If there is a fault, have the pump checked by a GÜDE
servicing or by an authorised electrical engineer.
Do not expose the pump to rain and do not use it in wet or
moisture conditions.
To avoid the pump dry run, make sure that the end of the
suction hose is always in the medium to be transported.
Before every outing in operation, fill the pump with liquid up to
the spill!
When using the pump for domestic water supply, always
observe the local regulations of water management
authorities and the waste water drainage.
In addition, observe the provisions of DIN 1988.
The pump is not suitable for long-term operation (e.g.
as a circulation pump in ponds or brooks). The service life
gets shorter accordingly if the pump is used in this manner. In
such a case, use a switching clock and ensure sufficiently
long breaks between the operating cycles.
The pump must not be connected to the existing water
supply system as equipment increasing the pressure.
The pump is not suitable as a long-term, automatic
safety against overflow of tanks and wells or for control of
underground water in cellars.
Do not leave the pump unattended to prevent damage
as a result of any faulty function. Always disconnect the pump
from network if not used.
The producer does not guarantee for any damage caused by
unqualified installation or unprofessional operation of the
pump.
The equipment must be regularly inspected and its faultless
condition needs to be checked.
Before each putting into operation, the pump must be visually
inspected for any damage (especially on the power supply
cable and plug). Using a damaged pump is strictly prohibited.
Emergency Action
Take the measures of first aid according the kind of injury and
get a qualified medical aid fast..
Protect the injured person before another detriment and calm
him/her down.
Assigned Use
The pump is designed for pumping clean water only to supply
the home with water and to use it at home, in garden,
courtyard and for fields. The manufacturer should not be held
liable for non-observance of the general regulations and
provisions in this manual.
Residua Hazards and Protective Action
Electrical Residua Hazards
Hazard Description Protective Action
Direct
electrical
contact
Electrical shock Stray current switch FI
Indirect
electrical
contact
Electrical shock
by medium
Stray current switch FI
Disposal
Waste disposal instructions according to the picturegraphs on
unit or on packaging . Meaning of the symbols to be found in
Chapter “Symbols on Unit”.
Operator Requirement
The operator shall read the instruction manual carefully
before using the unit.
Qualification
No special qualification is required for use of the unit except
for detailed direction by a professional.
Minimum Age
Only persons above 16 years of age are allowed to work with
the unit.
Exempted from the provision is the use of the juvenile
trainees if they work in the course of their professional
training with an aim to obtain the skill under trainer
supervision.
Training
Use of the unit requires adequate lesson by a professional or
the use of the manual only. Special training is not required.
Technical Data
Connection 230 V~50 Hz
Motor output P1 1100 W (P1)
Max. suction head 8 m
Max. pumped quantity 4600 l/h
Max. pumping height 45 m
Suction connection 1’’ IG
Protection type IP X4
Water temperature 35 °C
Approximate weight 9 kg
Product number 94209
Transportation and Storage
No water should be left in the unit when stored in
winter because the unit would get impaired by effect of frost.
For any transportation, the pump shall be disconnected from
the mains!
Initial Operation Safety Instructions
Caution: The pump should not run dry.
Do not use the pump for drinking water pumping!
Regarding the use of the pump (water facilities etc.) the user
shall be liable before third persons. Operate on connections
with the stray current switch (FI-switch)!
Before putting the unit in operation, a competent electrician
should check whether required safety measures are available.
A socket should be used for electrical connection.
The voltage should be checked. Technical data on the plate
should coincide with the voltage in the system.
If the pump is used in ponds, wells etc. and in other water
management facilities it is essential to observe, the standards
effective in the countries, in which the pump is operated.
Electrical pumps for works outdoors should be equipped with an
electrical cable of rubber, type H07RNF, as required by
standards DIN 57282 or DIN 57245.
If the pump is in operation, persons or animals should
not be allowed to stay or to soak in the liquid to be
transferred (e.g. pools, cellars etc.).
Temperature of the liquid to be pumped out should not be in
excess of +35°C. The extension cables shall be of rubber
type H07RNF only, as required by standards DIN 57282 or
DIN 57245. Never touch the cable of electrically connected
pump, do not lift or push it by the cable. Remember that the
socket should be at a safe distance from water and moisture
so that the plug is protected against moisture.
10
10

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Gude GP 4600 VF bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Gude GP 4600 VF in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans als bijlage per email.

De handleiding is 0,66 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info