Operator requirements
The operator must carefully read the Operating Instructions
before using the appliance.
Qualification
No special qualification is necessary for using the appliance
apart from detailed instruction by an expert.
Minimum age
The appliance can only be operated by persons over 18 years
of age. An exception includes youngsters operating the
appliance within their professional education to achieve
necessary skills under trainer's supervision.
Technical specifications
310/10/50 PRO
Connection: 230 V/50 Hz
Engine power: 2100 W/P1
Air jet capacity: 50 l
Suction power: 295 l per minute
Effective volume delivered: 210 l per minute
Cylinders: 1
Revolutions: 2800 revs per minute
Max. pressure: 10 bar
Weight: 35 kg
Article No. 75505
Transport and storing
The appliances are mobile and can practically be used
everywhere. If the compressor is wall-mounted, the minimum
distance of 30 cm must be kept to ensure appropriate cooling.
Appliances must necessarily be transported in a vertical
position; otherwise, oil will run out of the air hole of the engine
case. Prevent any hits to fittings.
Residual risks and protective measures
Electrical residual risks:
1. Direct electrical contact:
Risk of electric shock
To be used in electrical networks with a safety switch
against stray current (RCD-FI 30 mA) only.
2. Indirect electrical contact:
Risk of electric shock
To be used in electrical networks with a safety switch
against stray current (RCD-FI 30 mA) only.
Thermal residual risks:
1. Burns, chilblains:
Contact with the cylinder head and pressure lines
may cause burns.
Avoid both of these construction elements.
Exposure to noise:
1. Hearing damage:
Long stay in the immediate vicinity of the appliance
may damage hearing.
Wear headphones.
Neglecting the ergonomic principles:
1. Human behaviour / erroneous behaviour:
Compressed air current may lead to serious injuries.
Never hold the current in body holes.
Compressed air may cause tanks and tyres to break.
Do not exceed the max. filling size.
Installation and first start-up
Pic.2+3+4:
1. Remove the oil tank transport protection (if applicable)
pic. 3
2. Insert the attached oil gauge or plug instead.
3. Oil gauges or plugs, pic. 4 (failing to do so will increase
pressure in the engine case and oil will spirt).
Electrical connection; grounded connections to be used
only:
a) 230 V appliances are supplied with plugs fitted with a
ground contact
The following must be considered as far as 230 V
appliances are concerned:
If a too long extension cable with a too small cross-section
is used, voltage will drop, which may result in a more difficult
starting and increased engine load. If possible, we
recommend connecting the engine cable directly to the outlet
and using longer air hoses (another measure: see the winter
operation).
Recommended cable cross-section values for all 230 V
appliances:
Length within app. 10 m = 1.5
2
mm
Length within app. 20 m = 2.5
2
mm
Oil level check (for oil compressors only):
Oil may leak when the appliance is transported. Please check
the oil level on the aperture or using an oil gauge (more
information at a similar description with a picture)
Winter operation of compressors
The following must be considered in colder seasons
when operating the compressors: Oil gets thicken and its
viscosity increases with low temperatures in the engine case.
This makes first appliance starting before warm-up more
difficult. Proceed as follows when facing difficulties:
1. Reduce any pressure in the air jet to zero.
2. Open the drainage screw on the bottom part of the air
jet.
3. Unless being absolutely necessary, do not use any
extension cable!
4. Switch on the compressor and let it run (without any
extension cable). With the drainage screw open, let it run
for app. 2-3 minutes to enable air to leak and thus
pressure to reduce. The appliance will warm in these 2-3
minutes to enable further operation.
5. After 2-3 minutes, close the drainage screw. The air jet
can now be filled and pressure increased.
6. Change oil – use 5W40 synthetic oil for light running
or, as alternative, SAE 80 gearbox oil.
7. If the compressor does not start despite all the effort, put
it out of operation for half an hour to one hour in a
tempered room to warm up.
8. Please contact the customer service centre for more
difficulties.
All documents necessary for proper operation are
included in the supply (see the simple regulation for
pressure vessels). When used for industrial purposes,
an inspection is necessary before the appliance is used
for the first time under the operating safety regulation.
Safety instructions for first start-up
Procedure
1. Switching compressors on and off:
The On/Off button (rotary and pull switch) is up on the
pressure switch cover at all compressors. Switch
positions are marked as "0" and "I". When plugging, the
switch must be in the "0" position, then the appliance
15
15

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Gude Pro 310-10-50 PRO 75505 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Gude Pro 310-10-50 PRO 75505 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans als bijlage per email.

De handleiding is 0,9 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info