleaning.
6.2. Cleaning the ceramics and tiles
To clean ceramic tiles or tiles, it is recommended to use a dry or slightly wet cloth. Clean
the fireplace stove only while cold.
6.3. Cleaning the warm water exchanger
The exchanger vents require cleaning (when needed). Use the brush (a part of the supply).
Clean the exchanger vents at least once a heating season. The level of dirt depends
especially on the wood moisture and on the operating mode (i.e. economic operation air
regulators closed).
The exchanger vents are accessible from the area of the firing chamber (alternatively, if
you remove the smoke pipe). If your fireplace stove is equipped with partitions, you need
to remove them.
6.4. Sealing lines and tapes
Contact areas of doors and glass (or other parts of the heating device) are provided with a
special glass-ceramic sealing line (tape) that is resistant to high temperatures. We
recommend you to check the tape for integrity, and have it replaced if necessary.
After some time, any newly installed sealing tape lays flat so it is recommended to check
the tightness (the glass tightly installed in the door construction) after approx. 3 months of
usage. If you find any release, tighten the glass holders (carefully!)
6.5. Spare parts
In case of repair, use only original spare parts recommended by the manufacturer, see
Chapter 10.3 (Recommended spare parts). Identify the spare part with use of the Technical
Card (a part of the supply).
7. WHAT TO DO IF... ...Do you do it yourself?
Problem Cause Corrective action
Chimney or smoke flue sealing
(malfunction, “false” air is being
added).
Contact a chimney sweep (ask them to check the chimney).
For example, new sealing for the chimney door is needed.
Adjust the positions of smoke pipes or replace them if
damaged.
Chimney effect bad or not working Ask the chimney or fireplace stove specialist technician for
inspection to find out the reason and the solution (e.g.
cleaning the chimney, remove the smoke flue reduction
elements, higher chimney, more air in the room, etc.
The door of another heating device
connected to the same chimney is
open
Shut the door
Chimney cleaning holes are open. Close the cleaning holes
Smoke flue elements or other parts
of the heating system are dirty or
clogged
See 6.1.
Cleaning
Insufficient fresh air supply
See 4.9.
External combustion air supply
system
External combustion air supply system
Worsened weather conditions See 5.5.
Operation during temporary period and at
worsened weather conditions
Malfunction (weak fire, weak chimney effect) or
excessive smoke during reloading or during the firing
Wrong type of fuel was used for
burning
Provide proper kind of fuel, see 2.2.
Fuel
14 15
Wrong position of the fuel inside Not
enough fuel to set fire
Add more logs, see 5.2.
Setting the fire
Primary air supply inlet is closed Open the primary air regulator or turn down the secondary air
regulator, respectively
The exchanger cools the hearth too
long.
Provide the exchanger output with a pump switching
thermostat; preset the temperature approx. 55 °C. Switch
some appliances (heating bodies) off. Install a
thermoregulation valve, e.g. ESBE
Inadequate requirement on the heat
capacity (performance of the
fireplace stove is too low)
Contact the specialist Reduce the heat loss (for example,
provide better heat insulation)
Smoke flues and fireplace stove are
dirty
See 6.1.
Cleaning
Chimney effect is too low See 4.
INSTALLATION AND CONNECTION TO THE
CHIMNEY
Impossible to heat up the fireplace stove within
expected time
Fireplace stove is not operated
correctly
Heating device adjustment is not optimal, see 2.1.
Fuel
quantity and firing process adjustments
Fireplace stove is not operated
correctly
Heating device adjustment is not optimal, see 2.1. Fuel
quantity and firing process adjustments
Ashpan door not closed properly Shut the door
Door or ashpan sealing is
damaged
Replace the door sealing
Excessive
performance of
the fireplace
stove
Excessive chimney effect See 4.
INSTALLATION AND CONNECTION TO THE
CHIMNEY
Chimney effect is too low See 4.
