650414
44
Verklein
Vergroot
Pagina terug
1/52
Pagina verder
P
lus Nexa
Cód. 50121552
Instructions manua
l
Audio and Video
door entry system
(One or several
accesses doors /
General door panel)
T631/PLUS ML rev.0112
105
INTRODUCTION
STARTING RECOMMENDATIONS
INDEX
First of all we would like to thank and congratulate you for the purchase of this product manufactured by
Golmar.
The commitment to reach the satisfaction of our customers is stated through the ISO-9001 certification
and for the manufacturing of products like this one.
Its advanced technology and exacting quality control will do that customers and users enjoy with the
legion of features this system offers. To obtain the maximum profit of these features and a properly wired
installation, we kindly recommend you to expend a few minutes of your time to read this manual.
O
O
O
O
O
Do not use excessive force when tightening the power supply connector screws.
The entire installation must be at least 40cm. away from any other installation.
Before to connect the system, check the connections between door panel, monitors, telephones, and
the transformer connection. Do always follow the enclosed information.
Each time the power supply is restarted, or after a modification, the system will remain blocked during
30 seconds.
Always use RG-59 B/U MIL C-17 or RG-11 coaxial cables, (see page 138). Never use coaxial
antenna cable. In installations no longers than 100m., Golmar RAP-5130cablecanbeused.
Introduction .........................................105
Index...................................................105
Starting recommendations .....................105
Safety precautions.................................106
System characteristics.....................106-107
System operation ..................................107
Door panel description ..........................108
Modules description....................................
Sound moduleEL631Plus / EL640 Plus...109
Push buttons module EL610D...............110
Door panel ................................................
.................111
Embedding box installation ..........111-112
Assembly electronic modules ...............112
Hold the Frame ..................................113
Push buttons connection...............113-114
Push buttons coding............................114
Sound module configuration ........115-116
Programming (general panel) .......117-119
Function connector Cn5 description......119
Final adjustments ...............................120
Place the nameplate labels ..................120
Door panel assembly ..........................121
Close the door panel...........................121
Powersupplyinstallation........................122
Lockrelease installation.........................122
Platea Plus / TeknaPlus monitor ....................
Description........................................123
Embedding box positioning
Function push buttons .........................124
El562 module....................................125
End of line resistor...............................125
Frontfilm replacement ........................125
Monitor connector description .............126
Monitor installation.............................127
Programming.....................................128
T-940 Plus telephone...................................
Description........................................129
Function push buttons .........................129
Telephoneinstallation .........................130
Programming.....................................131
T-740 Plus telephone...................................
Description.................................132-133
Function push buttons .........................133
Telephoneinstallation .........................134
Programming.....................................135
Installation diagrams...................................
Connection of an a.c. lock release........136
Link of several power supplies...............136
Video installation with coaxial .......137-138
Video installation without coaxial...139-140
Audio installation ........................141-142
Video installtion (general panel) ....143-146
Audio installation (general panel)..147-148
Optional connections ....................149-153
Troubleshootinghints ............................154
Compliance.........................................155
106
SAFETY PRECAUTIONS
SYSTEM CHARACTERISTICS
O Audio and video door entry system with simplified installation:
wAudio door entry system with 4 common wires installation.
wVideo door entry system with 3 common wires plus coaxial cable installation.
wVideo door entry system with 4 common wires plus twisted pair installation.
O Soundmodulewith twooperatingmodes(EL500orEL501).
O Unlimited number of door panels (access) being not necessary the use of switching units.
O Upto120monitors/telephonesper installationorbackbone.
O General door panel(EL501 mode): Up to 120 monitors/telephones, distributed in max. 120 buildings.
O EL560modulefor videoinstallationswithtwistedpaircable,integratedin soundmodule.
O Communicationsresistorforthe systemUNO or PLUS, integratedinsoundmodule.
O Acoustic busy channel and call acknowledgement signals.
O Door opening timed at 3 seconds.
