GB
Read and understand the opera-
ting instructions before using the
appliance. Abide by all the safety
measures stated in the service manual. Act responsib-
ly toward third parties.
In case of any doubts about connection and operati-
on refer please to our customer center
Specied Conditions Of Use
The pump is solely used for drainage and for pum-
ping into and out of containers in the house, garden,
farm and agriculture and only for water. Respecting
technical data and safety precautions.
Do not use this product in any other way as stated
for normal use. Not observing general regulations
in force and instructions from this manual does not
make the manufacturer liable for damages.
The pump is not suited for long-run operation
(e.g. as a circulation pump in ponds or streams).
When used in this manner, its service life is curtailed
correspondingly. In these cases, then, use a time
switch to secure sucient idle periods between
cycles of operation.
Do not leave the pump unattended while in
operation in order to prevent subsequent
damages caused by eventual malfunctions. Make
sure to disconnect the device from the grid if you
do not plan on using it.
Do not use the pump for drinking water!
The pump must not be connected to the
existing water-supply network as a pressure-
boosting device.
Technical Data
Plunge pump GS 4001 GS 8501 GS 7501 I GSX 1101 GDT 901
Art. No ..........................................................94601 .....................94602 .....................94603 .................... 94604 .....................94246
Service connection ............230V/ 50Hz .......... 230V/ 50Hz ...........230V/ 50Hz ..........230V/ 50Hz ..........230V/ 50Hz
Motor output P1 ............................400 W .....................750 W ..................... 750 W ..................1100 W .....................800 W
Max. immersion ..................................4 m ..........................7 m ..........................7 m .........................7 m ..........................7 m
Max. head of delivery .......................5 m ..........................8 m ..........................8 m ......................... 8 m .......................30 m
Max. delivered quantity ..........8000 l/h ...............13000 l/h ...............13000 l/h ..............19000 l/h .................5500 l/h
Max. suction ..................................35 mm ................... 35 mm ....................35 mm ...................35 mm ..................0,5 mm
Max. Water temperature ................35°C ........................35°C ........................ 35°C ........................35°C ........................35°C
Hose connection
......................1“-1½“ AG .............1“-1½“ AG .............1“-1½“ AG ............ 1“-1½“ AG ....................1¼“AG
Degree of protection ......................IPX8 ........................ IPX8 .........................IPX8 ........................IPX8 ........................ IPX8
Weight ............................................... 4,4 kg ..................... 5,6 kg ......................5,8 kg .....................7,4 kg .....................7,5 kg
Safety Instructions
WARNING!
Electric shock! There is a risk of an injury caused
by electric shock!
This device is not intended for use by persons (inclu-
ding children) with limited physical, sensory or mental
capabilities or without the necessary lack experience
or knowledge unless they are supervised by a person
who is responsible for their safety or were instructed
by that person in how to use the device.
Children should be supervised to ensure that they do
not play with the device. Always keep children and
unauthorised persons out of reach of the appliance.
Operation is only allowed with a safety switch against
stray current (RCD max. stray current of 30mA).
Before putting into operation, a qualied electrician
must check whether electric safety measures required
are in place. Any national regulations in this regard
must be complied with.
Electric connection to a socket.
It is necessary to make sure the connecting socket
was not near water and humidity and the plug was
protected against humidity.
Check the voltage. Technical data given on the type
label must correspond with electric network voltage.
Only use splash proof extension cables approved for
outdoor purposes.
Do not grab the feeder cable, plunge the pump, lift or
carry it while it is connected to the grid!
Check the cable and/or socket for damages before
the appliance putting into operation.
35 °C
IP X8
1001-01-2_Tauchpumpen.indd 14 08.11.12 18:06
18

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Gude GS 8501 94602 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Gude GS 8501 94602 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans als bijlage per email.

De handleiding is 5,15 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info