PROMIX30_v2 VELLEMAN
5
5. Connections
• Make sure the power switch (p.2 #10) is set to “OFF” before making any connections.
• Use only high quality audio cables to minimize sound quality losses.
• Connect your amplifier to the MAIN output (p.2 #22) and any recording device to the REC output (p.2 #21)
• Connect your microphone to the MIC input (p.2 #14) and your headphones to the PHONES output (p.2 #17).
• Connect your record players to the PHONO inputs (p.2 #25 & 27) and set the selection switches (p.2 #23 or 24) to PH.
• Connect any line signals to the LINE (LN) inputs (p.2 #26 and 28 are line inputs only ; for inputs #25 and 27 you
need to set the switches 23 and 24 to the LN side).
6. Cleaning and Maintenance
1. All screws should be tightened and free of corrosion.
2. The housing, visible parts, mounting supports and the installation location (e.g. ceiling, suspension, trussing)
should not be deformed, modified or tampered with e.g. do not drill extra holes in mounting supports, do not
change the location of the connections…
3. The electric power supply cables must not show any damage. Have a qualified technician maintain the device.
4. Disconnect the device from the mains prior to maintenance activities.
5. Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
6. There are no user-serviceable parts.
7. Contact your dealer for spare parts if necessary.
7. Technical Specifications
Power supply max. 230VAC/50Hz
Microphone input 1.5mV / 2kΩ / balanced
Phono inputs 3mV / 47kΩ
Line inputs 150mV / 27Ω
Equalizer high +12dB / -12dB
Equalizer bass +12dB / -12dB
Master output 0dB / 1V / 600Ω
Record output 0dB / 1V / 600Ω
Frequency response 20Hz~20kHz +/-2dB
Distortion 0.02%
S/N ratio >80dB
Headphones impedance 160Ω
Dimensions 280 x 200 x 112mm
Total Weight 2.7kg
Fuse F 0.5A, 250VAC (5 x 20mm) (order code FF0.5N)
The information in this manual is subject to change without prior notice.