O Input for external door release push button (timed at 3 or 15 seconds).
O a.c or d.c lock release operated by relay.
O Up to three monitors or telephones in the same apartment without additional power supplies.
O WithT-940 Plus telephones:
wPrivacy on audio communications.
wThree-position control for call volume: maximum, medium and minimum.
wIntercommunication function with other monitor or telephone of the same apartment.
wInput for external door bell push button.
wOutput for additional call repeater.
wCall to a master porter's exchange.
wPanic call to the porter's exchange.
wDifferent call reception tones depending where the call is comming from: main or slave door
panels, door bell push button, intercom, ...
O WithT-740 Plus telephones, addition to the above features:
wThree-position control for call volume: maximum, medium and off.
wInput for external door release push button.
Continue
O
O
O
O
w
w
w
w
w
O
w
w
w
O
O
Install or modify the equipment without the power connected.
The installation and handling of these equipments must be performed by authorised personnel.
The entire installation must be at least 40 cm. away from any other installation.
Withpower supply:
wDo not use excessive force when tightening the connector screws.
Install the power supply in a dry and protected place without risk of drip or water projections.
Avoid to place it near to heating sources, in dusty locations or smoky enviroments.
Do not block ventilation holes of the unit so that air can circulate freely.
Toavoid damage, the power supply has to be firmly fixed.
To avoid an electrical shock, neither remove the protection cover nor handle the connected wire in
the terminals.
Withmonitor, telephones and distributor:
Do not use excessive force when tightening the connector screws.
Install the equipments in a dry and protected place without risk of drip or water projections.
Avoid to place it near to heating sources, in dusty locations or smoky enviroments.
wDo not block ventilation holes of the equipments so that air can circulate freely.
Remember, the installation and handling of these equipments must be performed by authorized
personnel and in the absence of electrical current.
Do always follow the enclosed information.
107
SYSTEM OPERATION
O To make a call the visitor should press the push button corresponding to the apartment he wishes to
contact. An acoustic tone will be heard confirming the call is in progress once the push button has
been pressed. At this moment the call will be received at the monitor (telephone) in the dwelling.
During the call the visitor can correct his call by pressing a push button corresponding to a different
apartment, in which case the original call is cancelled.
O In systems with several accesses doors, the other(s) door panel(s) will be automatically disconnected:
If a visitor tries to call from other door panel an acoustic tone will be heard confirming the system is
busy and the led of busy system from informative window will lights (If it exists).
O General door panel (EL501 mode): If the call is made from the general door panel, the inner door
panel of the building called and other possible general door panel will remain automatically
disconnected, if another visitor tries to call from an inner busy door panel or from another general
door panel, an acoustic tone will be heard confirming the system is busy and the led of system busy
will blink (in the general door panel). The door panels of the others inner buildings will remain free to
be used.
O General door panel (EL501mode): In the case thatthe call is made froman inner door panel, therest
of inner door panels will remain free to be used. From general door panels only will be able to make
calls to the inner buildings whose door panels are not in use, if the visitor tries to make a call to a busy
inner door panel, an acoustic tone will be heard confirming the system is busy and the led of system
busy from informative window will blink.
O The call tone will be reproduced on the monitor during 3 seconds: after this time the picture will
appear on the master monitor without the visitor being aware of this. To see the picture in a slave
monitor press the push button, dissapearing the picture on the other monitor. If the call is not
answered in 45 seconds, the system will be freed.
O Toestablish communication pick up the monitor (telephone) handset.
O The communication will last for one and a half minutes or until the handset is replaced. Once the
communication has finished the system will be freed.
O To open the door, press the door release push button during call or communication progresses: with
one press, the door release operates during 3seconds. During the lockrelease activation an acoustic
tone will be heard on the door panel confirming the lock release is activated.
O Themonitorandtelephonespushbuttonsdescriptionis shownonpages124,129& 133 respectively.
