590653
2
Verklein
Vergroot
Pagina terug
1/8
Pagina verder
2 GMC-I Messtechnik GmbH
Table of Contents
Page
1 Introduction ...................................................................... 2
1.1 Scope of Delivery ...........................................................................2
1.2 Optional Accessories ......................................................................2
1.3 Safety Precautions .........................................................................2
1.4 Applications ..................................................................................3
1.5 Applicable Standards .....................................................................3
1.6 Environment ..................................................................................3
2 Device Description ........................................................... 3
2.1 Housing ........................................................................................3
2.2 Control Panel .................................................................................3
2.3 Initial Start-Up ...............................................................................3
3 Performing Measurements .............................................. 4
3.1 Switching the Instrument On and Off, Energy-Saving Mode,
Automatic Shutdown ......................................................................4
3.2 Instructions and Principles with Validity for
All Measurements ..........................................................................4
3.3 Measuring Functions ......................................................................4
3.3.1 Voltage Measurement ....................................................................4
3.3.2 Insulation Resistance Measurement ................................................5
3.3.3 Measurements at Varistors (surge protection devices) ......................5
3.4 Further Device Functions ................................................................6
3.5 Device Reset Function ....................................................................7
4 Technical Data ................................................................. 7
4.1 Measuring Functions ......................................................................7
4.2 General Data .................................................................................7
5 Maintenance .................................................................... 7
5.1 Device Power Supply .....................................................................7
5.1.1 Inserting and Replacing the Batteries ..............................................7
5.1.2 Recharging the Batteries ................................................................8
5.2 Cleaning .......................................................................................8
5.3 Recalibration .................................................................................8
6 Repair and Replacement Parts Service,
Calibration Center and Rental
Instrument Service ........................................................... 8
7 Product Support ............................................................... 8
1 Introduction
1.1 Scope of Delivery
1 Test instrument with mobile test probe
4 Batteries (AAA)
1Pouch
1 Condensed operating instructions
1
CD ROM with operating instructions in available languages
1 Factory calibration certificate
1.2 Optional Accessories
4 ea. rechargeable AAA NiMH batteries (Z507B)
1 battery charger (Z507A)
1.3 Safety Precautions
Read the operating instructions thoroughly and carefully before
using your instrument. Follow all instructions contained therein.
Make sure that the operating instructions are available to all users
of the instrument.
Meanings of Symbols on the Instrument
This device is equipped with double or reinforced insula-
tion.
Danger of injury due to electrical current,
warning regarding dangerous electrical voltage
Warning concerning a source of danger
(attention, observe documentation!)
EC mark of conformity: This instrument fulfills all
requirements of applicable European directives.
Before using the instrument, it must be assured that it is safe. Do
not use if:
Visible damage is apparent
The battery compartment lid is missing
The device has been stored under unfavorable conditions for
a lengthy period of time
The device has been handled impermissibly, e.g. has been
dropped from a height of 1 meter or more
The test instrument does not function as described in these
operating instructions (if this is the case, we recommend
resetting the device as described in section 3.5 on page 7)
CAUTION
Do not touch electrically conductive parts, test probes etc.
when the device is switched on and voltage might still be con-
ducted by a test probe – DANGER OF INJURY!
Only use test probes which are included with the instrument
or are available as accessories.
The device must be switched off and no voltage may be
applied when exchanging accessories.
It is absolutely essential to adhere to all safety precautions,
regulations and standards when performing measurements.
No keys may be pressed when connecting the instrument to a
device under test.
The test instrument may not be subjected to the influence of
aggressive substances, gases, vapors, liquids or dust.
The test instrument may only be used under the conditions
listed in the technical data in section 5 on page 7.
If the device is moved from a colder to a warmer room, con-
densation may occur, in which case a brief period of acclima-
tization is advisable.
We recommend removing the batteries during lengths periods
of storage.
Two relatively strong magnets are integrated into the test
instrument. Avoid close proximity to magnetically sensitive
objects such as watches, credit cards and the like.
The illustrations in these operating instructions are drawings
and may therefore deviate from reality.
Use original accessories only.
Maximum permissible voltage between test probe and ground
is 300 V!
Maximum permissible (externally applied) voltage between the
test probes is 600 V!
Opening of Equipment / Repair
The equipment may be opened only by authorized service per-
sonnel to ensure the safe and correct operation of the equipment
and to keep the warranty valid.
Even original spare parts may be installed only by authorized ser-
vice personnel.
In case the equipment was opened by unauthorized personnel,
no warranty regarding personal safety, measurement accuracy,
conformity with applicable safety measures or any consequential
damage is granted by the manufacturer.
!
!
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Gossen Metrawatt METRALINE ISO-CHECK bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Gossen Metrawatt METRALINE ISO-CHECK in de taal/talen: Engels als bijlage per email.

De handleiding is 0,39 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Gossen Metrawatt METRALINE ISO-CHECK

Gossen Metrawatt METRALINE ISO-CHECK Gebruiksaanwijzing - Nederlands - 8 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info