Max. transported volume Max. transport height
Weight Noise
Use as designated
The pump has exclusively been designed to pump clean
w ater to supply w ater to household, in the garden, farm and in
agriculture. If provisions of the generally valid regulations or
provisions of these Operating Instructions are not followed,
the manufacturer cannot be held liable for any damage.
The complete Operating Instructions must be read before
using the appliance for the first time. If there are any doubts
regarding the connection and operation of the appliance,
please contact the manufacturer.
Residual risks and protective measures
Ele ctrical residual risks
Risk
Description
Protective measure(s)
Direct
electrical
contact
Electric shock
Safety sw itch against stray
current FI
Indirect
electrical
contact
Electric shock
through
medium
Safety sw itch against stray
current F
Disposal
Disposal instructions are illustrated in the form of pictograms
on the device or packaging. Description of the pictograms is
given in "Identification" chapter.
Disposal of transport packaging
Packaging protects the device against damage during
transport. Packaging materials are usually selected according
to their effect on environment and disposal methods and can
therefore be recycled.
Returning of the packaging back to circulation saves
resources and costs for packaging disposal.
Parts of the packaging (e.g. foil, styropor) may be dangerous
for children. Risk of suffocation!
Keep these parts of the packaging out of reach of children
and dispose as soon as possible.
Operator requirements
The operator must carefully read the Operating Instructions
before using the appliance.
Qualification:
No special qualification is necessary for using
the appliance apart from detailed instruction by an expert.
Minimum age
The appliance can only be operated by persons over 16 years
of age. An exception includes youngsters operating the
appliance w ithin their professional education to achieve
necessary skills under trainer's supervision.
Training
Using the appliance only requires appropriate instructions by
a professional or reading the Operating Instructions. No
special training necessary.
Technical specifications
HWW 1000 P HOME PUMPING STATION
Voltage/frequency
230 V/50 Hz
Engine power
1,000 W
Max. suction height
8 m
Max. transported volume
3,500 l per hour
Max. transport height
44 m
Hose connection
1‘‘ IG
Tank capacity
20l premium steel tank
Protection type
IPX4
Max. water temperature
35 °C
Noise
L
WA
90 dB
Weight app.
12 kg
Order No.
06026
Transport and storing
When storing the appliance for winter, it is necessary
to make sure there is no water in the appliance as frost could
be cause the appliance to get damaged.
Unplug the pump every time it is to be transported!
The pump must be emptied to the full extent and stored in a
place protected against frost. Rinsing the pump with
appropriate oil (e.g. vegetable oil) may prevent, to some
extent, mechanical sealing from sticking.
Assembly first start-up
Pre-filter and screen for impurities
If w ater contains sand, the pump must be fitted w ith a pre-
filter (can be supplied as an accessory) betw een the suction
hose and the pump body (pic. E). A suction branch w ith a
reverse valve and a screen for impurities must necessarily be
used. If sand enters the slip strip sealing (engine pump
transmission shaft), it can get damaged! This w ould represent
damage by the appliance user, therefore, not covered by the
w arranty not even in the w arranty period.
Safety instructions for first start-up
Caution: The pump must not run empty.
Do not use the pump to pump drinking w ater!
The user is responsible to third persons as far as using the
pump (pumping station, etc.) is concerned.
To be used on connections with a safety switch against
stray current (FI) only!
Before putting the appliance into operation, a qualified
electrician must check w hether the required electrical safety
equipment is in place.
Electric connection by means of a socket.
Check the voltage. The technical details on the label must
correspond to the electric netw ork voltage. If the pump is used in
ponds, w ells, etc. and in appropriate w ater equipments, standards
applicable in the countries w here the pump is used must
necessarily be adhered to.
Electric pumps used outside must be fitted w ith a rubber electric
cable, H07RNF type, according to DIN 57282 or DIN 57245
standards.
When the pump is being operated, no people or animals
are allowed to stay or plunge in the pumped liquid (e.g.
swimming pools, cellars, etc.).
The pumped liquid temperature must not exceed +35 °C. If
an extension cable is used, it must exclusively be made out
of rubber, H07RNF type, according to DIN 57282 or DIN
57245 standards. A pump that is plugged must never be
touched, lifted or carried by cable. It is necessary to make
sure the connecting socket is always in a distance from
w ater and moisture and the plug is protected against
moisture.
11
11

Hulp nodig? Stel uw vraag in het forum

Spelregels
1

Forum

Gude-HWW-1000-P-INOX-06026

Zoeken resetten

  • Hallo, heb een Gude Gs4002P gekocht nu bijna 2 jaar oud. Gisteren in stopcontact (thuis 220 volt)gestopt maar slaat niet méér aan?
    Weet iemand wat ik kan doen ?

    Gr.Joen Gesteld op 18-5-2022 om 09:47

    Reageer op deze vraag Misbruik melden
  • mijn gude hydrofoorpomp HWW 1000e slaat na het vullen van de waterreservoirs niet meer af wat is het probleem? met vr. gr. Wim Mulder Gesteld op 29-10-2020 om 12:22

    Reageer op deze vraag Misbruik melden
  • hoe kan ik een tuinpomp van Gude gd 1000l die is afgeslagen door de beveiliging en weer wil resetten met de aan/uit knop om de pomp te kunnen gebruiken. Gesteld op 12-7-2020 om 17:29

    Reageer op deze vraag Misbruik melden
  • hoe kan ik een gude gd 1000 l tuinpomp die door de beveiliging is afgeslagen weer resetten met de aan/uit knop
    Gesteld op 12-7-2020 om 17:25

    Reageer op deze vraag Misbruik melden
  • Gisteren een HWW 1000 P Gekocht Hoe moet ik de Drukverhogen Gesteld op 9-4-2020 om 17:52

    Reageer op deze vraag Misbruik melden

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Gude HWW 1000 P INOX 06026 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Gude HWW 1000 P INOX 06026 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans als bijlage per email.

De handleiding is 3,77 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info