SYSTEM CHARACTERISTICS
wAllows one of these functions at once, Configuration with dip switch Sw1 (see page 133):
w"Autoswitch-on" function.
wOutput for auxiliary relay activation (18Vdc/0,5 A maximum).
wCall to a slave porter's exchange.
wIntercommunication function with other monitor or telephone of the same apartment.
OWithPlatea Plus / TeknaPlusmonitors,additiontotheT-940 Plus telephones features:
w"Autoswitch-on" function.
w"Video-spy" function with the communication channel remaining free.
wCall to a slave porter's exchange.
wActivation of two auxiliary devices: secondary telecamera, courtesy light, ...
wB/W & Color monitor.
wBrightness and contrast control (color control in case of color screen).
Coming from previous page
108
DOOR PANEL DESCRIPTION
Sound module
EL631 Plus
EL640 Plus
oor panel description.
D
Push buttons electronic module
EL610D
Short connection cable, It is supplied with EL610D module (16 cm length).
, for 5 single push-buttons or 10 double push buttons.
, on video systems with color camera.
, on audio systems.
Connection cable RAP-610D (27 cm length).
General detail of parts, for assembly the door panel.
Aluminium modules
Electronic
modules
Frame modulesEmbedding boxes
Push buttons module
Main module
Door panel description.
For the connection of the push-buttons between the sound module and the push
buttons module EL610D and between push-buttons modules EL610D.
For the connection of the push-buttons between the sound module and the push
buttons module EL610D and between push-buttons modules EL610D.
This cable is necessary when the distance between modules to connecting is
greater due to the distribution of these modules in the door panel/s.
109
ound module description.
s
Microphone.
Speaker.
Door panel audio adjustment.
Monitor audio adjustment.
Front side.
Sound module push buttons (x2).
Installation terminals CN2 (Plus Nexa Bus).
Label.
Push buttons connector CN9.
Back side.
:
: "N.O" contact free for lock release.
: Positive, ground.
: Digital communication.
: Audio output communication.
: Audio input communication.
: Twisted pair video signal input.
: Twisted pair video signal output.
: Coaxial shield.
: Video signal coaxial input.
: Video signal coaxial output.
"C" contact free for lock release.
Configuration dip switch SW1.
Push button number.
Color camera (only EL631 Plus sound module).
CV1
CV2
+,
D
Aout
Ain
Vi+,Vi-
Vo+,Vo-
Malla
Vi+
Vo+
_
Installation terminals:
Note: See installation diagrams for wiring.
MODULES DESCRIPTION
CV2CV1
_
_
+
+
Ai
V
i
-
V
i +
VO
-
VO+
D
Ao
Malla
Configuration dip switch SW2.
Function connector Cn5.
110
ush buttons electronic module EL610D description.
P
Front side.
Push buttons module (x10).
Configuration dip switch
(Push buttons call code).
Push button number.
Input/Output push buttons connector (x3).
Back side.
MODULES DESCRIPTION
90CS
CEA90C
99
143
40
Door panel
Model
An
Al
P
90C
CEV90C
99
250
56
90
CEV90
99 mm.
328 mm.
56 mm.
1650
1850
1450
111
DOOR PANEL INSTALLATION
mbedding box positioning.
E
The upper part of the door panel should be placed at 1,65m. height roughly. The hole dimensions
will depend on the type of door panel.
The door panel has been designed to be placed under most of the environmental conditions.
However it's recommended to take additional cautions like rainproof covers. To obtain a good
quality picture on video door entry systems, avoid direct incidence from light sources.
reparing the cables entry.
P
Break the bottom flange to pass the cables through. In case of door panels
with more than one embedding box, break the side flanges and
attach the embedding boxes using UC junctions.
ssembly the electronic modules.
A
Insert the sound module in the top part of the module frame.
Align the tabs on the sound module in their respective housings of the module frame and
later exercise a light pressure until correct placement.