INSTALLATION AND CONNECTION TO THE
CHIMNEY
The fireplace
stove
produces
odour and
smoke
Protective paint is being hardened, or
the fireplace stove is dirty, dusty
Allow the paint hardening process finish – the smoke and
odour will disappear in a short time / while cold, clean the
device outside
Sometimes is difficult to find the
reason but, usually one of the
following is found: wrong type of
fuel, wrong adjustment of the firing
process, weak or temporarily weak
chimney effect, door sealing loosen
Rule: Clean the door from time to time (depends on the type
of the fuel used), see 5.4. . If coal cakes are used, the door
needs cleaning more often than with wood
Chimney effect is too low See 4.
INSTALLATION AND CONNECTION TO THE
CHIMNEY
Too much fuel in the firing area Only load correct quantity, see 2.1.
Fuel quantity and firing
process adjustments and 5.3.
Feeding the fire
Window is getting dirty
Wet fuel was loaded. Use only well-dried fuel, see 2.2.
Fuel
Heat processing surfaces of the
exchanger are clogged
Clean them – use the brush
The fireplace stove is not operated at
sufficient performance , economic
operation is preset (air regulators are
half-closed)
Allow higher performance – open the air regulators
The exchanger
performance is
insufficient
The water pressure in the system is
not sufficient (not enough water)
Check the water pressure (water volume) and re-pressurise
the system (refill the water)
Heating
system is
overheated
The consumption of the heat
produced by the heating system is
low
Check the appliances (check the radiators they should be
open), check the pump for correct function. Contact the
specialist company.
8. FREQUENT PROBLEMS AND QUESTIONS
8.1. Cracked (released) fireclay (vermiculite) brick in the burning area
It is emphasised that cracked fireclay bricks do not lose their function unless they have
fallen out, so there is no reason to replace them while cracked only. In case of replace
needed, order the components at your sales representative or manufacturer’s address.
Please specify the type and the serial number and the fireclay ID number (see the
Technical Card).
Procedure
If you need to replace the side bricks, remove the upper partition or remove the
fireclay holders and take the damaged brick away. Sometimes, you need to remove the
cast grate with bricks at the bottom. For the installation, use the same procedure (reverse).
Make sure you place the components back in exact positions (follow the Technical Card).
Caution! Do not put the fireplace stove in operation if (even a part) of the lining within the
burning area falls out. There is danger of burning the construction through.
8.2. Broken glass
The door glass is made of special glass-ceramic material, characteristic with top heat
resistance. Do not use standard window glass!
Procedure There is no need to dismount the whole door. You should only unscrew the
holders and remove the glass then easily. When you install the new piece, make sure the
new glass is seated evenly. The contact surface between the glass and the door must be
provided with a sealing tape. Do not replace the sealing tape if it is in good condition.
Tighten the glass holders back slowly and carefully to avoid cracking the new glass by
excessive tension.
Caution! Some types of the fireplace stove are not provided with the sealing tape along the
whole perimeter.
8.3. Partitions to control the chimney effect
To clean the fireplace stove or replace fireclay (vermiculite) bricks, first remove the
movable partitions (if installed, see Technical Card). This way, you make you way to the
cleaning or replacement job. Keep in mind that some types of the partitions are designed
for holding the bricks at the position as well. Make sure you do not tilt them or let them fall
out and break. Install them back in their original positions.
Disassembly Lift the movable partition on one side a bit this way, the other end is
lowered. Move the partition aside to allow taking it out of the device.
Assembly: Use the same procedure (reverse order). Insert the partition into the device and
find the previous position. Check the final position with the Technical Card!
8.4. Cracked side tile
During transport, operation or for other reasons, tiles designed for the fireplace stove lining
may be damaged. The tiles (or metal panels) are stuck in the lining by pressure from
special springs.
Disassembly Knock on the tile slightly (use the palm of your hand) to move it to the edge
(right or left). Make sure the tile does not fall down or cracks by the tension from the spring
released. Start the disassembly from the tile in the middle or from the tile leaned against
the lining from two sides.
Assembly: Start with the bottom or upper tile. Insert the tile in its original position (from the
right or left), then get through the power produced by the spring. To do so, the best way is
to hold the tile with both hands, push it to get in contact with the edge of the fireplace stove
and, after that, knocking on the tile with you palm (gently!), move it in its correct position.
(Sometimes you need to produce a bit more than gentle knocking). Make sure the tile is
positioned properly the same overlap on both sides. The tile to be seated in the middle is
installed the last.
