Thermal fuse
A probe automatically switching the pump off when specific
temperature is exceeded and on when the pump has cooled
down is assembled inside the electric motor. That manifold
increases the pump service life and prevents electric motor
burn-out.
Procedure:
The pump is put into operation when the plug is inserted in
appropriate socket and the floating switch is in the required
position (see the Instructions). If the pump is lifted or
transported, it is done with an assembled handle and not with
the connecting cable. If the pump is being plunged, a rope,
chain, etc. fastened to the handle need to be used if
necessary.
At muddy, sandy or siliceous soil the pump must be hung on
a rope or chain or put on a suitable wide baseplate to be able
to work plunged. Sand and other abrasive solids reduce the
service life of hydraulic parts and seal of the pump and
therefore they need to be prevented. In frost conditions, the
pump must be removed from the pumped liquid. It is
necessary to absolutely make sure the pump is not exposed
to a risk of frost. The pump must be emptied and stored at a
place protected against frost.
Attention! Important information for the customer
It is recommended to plunge or put the pump sideways in
the liquid. The body air cushion can thus be released and
the pump starts immediately working. The pump can
subsequently be stood straight.
Attention! Important information for the customer
To ensure long service life of the pump seal, we
recommend rinsing the pump with clean water in regular
intervals.
Automatic float
The float will automatically put the pump into operation when
the liquid level goes up or down. If the float cable is extended
or shortened, based on its support point, it will switch the
pump on or off due to the minimum or maximum height
required. The float cable is fixed to the pump handle with a
suitable pressure holder. Please check whether the float is
moving freely at pump operation. The pump must always be
rinsed with clean water when used in very dirty water. The
switching on and off heights can differ.
Thermal fuse/engine protection circuit-breaker
The drowned pump is equipped with an engine protection
circuit-breaker. If the engine is overheated, the engine
protection circuit-breaker will automatically switch the pump
off. Cooling time is app. 25 minutes, the pump subsequently
switches on. If the engine protection circuit-breaker switches
on, it is absolutely necessary to identify the cause and
remove it (see also the “Failure searching“). The given data
cannot be used for “family style“ repairs as it requires specific
professional knowledge. You must contact the customer
service department at any failures.
Residual risks and protective measures
Electric residual risks:
Threat Description Protective measure(s)
Direct
electric
contact
Electric shock Safety switch against FI stray
current
Indirect
electric
contact
Electric shock
through
medium
Safety switch against FI stray
current
Disposal
Instructions for disposal arise from icons placed on the
appliance or its package. The description of individual
meanings can be found in the “Marking on appliance“.
Requirements for operating staff
The operating staff must carefully read the Operating
Instructions before using the appliance.
Qualification
Apart from the detailed instructions by a professional, no
special qualification is necessary for appliance using.
Minimum age
Persons over 16 years of age can only work on the appliance.
An exception includes youngsters trained in order to reach
knowledge under supervision of the trainer during
occupational education.
Training
Using the appliance only requires corresponding training by a
professional or the Operating Instructions. No special training
is necessary.
Technical data
GS 4000
Voltage/Frequency 230 V / 50 Hz
Motor capacity P1 400 W
Maximum delivered quantity 7000 l/h
Maximum head of delivery 6 m
Maximum immersion 5 m
Hose connection 1¼’’
Protection class IPX8
Water temperature 35 °C
Granulation 30 mm
Max. suction 4,9 kg
Weight ca 94621
Transport and storage
At winter storing, it is necessary to make sure there is
no water in the appliance as the frost could damage the
appliance.
Safety instructions for first putting into operation
Attention: The pump must not run without fillings.
The user is responsible to third parties if pump (pumping
station, etc.) is used.
To be operated on connections with a safety switch
against stray current (RCD) only!
Before putting into operation, a competent electrician must
check whether electric safety devices are in place.
Electric connection to a socket.
Check the voltage. Technical data given on the type label
must correspond with electric network voltage.
If the pump is used in ponds, wells, etc. and appropriate pumping
stations, standards valid for pumps in the given country must
unconditionally be observed.
Electric pumps used outdoors (e.g. in ponds, etc.) must be
equipped with a H07RNF type rubber connecting cable,
according to DIN 57282 or DIN 57245 standards.
If the pump is in operation, neither people nor
animals can be present or plunged in the pumped
liquid (e.g. pools, cellars, etc.).
The temperature of the drained liquid must not exceed +35
°C. If an extension cable is used, it must solely be out of
10

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Gude GS4000 94621 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Gude GS4000 94621 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Pools als bijlage per email.

De handleiding is 2,48 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info