Sound module
EL631 Plus
EL640 Plus
Push buttons electronic
module EL610D
Frame
If there is push buttons module repeat the above process, locating under the sound module,
as shown in the drawing.
Frame
112
DOOR PANEL INSTALLATION
lace the embedding box.
P
Pass thewiringthrough the hole made in thebottompart of the
embedding box. Level and flush the embedding box. Once
the embedding box is placed, remove the protective labels
from the attaching door panel holes.
113
DOOR PANEL INSTALLATION
old the frame on the embedding box.
H
lug the push buttons with the short
P
connection cable.
Between push buttons modules EL610D of the same embedding box,
insert the short connection cable of the low connector of the first push
buttons module to the top connector of the second push buttons
module, as shown in the drawing.
Insert the short connection cable that it is supplied with the product
EL610D, in the push buttons connector of the sound module and the
other end of the connection cable in the connector placed in the top
part of the push buttons EL610D module, as shown in the drawing.
Between push buttons modules EL610D of different embeddingt boxes,
insert the short connection cable in the low connector of the last
module EL610D of the first embedding box and the other end of the
connection cable in the middle connector of the last push buttons
module EL610D placed in the low part of the second embedding box,
as shown in the drawing.
Insert the hinge that it is supplied with the product in the embedding
box, as shown in the drawing.
To hold the frame on the embedding box, insert the hinge in the
housings arranged for this purpose in the frame, as shown in
the drawing.
The frame can now be folded horizontally facilitating the connection
and adjustments in the sound module and push buttons electronic
module.
114
DOOR PANEL INSTALLATION
lug the push buttons with the connection
P
cable RAP-610D.
onfiguration of the push-buttons code.
C
Push buttons module EL-610D
2
Dip1
1
4
6
8
3
5
7
71
Dip2
Dip3
Dip4
Dip5
Dip6
Dip7
Dip8
Push buttons code
Module configuration option
P1 P2 P3 P4 P5 P6 P7
1
21
41
61
11
31
51
2
22
42
62
12
32
52
72
3
23
43
63
13
33
53
73
4
24
44
64
14
34
54
74
5
25
45
65
15
35
55
75
6
26
46
66
16
36
56
76
7
27
47
67
17
37
57
77
8
28
48
68
18
38
58
78
9
29
49
69
19
39
59
79
10
30
50
70
20
40
60
80
P8 P9 P10
10
12
9
11
13
81
101
122
91
112
82
102
123
92
113
83
103
124
93
114
84
104
125
94
115
85
105
126
95
116
86
107
127
96
117
87
108
128
97
118
88
109
129
98
119
89
110
130
99
120
90
111
131
100
121
Dip switch
On
On
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
On
Off
Off
Off
Off
On
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
On
Off
Off
Off
Off
On
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
On
Off
Off
Off
Off
On
Off
Off
Off
Off
On
On
On
On
On
On
On
Off
Off
Off
Off
Off
On
Off
Off
Off
Off
Off
Off
Off
On
Off
Off
On
Off
Off
Off
Off
Off
Off
Off
On
Off
Off
On
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Important: Select a different configuration option for each module EL610D.
P1- P10: Push button 1 to push button 10.
*
( )
*
( )
Note:Sound module, factory set the code "106" in P1 and "132" in P2.
Use the connection cable RAP-610D, for the connection of the push buttons
between the sound module and the push buttons module EL610D and
between push buttons modules EL610D, when the distance between
modules to connecting is greater due to the composition of the door panels.
The push buttons module EL610D must be configured, to assign a call code to
the push buttons (use the tool that is supplied with the sound module). Make
this configuration with the dip switch placed in the back side of the module.
Depending on the setting selected, the push buttons are assigned to a specific
call code.
In case to combine these door panels with coded door panels or porter
's
exchange, it will be necessary to known the call code of each push button, as
shown in the table below.
115
escription of the SW1 configuration dip-switch of
D
the sound module.
Placed to OFF if the EL631/Plus module is configured as EL500
.
