rinsed with clean water when used in very dirty water. The
switching on and off heights can differ.
Thermal fuse/engine protection circuit-breaker
The drowned pump is equipped with an engine protection
circuit-breaker. If the engine is overheated, the engine
protection circuit-breaker will automatically switch the pump
off. Cooling time is app. 25 minutes, the pump subsequently
switches on. If the engine protection circuit-breaker switches
on, it is absolutely necessary to identify the cause and
remove it (see also the “Failure searching“). The given data
cannot be used for “family style“ repairs as it requires
specific professional knowledge. You must contact the
customer service department at any failures.
Instructions step by step
Connect the water hose to appropriate pump outlet (see
the Assembly and first putting into operation).
Fix the rope, chain, etc. to the pump handle and place it
to the right place.
Put the pump “sideways“ (pic. D) to the pumped
medium. Make sure the floating switch is in the operating
position.
Plug in the pump.
Rinse the pump with clean water after work finishing.
Operation
The pump is put into operation when the plug is inserted in
appropriate socket and the floating switch is in the required
position (see the Instructions). If the pump is lifted or
transported, it is done with an assembled handle and not with
the connecting cable. If the pump is being plunged, a rope,
chain, etc. fastened to the handle need to be used if
necessary.
At muddy, sandy or siliceous soil the pump must be hung on
a rope or chain or put on a suitable wide baseplate to be able
to work plunged. Sand and other abrasive solids reduce the
service life of hydraulic parts and seal of the pump and
therefore they need to be prevented. In frost conditions, the
pump must be removed from the pumped liquid. It is
necessary to absolutely make sure the pump is not exposed
to a risk of frost. The pump must be emptied and stored at a
place protected against frost.
Floating switch positions (pic. B + C)
The operating or shutdown point of the pump can be set
with various floating switch positions. In pic. B you can see
the float cable without any fixation change with full switch
radius. The figure 1 is the working position and figure 0 the
shutdown position.
Due to appropriate fixation of the float cable, possible on the
pump handle, the switch radius can be reduced when there is
no sufficient space or at a corresponding level control. The
figure 1 in pic. C is the working position and figure 0 the
shutdown position.
Continuous operation: The floater can be hung to the side
of the pump; in this position (the floater cable points
downward), the pump runs constantly.
Important: In case of continuous operation, under no
circumstances allow the operation of the pump without
fill!
Important: If the pump is to stay out of service for a longer period of time, make sure by all means necessary that both the
pipelines and the pump itself are emptied. Protect the device against frost. The pump can only be stored entirely empty.
Failures – causes - removal
Failures Causes Removal
Engine does not start
No system voltage
Blocked pump wheel
Floating switch in shutdown position
Check the voltage
Inspect the pump wheel for foreign objects
Check the water level (pic. B/C)
Pump does not suck
Pump without water
Water level too low
Blocked pump wheel
Let the air bubbles release (pic. D)
Switch the pump off, water level must go up.
Remove the obstruction
Insufficient amount of
water pumped
Dirty tube filter
Water level quickly going down
Maximum head of delivery exceeded
Transport guide broken
Clean the tube filter
Ensure sufficient inflow
Check the transport path length
Check the transport guide
Thermal detector
switching the pump off
Dirty tube filter
Water temperature too high
Pump running continuously at maximum pressure.
Clean the tube filter and let the pump cool down
Reduce the water temperature
Make more breaks
Inspections and maintenance
Be sent with the exception of cases described below, the pump for repairs required for service.
Safety instructions for inspections and maintenance
It is always necessary to interrupt feeding (plug pulled out of socket) and make sure the pump is not going to start before any pump
maintenance.
Only a regularly maintained and treated appliance can serve as a satisfactory aid. Insufficient maintenance and care can lead to
unforeseen accidents and injuries.
Inspection and maintenance plan
Time interval Description Any other details
As needed Cleaning and rinsing out Function check of the floating switch (C/D)
11

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Gude GSX 1100 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Gude GSX 1100 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans als bijlage per email.

De handleiding is 0,54 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info