7. WHAT TO DO IF... ...Do you do it yourself?
Problem Cause Corrective action
Chimney or smoke flue sealing
(malfunction, “false” air is being
added).
Contact a chimney sweep (ask them to check the
chimney). For example, new sealing for the chimney
door is needed. Adjust the positions of smoke pipes
or replace them if damaged.
Chimney effect bad or not
working
Ask the chimney or stove specialist technician for
inspection to find out the reason and the solution
(e.g. cleaning the chimney, remove the smoke flue
reduction elements, higher chimney, more air in the
room, etc.
The door of another heating
device connected to the same
chimney is open
Shut the door
Chimney cleaning holes are
open
Close the cleaning holes
Smoke flue elements or other
parts of the heating system are
dirty or clogged.
See 6.1.
Insufficient fresh air supply See 4.7.
Worsened weather conditions See 5.5.
Malfunction (weak fire, weak chimney effect) or excessive smoke
during reloading or during the firing
Wrong type of fuel was used for
burning
Provide proper kind of fuel, see 2.2.
Wrong position of the wood logs
inside Not enough fuel to set fire
Add more logs, see 5.2.
Impossible to heat up
the fireplace insert
within expected time
Primary air supply inlet is closed Open the primary air regulator or turn down the
secondary air regulator, respectively
Inadequate requirement on the
heat capacity (performance of
the fireplace insert is too low)
Contact the specialist Reduce the heat loss (for
example, provide better heat insulation)
Smoke flues and insert are dirty See 6.1.
Chimney effect is too low See 4.
The room is not heated
enough
Fireplace insert is operated in a
wrong manner
Heating device adjustment is not optimal, see 2.1.
Fireplace insert is operated in a
wrong manner
Heating device adjustment is not optimal, see 2.1.
Ashpan door is a bit open Shut the door
Door or ashpan sealing is
damaged
Replace the door sealing
Excessive
performance of the
fireplace insert
Excessive chimney effect See 4.
Chimney effect is too low See 4.
odour
and
smoke
Protective paint is being
hardened/ the stove is dirty,
dusty
Allow the paint hardening process finish – the smoke
and odour will disappear in a short time / while cold,
clean the device outside
Sometimes is difficult to find the
reason but, usually one of the
following is found: wrong type of
fuel, wrong adjustment of the
firing process, weak or
temporarily weak chimney effect,
door sealing loosen
Rule: Clean the door from time to time (depends on
the type of the fuel used), see
5.4.
. If coal cakes are used, the door needs cleaning
more often than with wood
Chimney effect is too low See 4.
Too much fuel in the firing area Only load correct quantity, see 2.1. and5.3.
Window is getting dirty
Wet fuel was loaded Use only well-dried fuel, see 2.2.
8. FREQUENT PROBLEMS AND QUESTIONS
8.1. Cracked (released) fireclay (vermiculite) brick in the burning area
It is emphasised that cracked fireclay bricks do not lose their function unless they have fallen out, so
there is no reason to replace them while cracked only. In case of replace needed, order the
components at your sales representative or manufacturer’s address. Please specify the type and the
serial number and the fireclay ID number (see the Technical Card).
Procedure If you need to replace the side bricks, remove the upper partition or remove the fireclay
holders and take the damaged brick away. Sometimes, you need to remove the cast grate with
bricks at the bottom. For the installation, use the same procedure (reverse). Make sure you place the
components back in exact positions (follow the Technical Card).
Caution! Do not put the stove in operation if (even a part) of the lining within the burning area falls
out. There is danger of burning the construction through.
8.2. Broken glass
The door glass is made of special glass-ceramic material, characteristic with top heat resistance. Do
not use standard window glass!
Procedure: There is no need to dismount the whole door. You should only unscrew the holders and
remove the glass then easily. When you install the new piece, make sure the new glass is seated
evenly. The contact surface between the glass and the door must be provided with a sealing tape.
Do not replace the sealing tape if it is in good condition. Tighten the glass holders back slowly and
carefully to avoid cracking the new glass by excessive tension.
Caution! Some types of the fireplace insert are not provided with the sealing tape along the whole
perimeter.
8.3. Partitions to control the chimney effect
To clean the insert or replace fireclay (vermiculite) bricks, first remove the movable partitions (if
installed, see Technical Card) . This way, you make you way to the cleaning or replacement job.
Keep in mind that some types of the partitions are designed for holding the bricks at the position as
well. Make sure you do not tilt them or let them fall out and break. Install them back in their original
positions.
Disassembly: Lift the movable partition on one side a bit – this way, the other end is lowered. Move
the partition aside to allow taking it out of the device.
Assembly: Use the same procedure (reverse order). Insert the partition into the device and find the
previous position. Check the final position with the Technical Card!
13 14
7

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Haas-Sohn ELSASS II RUIVONA bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Haas-Sohn ELSASS II RUIVONA in de taal/talen: Engels als bijlage per email.

De handleiding is 0,32 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info