16 17
Caution! If during the operation any part of the lining gets loose by material dilatation, it is
recommended to increase the spring force.
8.5. Replaceable exchanger (option)
For assembly or disassembly of the exchanger or blind element installation, follow the
procedure below:
Disassembly Disconnect the exchanger from the heating system, unscrew the nuts (use a
wrench), and remove the exchanger.
Assembly:
For the assembly, follow the same procedure in reverse order. Make sure the
contact surface between the exchanger (or blind element) and the fireplace stove casing is
clean – remove residual parts of the sealing (if present). Provide undamaged sealing under
the exchanger (or blind element). Tighten the nuts evenly to provide good tightness along
the whole exchange (blind element) flange.
9. PRODUCT LIABILITY AND SERVICE
9.1. General
Providing that all directions and recommendations in the Instructions for Installation,
Operation and Maintenance are respected, the manufacturer (supplier), company HAAS +
SOHN Rukov s.r.o. provides guarantee for 24- month period from the takeover for
parameters and characteristics of the product as specified in relevant technical standards,
in the Instructions and the data shown in the nameplate.
9.2. Conditions for guarantee
The guarantee covers free-of-charge repair of the fireplace stove or parts or components
(the subject of complaint, if any) providing that the cause of the defect is defective material
or craftsmanship.
9.3. Guarantee and post-guarantee service
Guarantee and post-guarantee service is provided by importer companies or contractual
partner service institutions.
9.4. Claim rejected
The warranty is not related to damage or defects of the device or its components caused
by:
- Contact with chemical substances or physical contact causing damage during the
transport; improper storage; erroneous installation or operation in an improper manner
(for example, cooling with water, dirt from food, water condensate, etc.)
- Wrong product installed (overheating or under-heating in the room)
- Construction and legal requirements not adhered
- Wrong installation or connections
- Poor or too strong chimney effect (the connections must be in conformity with the
standards currently in force)
- Unauthorised alteration or additional modification of the heating system, especially the
firing area or smoke flue system
- Unauthorised persons interference (service work by unauthorised persons)
- Instructions for operation not adhered
- Additional built-in accessories or spare parts not manufactured by HAAS + SOHN
Rukov s.r.o.
- Use of inappropriate kind of fuel
- Erroneous operation, device overload (e.g. the ashpan door open) resulting in
damaged construction (e.g. burnt-through partitions, construction deformation, etc.)
- unprofessional manipulation, mechanical damage by excessive mechanical force
- Lack of proper maintenance or use of inappropriate cleaning agents
- force majeure (floods, etc.)
9.5. How to make a claim
Send a written claim to your sales person, by letter, fax or e-mail. Please specify the
product model, year of manufacture and serial number. (the data from the name plate, at
the rear) It is recommended to copy the nameplate data in the Table below. This way, you
can find it easily whenever needed.
HAAS+SOHN Rukov s.r.o, SNP 474, 408 01 RUMBURK, CZ
FIREPLACE STOVE TYPE
SERIAL NUMBER:
YEAR OF MANUFACTURE:
OUTPUT PERFORMANCE:
If you make a claim, kindly provide your address, phone number and description of the
defect. Ask the seller for guarantee at the purchase. The service centre shall deal with the
problem in shortest time, suggesting the place and time of the service action to the
customer. In case of request on the product replacement or purchase contract made void,
the respective provisions of the Civil Code and the Claim Code will be applied.
9.6. How to order spare parts
At any order, kindly specify the type of the fireplace stove, the year of manufacture and the
serial number of your product. For the spare part identification, follow the Technical Card
(state the name of the part or its ID or position in the drawing). You can order spare parts
and accessories at your local distributor – dealer, or at our partner organisation.
10. MISCELLANEOUS
10.1. Accessories supplied with the fireplace stove
The fireplace stove has been delivered with accessories: protective glove to touch the
regulating elements, ashpan drawer, Instructions for Installation , Operation and
Maintenance, Guarantee and Technical Card, a steel brush (for the exchanger cleaning)
only with the fireplace stove provided with a removable exchanger).
