628577
14
Verklein
Vergroot
Pagina terug
1/62
Pagina verder
Please, observe local requirements applicable to disposal of
used oil.
If the engine operates, do not pour engine oil in it.
Before filling of the engine oil, turn the pump off and let it
cool down for at least 5 minutes. During pouring of the
engine oil, the machine must be placed on a flat surface in
vertical position to avoid engine oil leak. All leaked engine
oil must be first cleaned and then start up the engine.
Do not smoke and work with open flame when
pouring the engine oil. Do not breathe vapours.
Automatic Auto Stop activation (safety feature for low
oil level) for low oil level.
This technology automatically turns the engine off when the
oil level is lower than minimum required. The engine can be
restarted after sufficient quantity of engine oil is
replenished. When replenishing engine oil, adhere to all
instructions related to the engine oil and engine oil check as
specified in this guide.
Ignition plug
Cleaning of the ignition plug and correction of distances of
the electrodes must be performed in six-month intervals or
after 100 hours of operation. First, remove the ignition plug
shield before maintenance of the ignition plug. Then, screw
the ignition plug out using the ignition plug key. To ensure
failure-free operation, the dry ignition plug without burnt
residues must show distance of the electrodes 0.6 - 0.7
mm.
If necessary, clean the ignition plug. To remove the burnt
residues, use a fine wire brush. Distance of the electrodes
must be corrected by slight bending of the electrode. It is
recommended to use a new ignition plug in case of strong
accumulation or worn electrodes.
Checked, cleaned or a new ignition plug must be screwed
first manually to stop. Then, tighten the ignition plug using
the ignition plug key. Avoid excessive forces not to damage
the ignition plug due to torque. Finally, slide the ignition plug
shield back on the ignition plug.
Air filter
To clean the air filter, do not use gasoline or a
thinner with low flash point in any case due to fire and
explosion danger.
If the air filter is clogged, it prevents air flow to the
carburettor. To avoid operation failures of the carburettor,
air filter must be regularly checked and cleaned or replaced,
if necessary.
Generally, checking of the air filter as far as clogging is
concerned is recommended before use. Cleaning is
required in three-month interval or after 50 hours of
operation. When the pump is operated in dirty or dusty
environment, cleaning must be performed in ten-hour
intervals. Use a new air filter in six-month interval or after
300 hours of operation.
Open air filter cabinet and remove the air filter before
maintenance. Wash the air filter with an inflammable
thinner, if necessary - e.g. detergent. To clean the air filter,
do not use gasoline or a thinner with low flash point in any
case due to fire and explosion danger. Let the air filter dry
after cleaning.
Insert checked, cleaned or new air filter and close it again.
Do never use the pump without the air filter to avoid
increased wear and tear of the engine.
Replacement of the slide locking ring
The slide locking ring is the seal between the pump body and
the engine shaft. The ring is a component with natural wear and
tear.
If the slide locking ring is defective, water leaks between the
engine and the pump body. Demount the pump body, manual
starting device and the pump moving wheel. Then, the slide
locking ring may be replaced. Finally, carefully mount the
moving wheel of the pump, manual starting device and the
pump body.
Removal of foreign particles from the pump
Coarser particles in the pumped liquid may block the pump
body and the pump moving wheel. For this case, the pump
body can be demounted in order to remove all impurities from
the pump moving wheel.
Storing
If the machine is not used for longer time, all water in the pump
must be drained. Let the pump dry to avoid corrosion. Drain the
fuel tank and the carburettor. Cleaning and preserving of the
machine before storing is recommended. Make sure the
machine is stored in dry and frost-proof place.
Failures
Make sure no water gets in the machine.
We shall not be liable for damage due to unprofessional
repair attempts. Damage due to unprofessional repair attempts
shall void any warranty claims.
All measures for removal of defects may be performed only if
the engine is stopped.
The following list specifies some potential machine damages,
potential reasons and tips for removal. All measures for removal
of defects may be performed only if the engine is stopped. If
you are unable to remedy the defect, please contact either the
customer service or your sales representative. Overhaul repairs
may be performed by authorized personnel only. Please note
that warranty claims shall void in case of damage due to
unprofessional repair attempts and we shall not be responsible
for any consequent damage.
In case of operation failures, first check for operator error or
other cause not associated with the machine defect - e.g. no
fuel.
Maintenance table
Defect Possible cause Remedy
The pump
does not
pump or
pumps too
little of liquid,
the engine
runs.
1. Too much liquid in
the pump.
2. Suction piping not
sealing.
3. Too low engine
power selected.
4. Suction piping
input filter clogged.
5. Suction piping
clogged.
6. Pump moving
wheel blocked by
impurities.
7. Too high suction
lift/total head.
8. Defective slide
locking ring.
9. Pump moving
wheel not fitted
correctly.
10. Damaged pump
moving wheel.
11. Irregular engine
operation.
1. Pour liquid in the
filling hole of the
pump body.
2. Tighten the
suction piping
and piping
connectors with
Teflon tape.
Replace the
suction piping if
irreparable
damage is
detected.
3. Increase engine
power.
4. Clean the filter.
5. Clean the suction
piping.
6. Remove
impurities.
7. Change the
installation so that
the suction
lift/total head
does not exceed
maximum value.
8. Replace the slide
locking ring.
14
14

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Gude GMP 100 4T 94253 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Gude GMP 100 4T 94253 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans als bijlage per email.

De handleiding is 1,78 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info