Set to ON if the EL631/Plus module is configured as EL501
(general door panel).
operating
mode
operating mode
Selects the d done from the ('AP'
terminal), see page 149.
Placed to ON: door opening timed at 3 seconds.
Set to OFF:dooropeningtimedat15seconds.
oor opening time, external push button
Selects the type of cable to be used for the video signal.
Placed to OFF:coaxialcableRG-59 o RG-11.
Set to ON: twisted pair.
Placed to OFF if the door panel has telecamera. In case of door panels
without telecamera (EL640 Plus sound module) set to ON.
Plus system, loads the installation with a communications resistor Plus. For a
proper system operation, placed to ON only in the closest door panel to the
backbone installation or in the general door panel (if exists), set the rest to
OFF.
Set to ON so that the volume tone emitted by the door panel:
(call reception, busy system and lock release) are HIGH, or placed to OFF if a
LOW volume tone is desired.
Uno System,
proper system operation, set to ON only in the closest door panel to the
backbone installation, placed the rest to OFF.
Withdigital repeater RD Plus/Uno:
In the backbone installation or after the inner door panel in systems with
general door panels, placed the door panel/s to OFF.
loads the installation with a communications resistor Uno. Fora
6
6
7
6
7
6
Placed to ON,
porter's exchange (if exists).Set to OFF, the call is received in the apartment.
In general door panels systems with porter's exchange, this function is only
applicable to the general door panels not to the inner door panel/s.
the calls made on the door panel will be transferred to the
Factory default
6
7
8
6
7
8
The SW1 configuration dip-switch is located at the upper right
side of the back of the module.
For dip switch settings,
use the tool that is supplied with the
sound module.
DOOR PANEL INSTALLATION
116
DOOR PANEL INSTALLATION
inary coding of the SW2 configuration dip switch
B
the sound module.
of
The switches set to OFF have null value. The values of the switches
set to ON are shown in the enclosed chart.
The backbone code will be calculated as the sum result of the
switches values set to ON.
Example: 64+0+16+0+4+2+1=87
Switch number:
ON value:
4
64
5
32
6
16
7
8
8
4
9
2
10
1
escription of the SW2 configuration dip-switch of
D
the sound module.
Allows to activate the autoswitch-on function (audio-video communication
without previous call) at the door panel that has thisswitchtoONposition.
In systems with several door panels activate this function only in one of
them; in systems with general door panel this function can be activated in
one door panel of each inner backbone (building).
Set to ON for monitor or telephones programming.Oncetheprogramming
progress is finished return the switch to OFF position. The programming
process is described on pages 128 (monitors), 131 and 135 (telephones).
In general door panel (EL501 mode), set to ON for general door panel
push buttons programming or backbone (building) monitor/telephones.
The programming process is described on pages 117 to 119. Once the
programming progress is finished return the switch to OFF position.
Set to OFF in case of a master door panel. Each system must have only one
master door panel; the rest must be slaves (ON).
In systems with general door panel, set as master one door panel of each
inner backbone (building) and the general door panel as slave. Of this
way, the user will be able to distinguish since door panel are calling him.
Switches number 4 to 10 set the building code. In backbones with several
door panels, set the same code in all the panels; in systems with general
door panel, set different codes for each inner backbone (building). Set a
code between 1 and 120 for inner backbones (up to 127 with coded
panel) and a code 0 ( ) for general door panel/s. To set the
code use binary coding as shown on the next paragraph.
Factory default
Factory default
The SW2 configuration dip-switch is located at the upper left
side of the back of the module.
For dip switch settings,
use the tool that is supplied with the
sound module.
117
Configure the EL631/Plus of the general door panel in EL501 mode, (see page 115).module
Locate the SW2 configuration dip switch of the general door
panel to program, placed at the upper left side (back) of the
sound module. With the switches 1 and 3 to OFF, set the
switch 2 to ON: to show that the system is ready for
programming,the general door panel will reproduce a tone.
