Electric safety:
DANGER! Electric shock!
Risk of injury by electric shock!
Pull the plug out of socket before fill of the pump, after
switching it off, at repair removal and before
maintenance.
Operate the appliance on connectors with an earth-
leakage circuit-breaker (RCD)!
Please consult with an electrician.
Information on the type label must correspond to information
of the electric network.
Protect the cable against high temperatures, oil and sharp
edges.
General instructions:
Before using the pump, always execute a visual inspection
to detect any damage of the pump, especially the line cord
and plug.
A damaged pump must not be used.
In case of any fault, have the pump checked in a service
department of GUDE or at an authorised electrician.
Do not expose the pump to rain and do not use it in a moist or
wet environment.
To prevent the pump from running dry, please make sure the
end of the suction hose was always plunged in the pumped
medium.
Fill the pump with the pumped liquid until it overflows before
each starting!
When the pump is used as a home pumping station, local
regulations of a water company need to be observed.
Moreover, provision of the DIN 1988 standard must be
obeyed.
Behaviour in emergency
Provide first aid of a corresponding nature and level of injury
and call qualified medical help as soon as possible.
Rest the injured person in peace and in a manner he/she did
not sustain any other injury.
Appliance use as designed
The pump is solely designed to pump clear water to supply
water to a house, garden, court and agriculture. If the
generally binding regulations and provision of these
Instructions are not observed the producer cannot be held
liable for any damage.
Residual risks and protective measures
Electric residual risks
Threat Description Protective measures
direct electric
contact
electric shock earth-leakage circuit-breaker
indirect
electric
contact
electric shock
through
pumped
medium
earth-leakage circuit-breaker
Disposal
The disposal instructions are based on icons placed on the
package or appliance. The description of individual meanings
can be found in the “Marking on appliance“ chapter.
Handling requirements
The operating staff must carefully read and understand the
Operating Instructions before using the appliance.
Qualification
Apart from the detailed instructions by a professional, no
special qualification is necessary for appliance using.
Minimum age
Persons over 16 years of age can only work on the appliance.
An exception includes use by youngsters if the appliance is
used under supervision of trainer within occupational
preparation and its use serves to reach the necessary
knowledge.
Training
Appropriate training executed by a competent person,
knowing the Operating Instructions, is only necessary for
using of the appliance. No special training is necessary.
Technical data
HWA 1200 IC
Supply voltage 230 V / 50 Hz
P1 engine power 1200 W/P1
Max. suction lift 8 m
Max. amount pumped 3,800 l an hour
Max. head of delivery 50 m
Discharge connector 1“
Suction connector 1’’
Protection type IP 44
Water temperature 35 °C
Weight app. 12,4 kg
Product No. 94207
Transport and storing
When storing the appliance for a winter period it is
necessary to make sure there is no water in the appliance as
frost could be a cause for appliance damage.
At each transport and carrying, the appliance must be
disconnected from electric current source!
Assembly and first putting into operation
Filter and sludge screen
At pumping water with sand contents, the pump needs to be
operated with a sludge filter (available as accessory) for the
suction connector. Sand entering the mechanical seal
(propeller shaft engine - pump) would damage the pump! That
would mean, even during the guarantee time, your own fault
and the guarantee does not relate to such failures.
Safety instructions for first putting the pump into
operation
Attention: the pump must never run dry.
Do not use the pump for pumping drinking water!
The user is responsible to other persons as far as pump
(pumping station, etc.) operation is concerned.
Operate on connectors fitted with an earth-leakage
circuit-breaker only!
Before putting the appliance into operation, a competent
electrician must check that the appliance disposes of the
required electric safety elements.
Wiring is done to a socket. Check the voltage. Technical data
specified on the label must correspond with the electrical
network voltage.
If you use the pump for small lakes, wells, etc. and pumping
stations you must follow appropriate standards of the country in
which the pump is used.
Electrical pumps used outdoor must be fitted with a rubber
H07RNF-type electric cable corresponding to DIN 57282 or DIN
57245 standards.
When the pump is in operation, there must be no people
or animals in the pumped liquid (e.g. in pools, cellars,
etc.)
The temperature of the pumped liquid must not exceed +35
°C. If you use an extension cable it must be solely of rubber,
the H07RNF type, corresponding to DIN 57282 or DIN
57245 standards. Never touch, lift or carry a pump
connected to electrical network with a cable. Make sure
there is no water or moisture in the connecting socket and
the plug was protected against moisture.
31
31

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Gude HWA 1200 IC bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Gude HWA 1200 IC in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans als bijlage per email.

De handleiding is 1,04 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info