Appliance-specific safety instructions
WARNINGS
IMPORTANT: Please read carefully the complete
Operating Instructions before assembling, handling
and maintaining this heating unit. Any unauthorised
use of this heating unit may result in serious injuries
or death as a result of burn, fire, explosion, electric
shock and carbon monoxide poisoning.
! CAUTION: Carbon monoxide poisoning may be fatal!
Carbon monoxide poisoning: Early symptoms of carbon
monoxide poisoning are similar to those experienced at flu,
i.e. headache, giddiness and/or indisposition. If such
symptoms are experienced, it may be possible your
heating body is not working properly. Get out
immediately! Have your heating unit inspected. Some
persons are more sensitive to carbon monoxide than other
ones, e.g. pregnant women, persons with cardiac or
pulmonary diseases or anaemia, persons under the
influence of alcohol and persons at heights. Make sure you
have read all the maintenance instructions and have
understood them. Keep these Operating Instructions for
future reference. They are your guide for safe and
professional handling of this heating unit.
Use only oil to prevent fire and risk of explosion. Petrol,
crude oil, paint thinners, alcohol and other highly
flammable fuels must not be used in any case.
Fuel:
a) Staff providing refuelling must be trained and fully
familiarised with the manufacturer's instructions and
applicable directives for safe refuelling of heating
units.
b) Only oil may be used for refuelling.
c) Any flame including the pilot flame must be blown out
to allow the heating unit to cool down before
refuelling.
d) Fuel lines and connections must be checked for
leaking when refuelling takes place. Any leaking must
be repaired before putting the heating unit back into
operation.
e) The maximum fuel daily dose should only be stored
in buildings near the heating unit. Large fuel reserves
to be stored outside the building.
f) All fuel storages must be at least 762 cm from
heating units, burners, welders and similar
inflammable sources (exception being a fuel tank
integrated in the heating unit).
g) If applicable, fuel storage should only be limited to
spaces where the flooring design prevents leaked
fuel accumulation and the fuel cannot catch fire as a
result of deeply stored inflammable sources.
h) Fuel must be stored in accordance with the local
official regulations.
General information:
Never use the heating unit near petrol, paint thinners
or other easily combustible fumes.
Follow all local provisions and regulations when using
this heating unit.
Heating units used near reinforcement grids,
canvases or other coverings must be placed in a safe
distance from these materials. The recommended
minimum distance is 305 cm. Moreover, using
fireproof coverings is recommended. Fireproof
coverings must be safely attached to be protected
against catching fire and prevent heating unit being
touched and turned over due to wind gust.
To be used in well ventilated spaces only. Before
putting the appliance into operation, make sure air
vent of at least 2,800 cm² for fresh external air is
provided for heating output of 100,000 BTU per hour.
To be used in spaces with no flammable vapours or
high dust levels only.
To be used at voltage and frequency specified on the
type label only.
A properly earthed extension cable to be used at all
times.
Minimum distance from flammable materials and
persons:
exhaust: 300 cm at sides, upper and rear side: 200
cm. (see pic. D)
To prevent a risk of fire, the hot heating unit or
heating unit just being operated must be placed on a
safe and level surface.
The heating unit must be transferred or stored in a
horizontal position to prevent fuel leaking.
Keep children and pets in a sufficient distance from
the heating unit.
Unplug the heating unit if not being operated.
Never use the heating unit in residential rooms and
sleeping rooms.
Never block the air inlet (rear side) and air outlet
(front side) of the heating unit.
If the heating unit is hot, being operated or plugged, it
must never be transferred, handled, refuelled or
maintained.
Do not fit any piping on the front and rear side of the
heating unit.
CAUTION:
Oil to be used only to prevent fire or explosion.
Using the appliance as a heat source for events
and parties or operating the appliance in stables is
strictly prohibited!
Use as designated
The GD-series oil hot-air turbine must solely be used for
heating and drying purposes in well ventilated spaces or
dry outdoor zones, in a safe distance from flammable
materials and other animals. It must be placed on a stable
and level surface when being operated. Only oil is allowed
to be used for refuelling.
(As far as safety, functionality and service life are
concerned, the GD series follows the latest criteria: the
safety equipment guarantees appropriate working of the
appliance; operating noise have been reduced to minimum
levels and the careful material selection makes it as much
reliable as possible.)
Assembly, pic. B
Description, pic. B
1. Frame
2. Screw
3. Washer
4. Wheel cover
5. Wheel
6. Case
7. Axis
These models are supplied with wheels and handles.
Wheels, handles and appropriate parts for attaching are in
the box.
12
12

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Gude GD 50 IK 85111 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Gude GD 50 IK 85111 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans als bijlage per email.

De handleiding is 1,9 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info