Pick up the monitor/telephone handset of
the apartment to program and press the
door release push button until to establish
communication of audio with the general
door panel.
Press the general door panel push button that will call to this
monitor or telephone. At this moment the general door
panel will reproduce a tone. To finish the push button
programmation, replace the monitor/telephone handset;
to show that the push button has been succesfully
programmed, the general door panel will reproduce a tone.
Make a call to check that the push button has been succesfully programmed.
Repeatthese steps to program the rest of push buttons.
Once the programming has been finished, set to OFF the programming
switch. If you don't, the general door panel will reproduce a tone to advise
that the system is still into programming mode.
eneral door panel (programming modes).
G
This programming mode allowsto assign a monitor / telephone (programmed) to thepush button of
the general door panel that it wishes to call.
Before the monitors/telephones of the inner door panel/s must be programmed, see page 128
(monitors), 131 and 135 (telephones).
IMPORTANT: Before programming the general door panel push buttons, switch off the porter's
exchange (if exists).
Programming the push button (by call of monitor/telephone):
T-940Plus T-740Plus
The general door panel permits the following programming modes:
O Programming the push button (by call of monitor).
O Programming the push button (with a backbone code).
O Programming the push button (with a monitor/telephone code).
O Programming the monitor/telephone.
rogramming the push buttons of the general door panel.
P
GENERAL DOOR PANEL INSTALLATION
118
GENERAL DOOR PANEL INSTALLATION
Define a backbone code to program with dip switches Sw2-4 to Sw2-
10. Set a code between 1 and 120. To set the code use binary
coding,(see page 116).
Press the general door panel pushbuttonthat is wished has this
backbone code. At this moment the general door panel will
reproduce a tone, confirming that the push button has been
succesfully programmed.
Repeat these steps to program the rest of push buttons. Once the programming has been finished,
set to OFF the programming switch. If you don't, the general door panel will reproduce a tone to
advise that the system is still into programming mode.
Programming the push button (with a monitor/telephone code):
This programming mode allows to assign a monitor/telephonecode to push button of the general
doorpanel.
Locate the SW2 configuration dip switch of the general door
panel to program, placed at the upper left side (back) of the
sound module. With the switches 1 and 3 to ON, set the
switch 2 to ON: to show that the system is ready for
programming,the general door panel will reproduce a tone.
Press the general door panel pushbuttonthat is wished has this
monitor/telephone code. At this moment the general door
panel will reproduce a tone, confirming that the push button
has been succesfully programmed.
Repeat these steps to program the rest of push buttons. Once the programming has been finished,
set to OFF the programming switch. If you don't, the general door panel will reproduce a tone to
advise that the system is still into programming mode.
Define a monitor/telephone code to program with dip switches Sw2-4
to Sw2-10. Set a code between 1 and 120. To set the code use
binary coding, (see page 116).
Programming the push button ( ):with a backbone code
Thisprogrammingmodeallowsto assigna backbonecode topushbuttonof the generaldoorpanel.
Locate the SW2 configuration dip switch of the general door
panel to program, placed at the upper left side (back) of the
sound module. With the switch 1 to ON and 3 to OFF, set the
switch 2 to ON: to show that the system is ready for
programming,the general door panel will reproduce a tone.
119
GENERAL DOOR PANEL INSTALLATION
DOOR PANEL INSTALLATION
This programming mode allows toassignto a monitor / telephone apushbutton of the general door
panel that it wishes to call.
Before the push button of the general door panel must be programmed with backbone and
monitor/telephone code, (see page 118).
Programming the monitor/telephone:
Locate the SW2 configuration dip switch of the general door
panel to program, placed at the upper left side (back) of the
sound module. With the switch 1 to OFF and 3 to ON, set the
switch 2 to ON: to show that the system is ready for
programming,the general door panel will reproduce a tone.