10.2. Special accessories (on order)
1. Smoke flue pipes, with/without block, diameter 150 mm and 130 mm (length 0.25
m;0.5 m; 1m)
2. Smoke flue elbow with/without cleaning hole, diameter 150 mm and 130 mm (90°, 45°)
3. Chimney stress ring, diameter 150 mm and 130 mm
4. Baskets
5. Fireplace tooling (special offer)
6. Cleaning agent (glass)
7. Blind element
8. Cooling exchanger (loop)
10.3. Recommended spare parts
Spare parts available on order
1. Fireclay brick shapes and VERMICULITE boards for the firing area
2. Ashpan drawer
18 19
3. Stoking door glass
4. Cast grate
5. Sealing tapes
6. Repair spray
7. Sealing tape glue
8. Lining
9. Blind element
10. Decorative and regulating elements (rods, handles, regulators)
11. Steel brush (for the exchanger cleaning)
12. Warm water exchanger (without a cooling loop)
10.4. Package and waste disposal
The fireplace stove is supplied on a wooden transport pallet and protected with wooden
crate. The fireplace stove is protected against weather with PE foil. Stabilised position and
integrity of the package for the period of storage and transport is provided by means of
metal or plastic tape.
Package material disposal Use the wooden crate and the pallet for burning. Sort the
steel tape for the waste collecting point. Sort the PE foil to be recycled.
Fireplace stove disposal after the service life: For the disposal after the service life, sort
the fireclay, vermiculite panels, glass and sealing tapes as solid communal garbage. Sort
the metal corpus and other metal components for the waste collecting point.
10. 5. ES Declaration of Conformity and CE Certificate
ES Declaration of Conformity is issued with all products, following from the Report on initial
type testing in compliance with CSN EN 13 240:2002/A2:2004 and CE certificate: The
Report on initial type testing and the CE Certificate are in accord with Directive
89/106/EHS, issued by a notified body. Notified testing institutes (verification of the
products manufactured by HAAS + SOHN:
Strojírenský zkušební ústav, s. p. (Testing Institute of Engineering), ES 1015, AO 202,
Hudcova 56 b, 621 00 Brno, Czech Republic.
Rhein – Ruhr Feuerstätten Prüfstelle (RRF) Essen, Germany.
The manufacturer declares that the fireplace stove as specified is in conformity with the
requirements of the Directive 89/106/EHS. Under the standard conditions, the product is
safe providing that it is operated and used for the purpose as designed by the
manufacturer.
The manufacturer guarantees the conformity of all products in the market with the technical
specifications and identical requirements.
10. 6. HAAS+SOHN Rukov s.r.o Products and Manufacturing
Programme
Company HAAS+SOHN Rukov is a Czech company with participation of foreign capital.
The company specialises in manufacture and sale of fireplace sets and fireplace inserts.
The products are designed for burning wood, eco-wood cakes or coal cakes (optional).
Manufacturing Programme
- Fireplace stoves
- Fireplace stoves with warm water exchanger
- Tiled fireplace stoves
- Tiled fireplace stoves with warm water exchanger
- Fireplace inserts and fireplace sets
- Fireplace inserts with warm water exchanger and fireplace sets
MISCELLANEOUS
- Fireplace tooling and baskets
- Accessories (smoke flue pipes, elbow pieces, chimney stress rings, etc.)
- Other special products
10. 7. Caution!
The above recommendations and technical specifications follow from the requirements in
technical standards applied for the certification of the product (EN 13 229:2005+A2: 2004)
in conformity with Directive 89/106/EEC.
11. SUPPLEMENTS
1. Technical Card and Guarantee
2. Supplement 1
o CLEARANCE BETWEEN THE FIREPLACE STOVE AND THE
SURROUNDINGS
3. Supplement 2
o Example of position of the protective barrier and smoke flue
o Passage of the smoke flue through the fireproof wall
o Direct connection of the device to the chimney (clearance from the wall)
o Examples of correct and wrong installations of the smoke flue in the chimney
body hole
4. Supplement 3
o General scheme: heating system 1 Protection against overheat in case of
electric power failure with use of a cooling
exchanger (loop).
5. Supplement 4
o General scheme: heating system 2 Combined heating system: Electric boiler
+ Fireplace stove, divided in two heating
branches A and B with use of a back-up
system UPS 300.
