EN
Page | 27
Example: Start in 8 hours
The mobile air conditioner is in stand-by
mode.
1. Press button “c” Timer.
2. Set the desired starting time delay
between 1 and 24 hours with
buttons “e” and “f”.
The starting time in hours appears
on the display.
3. Time shown on the display
8 hours.
As soon as the 8 hours have elapsed,
the mobile air conditioner switches on
automatically.
NOTE
The SLEEP function is disabled for the
duration of the starting time delay.
13.2 Setting the SLEEP
function
1. Start the SLEEP function with button
"a".
2. The fan runs at the lowest speed
and the temperature is controlled for
max. 8 hours:
3. 0 – 2 hours: Increase by 1°C per
hour.
4. 2 - 4 hours: Temperature is kept
constant.
5. 6 - 8 hours: Decrease the
temperature by 1°C per hour.
NOTE
The function is only available in cooling
mode.
13.3 Setting SWING functions
Setting of the air flow for a more
comfortable and better air circulation.
1. Activate the SWING function with
button “b”.
The air flow direction (louvres)
moves from left to right.
2. Fix the air flow direction (louvres) in
the respective position by pressing
button "b" again.
13.4 Installing the water
drain hose
Note that the water drain hose
connected to the mobile air conditioner
must not run higher than the position of
the hose connection on the mobile air
conditioner at any point. Otherwise,
condensation may flow back into the
mobile air conditioner and damage the
appliance.
Water connection 10 mm hose.
Disconnect the mobile air conditioner
from the mains power supply before
installing the water drain hose.
Direct water drain
(condensate drain)
(see Fig. 2)
1. Remove the screw cap and water
plug on the rear (middle) of the
appliance from the drain hole.
2. Attach the water drain hose to the
connection.
Floor tray drain
(see Fig. 3)
1. Remove the screw cap and water
plug on the rear (bottom) of the
appliance from the drain hole.
2. Attach the water drain hose to the
connection.
Route the free end of the water drain
hose into a suitable drain or container
into which the condensation is to drain.
NOTE
If the internal water tank is full, the
appliance automatically switches to
emergency stop. “W.F” lights up on the
display.
13.5 Set fan speed
Set the fan speed between low, medium
and high with button “g”.
13.6 Description of the
operating modes
Select the mode between cooling,
ventilation, dehumidification and AUTO
with button “d”.