Then program the monitor/telephone, as it is described in the page 128 (monitor), 131 and 135
(telephone), (see manual T1ML if the monitor/telephone is Platea Uno, T-740 Uno or T-940
Uno).
Bear in mind theconfiguration dip switch (as it is described in theprevious step).
rogramming the monitors and telephones from a general door panel.
P
escription of the function connector CN5.
D
The function connector Cn5is located at theupper left side of the back of
the sound module.
Plug the cable that is supplied with the module, to realize the following
functions:
10
1
9
2
8
3
7
4
6
5
Top view CN5
Description connector CN5
ð"AP" function: It activates the relay of the lock release "CV1" and "Cv2", configurable activation
timeof3or15 seconds viadipswitchSW1-2 (page115),see connections(page 149).
ð"ICO" function: Forthe busy channel indication, it will be realized with terminals "ICO" and "+12".
ð"Handicap" function: Synthese vocale from FDI (France). The connector includes all wires for
connection (see page 149).
1 Grey (-) Ground.
2 Brown (+12) 12Vdc for activation the lock release.
3 White (ICO) Busy channel indicator.
4 Yellow (AP) External push button to activate the lock release.
5 Violet (+H) For activation of an external illumination.
6 Blue (OP) Handicap.
7 Orange (SC) Handicap.
8 Green (ALM) Handicap.
9 Red (PDB) Handicap.
10 Black (-) Ground.
120
DOOR PANEL INSTALLATION
inal adjustments.
F
If after starting the system it
volume isn
't correct, proceed with the necessary
adjustments as shown
in the drawing
.
The telecamera has a pan and tilt mechanism built in to
adjust the telecamera position.
's considered that the audio
lace the nameplate labels.
P
Open the label holder.
Place the label and
close.
Once finished the works of wiring, configuration and
final adjustments, fix the frame in the embedding
box with the supplied screws.
lose the frame.
C
121
DOOR PANEL INSTALLATION
lose the door panel.
C
oor panel assembly.
D
In assemblies of a single door panel, it is ready from factory
to be mounted.
IMPORTANT:
To make these adjustments of joining several door panels, see the
document that is supplied with the door panel and follow the
steps that are described in the section" Mechanical assembly
for double door panel" and once finished the adjustments stick
the adhesive gasket (that is supplied with the push buttons
module) in the rod of joining modules.
If the door panel to installing is of more than one module it will be
necessary make some adjustments to join a door panel with
other one.
Fix the door panel by using the supplied screws.
Finish the door panel assembly by placing the closing
heads, put the head on one sideand then make a slight
pressure on the other end, to its correct placement.
122
LOCK RELEASE INSTALLATION
nstalling the FA-PLUS and FA-PLUS/C power supplies.
I
DIN 46277
3,5 x 25
DIN-7971
3,5 x 25
DIN-7971
M 4 x 8
3,5 x 25
DIN-7972
DIN-963
POWER SUPPLY INSTALLATION
ock release installation.
L
Replace the protection cover once the input terminals have been wired.
It's recommended to protect the power supply by using a
thermo-magnetic circuit breaker. Use a ground
connection with FA-Pluspower supply.
To install the power supply directly on the wall, drill two holes of
Ø6mm. and insert the wallplugs. Fix the transformer with the
specified screws.
The power supply can be installed on a DIN 46277
guide simply pressing it.
To disassemble the power supply from the DIN guide,
use a plain screwdriver to lever the flange as shown
on the picture.
The FA-Plus/C model uses 6 units over DIN guide and
10 units the FA-Plusmodel.
IMPORTANT: the maximum number of units that can be connected to a FA-Plus/C power supply is
10, and 50 units in case of a FA-Plus model. Link power supplies to connect more
units than the specified as it's shown on page 136.
If the lock release will be installed in a metal door, use a
Ø3,5mm.
drill and tap the hole
. In case of wood door, use a Ø3mm. drill.
IMPORTANT: the lock release must be of 12Vd.c. or a.c.
