SCM54E is safely maintaining the battery at a full charge when the
green light is on. The battery is ready. Simply remove the battery
clamps and set them on the working surface clear from the other
batteries and battery clamps. You can now load test the battery if
necessary.
1.When the battery clamps are accidentally disconnected
while charging is in effect, the SCM54E will shut off.
Green indicator light will go flashing. Simply reconnect
the battery charged.
2.Do not disconnect the battery while charging at 5Amps.
Wait for both green and red LED light on.
1. Introduction:
DHC has developed its own advanced processes and has applied
advanced technology to the development of the SCM54E Switching
Power, Digital Processing Battery Charger.
SCM54E Professional Charger provides 5 Stage Automatic, True
Pure DC current charging capacity, which not only will charge a
battery efficiently, but will also prolong the lifetime of the
requisite battery.
- GB.7-V1 -