20 21
EXAMPLE: PROTECTIVE BARRIER
FOR THE HEATING DEVICE AND SMOKE
FLUE (dimensions in mm)
CLEARANCE BETWEEN THE FIREPLACE STOVE AND THE SURROUNDINGS
MINIMUM CLEARANCE
A > = 800 mm
B > = 200 mm
PASSAGE THROUGH THE SMOKE FLUE
WALL OF FLAMMABLE MATERIAL
(dimensions in mm)
1 – Wall
2 – Smoke flue system
3 – Cover (fireproof, non-metal)
4 – rosette
5 – Protective pipe (fireproof, non-metal)
6 – Insulating filler I (fireproof, e.g. glass fibre)
7 – Insulating filler II (fireproof, e.g. stove clay)
ČSN 06 1008 : 1997
1
Ceramic (metal) insert
2 – Metal chimney body
3 – Chimney walling
4 – Metal smoke flue system
5 – Hole in the chimney body
6 – Sealed branch to the chimney body
7 – Shim, fixed to the body with metal tapes
8 – Dilatation gap between
the brick shape and the
chimney walling
CORRECT – SEE c, d WRONG – SEE a, b
Comment: ČSN 73 4201 : 2008
supplement 2
DIRECT CONNECTION OF THE
DEVICE TO THE CHIMNEY AND
CLEARANCE FROM THE WALL
1 – Protective barrier protecting the rating device and
smoke flue against heat
2
Feeding hole and ashpan hole
SMOKE FLUE CONNECTION IN THE
CHIMNEY BODY HOLE
supplement 1
22
23
General scheme: heating system 1
Protection against overheat in case of electric power failure
with use of a cooling exchanger (loop).
supplement 4
supplement 3
Inlet and reverse piping (Warm water)
Cooling exchanger piping
Cable CYKY 3Cx1,5
Flow direction
Legend:
1. Warm water exchanger
2. .Circulating pump
3. .Expansion tank
4. Heating body
5. .Discharge valve
6. .Safety valve
7. Thermostatic valve ESBE, warm water 25 –
60 °C
8. Ball cock
9. .Closing filter
10. .Pressure gauge
11. Deaerating valve
12. Waste
13. .Cooling exchanger (look)
14. Safety warm water valve
General scheme: heating system 2
Combined heating system : Electric boiler + fireplace
stove , branches A and B, backup UPS 300.
Separating valves – heat circuits I- II:
Designed for separation of the heat circuits A
and B.
Heat circuit B: A part of the heat circuit.
Only for the fireplace stove.
Heat circuit A: General heat circuit. Both
devices in operation at a time.
Instal a thermoregulating valve , e.g .ESBE
TV25, opening temperature 60oC. When this
temperature is reached, the valve opens , and
the liquid from the heat system B (or A+B) is
let in the fireplace stove circuit (3-1).
The
inlets 1 and 3 of the valve are open – to
provide minimum temperature required for the
reverse water.
The recommended temperature gradient is 75-
60 °C. To provide this, the following
conditions must be met:
B – Connection to the parts of the system
A – connection to the general heating system
12
Backup UPS 300
11. Thermostat
10. Deaerating valve
9
Electric boiler
8. Pressure gauge
7. Ball cock
6. Closing valve
5. Safety valve
4. Thermoregulation valve , e.g. ESBE TV25
3
Expansion vessel
2. Circulating pump
1. Fireplace stove and exchanger
LEGEND:
Warm water inlet piping
Warm water reverse piping
A – A)Warm water output
B
B)
Reverse water input
C – Input of cooling water in the cooling exchanger (loop)
D – Cooling water output (into the sewage system)
The cooling exchanger (look) , the protection against
overheat (13), must not be used for other purposes than as
designed!
Connection to cold water system
24
25
Printed: TISKÁRNA ŘEHÁK Česká Lípa, Czech Republic, Tel.: 487 853 897
1

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Haas-Sohn GRAND MAX PLUS II 11 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Haas-Sohn GRAND MAX PLUS II 11 in de taal/talen: Engels als bijlage per email.

De handleiding is 0,66 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info