467066
17
Verklein
Vergroot
Pagina terug
1/36
Pagina verder
3130
17. Error messages and warnings
The ULTRAMAT 12 incorporates a wide range of protective and monitoring systems designed to
check the charger’s functions and monitor the state of its electronics. If any of the unit’s limit
values are exceeded, the charger responds accordingly: in some cases the unit’s settings are
automatically reduced (e.g. charge current / discharge current); in others the charge process is
switched off (e.g. car battery almost flat).
The liquid crystal screen displays the cause of the error. Most error messages are self-
explanatory, but you may find the following list useful when fault-finding. The warning message
and the audible warning signal can be switched off by pressing the „ENTER“ button.
___________ _____
___________ _____
*****ERROR******
car batt. empty
This warning message is displayed if the voltage of the car
battery falls
below the value set in the „Low voltage cut-
off“ section of the user settings (11.0 V).
If the charger detects an interruption of the connection
between battery and charger during a charge process, the
screen displays this error message. If you see this error
message when the charger is in use, it may indicate an
intermittent contact.
Note: the same error message also appears if you
deliberately interrupt the charge process, e.g. by discon-
necting the charge lead.
If the internal charge safety timer has elapsed, the current
process is terminated for safety’s sake. The safety timer is
set permanently to 180 minutes for Ni-Cd / Ni-MH batt-
eries. For Lithium batteries the set period is 180 minutes.
The timer is disabled when a lead-acid battery is being
charged. These settings are fixed, and cannot be altered.
Possible causes: charge current too low: battery cannot be
fully charged; charge leads too thin and / or too long -
charge current cannot rise high enough: battery capacity
too high.
If the charger detects an excessive voltage, e.g. incorrect
setting of the cell count with a Lithium or lead-acid battery,
this error message is displayed.
The same error message may also appear if the cells
connected to the charger are overcharged.
If the charger detects too low a voltage, e.g. incorrect
setting of the cell count with a Lithium or lead-acid battery,
this error message is displayed.
The purpose of this error message is to avoid the cells
becoming deep-discharged due to an incorrect setting.
This warning message is displayed if a battery is
connected to the unit’s charge outputs with incorrect
polarity.
When a charge or discharge program comes to an end,
the screen displays the message END, alternating with
the program name. At the same time the integral buzzer
sounds for a limited period, unless you have already
disabled it in the „Button click / buzzer“ user settings
section.
Ready message
The current input voltage can be called up at any time by
pressing the INC and DEC buttons
simultaneously
This can be very useful if you are using your car’s battery
as energy source for charging
Press any button to return to the menu system.
15. Screen displays
Battery voltage
________________
________________
CHG 12:56 00321
NC+4.50A 11,985V
Program Charge / discharge time
Charge / discharge current
Capacity
The two-line liquid-crystal screen displays in a clear form the important information generated
during the charge / discharge process. The information remains visible on-screen until you
disconnect the battery that is being charged. Once you connect another battery for charging, the
previously displayed values are erased, and cannot be called up again.
16. On-screen monitor displays
The ULTRAMAT 12 incorporates a wide range of protective and monitoring systems designed to
check the charger’s functions and monitor the state of its electronics. If any of the unit’s critical
limit values is exceeded, the charge process is switched off. Typical triggers would be excessive
voltage, excessive temperature or a depleted car battery.
If any of these problems should occur, the liquid crystal screen displays the cause of the error,
and the buzzer sounds to alert you.
___________ _____
___________ _____
BATTERY CHECK
WAIT PLEASE...
Measuring process
When you hold the START button pressed in for about two
seconds, the charger measures the battery connected to
it. This message appears on the screen for one or two
seconds before the charge process is initiated.
Battery type
___________ _____
___________ _____
Input Voltage
13,62V
DECINC
___________ _____
___________ _____
CHG 48:32 03363
NC 200mA 9.773V
END
Input voltage display
___________ _____
___________ _____
*****ERROR******
wrong polarity
___________ _____
___________ _____
*****ERROR******
contact break
___________ _____
___________ _____
*****ERROR******
time limit over
___________ _____
___________ _____
*****ERROR******
bat.volt too hi.
___________ _____
___________ _____
*****ERROR******
bat.volt too low
17

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Graupner Ultramat 12 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Graupner Ultramat 12 in de taal/talen: Duits, Engels, Frans als bijlage per email.

De handleiding is 0,71 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Graupner Ultramat 12

Graupner Ultramat 12 Gebruiksaanwijzing - Nederlands - 14 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info