See page 136 (a.c. lock releases) and page 137 to 148 (d.c lock releases)
Install the power supply in a dry and protected place without risk of drip or water projections.
To avoid an electrical shock, neither remove the primary protection cover nor handle the connected
wire in the terminals.
The installation and handling of these equipments must be performed by authorised personnel and
without the power connected.
Toavoid damage, the power supply has to be firmly fixed.
123
j
lk
m
a.
b.
c.
d.
e.
f .
g.
h.
i .
j .
k.
l .
m.
Handset.
B/W or color screen (depending on the model).
Front film.
Function push buttons.
Cord.
Attachment holes.
Identification label.
Connecting points.
CN4 connector.
Three positions call reception volume control.
Cable slot.
Contrast control (color control in case of color screen).
Brightness control.
MONITOR DESCRIPTION
escription of the Platea Plus / Tekna Plus monitor.
D
a
b
e
d
c
f
g
i
h
PLATEA-PLUS
REF
11758802
CODE
10060045
VERSION
5.00
Nº SERIE
100615137263
MASTERSLAVE
INTER A1
CODIGO / CODE
PUERTAESCALERA PISO
Floor DoorStair
ATENCIÓN
Alta tensión. No abrir la tapa.
Manipular sólo por personal
del servicio técnico.
WARNING
High voltage. Don't open cover.
Handle only by technical service.
124
MONITOR DESCRIPTION
unction push buttons.
F
escription of the identification label.
D
PLATEA-PLUS
REF
11758802
CODE
10060045
VERSION
5.00
Nº SERIE
100615137263
MASTERSLAVE
INTER A1
CODIGO / CODE
PUERTAESCALERA PISO
Floor DoorStair
ATENCIÓN
Alta tensión. No abrir la tapa.
Manipular sólo por personal
del servicio técnico.
WARNING
High voltage. Don't open cover.
Handle only by technical service.
On-Off push button. After any monitor reset and during the next 45 seconds, all the
monitor functions will be disabled, with the exception of call reception.
If the handset is on the craddle allows the activation of an optional second camera (*). If
not, allows to make an intercom call or to activate the second camera (*).
If the handset is on the craddle allows the activation of an optional device. If not, allowsto
call to a slave porter's exchange (*) or to activate the optional device.
If the handset is on the craddle allows to see the picture from the master door panel. If
not, allows to establish audio and video communication with the door panel that has
been configurated with the autoswitch-on function. This function is disabled if a
communication is already established.
If the handset is on the craddle sends a panic call to the porter's exchanges that have
enabled the reception of this type of call. If not, allows to call to the master porter's
exchange. During call reception and communication progresses allows the lock
release activation.
(*) Second camera activation and call to a slave porter's exchange functions require an internal
modification of the monitor. If any of these functions are required, contact with your nearest
authorized distributor.
Second camera activation disables the intercomm function and call function to a slave porter's
exchange disables optional device function.
For an easiest repair, replacement or increasement of
the existing monitors, fill the indentifying label
information.
MASTER: master monitor.
SLAVE: slave monitor.
INTER: slave monitor with intercom function.
A1: monitor connected to an auxiliary device.
CODE: push button code (see page 114).
STAIR: backbone code (building) (see page 116).
125
L562
E
with twisted pair cable.
module for video installations
andling the end of line jumper.
H
hanging the front film.
C
MONITOR ADJUSTMENTS
LocatetheCN4connector, that's placedinthe monitor base. Removethe
existing jumper and plug the EL562 module.
NOTE: on this type of installationsthe sound module must be setting with
SW1-3 to ON (page 115). Referto the specific installation diagram.
The end of line jumper is placed on the CN4 connector, that can be
located on the monitor base.
In case of twisted pair cable installations, the end of line jumper is
placed in the EL562 module, also located in the CN4 connector of the
monitor base.
Do not remove the jumper on monitors where the video cable finish.
Removethe jumper on monitors where the video cable continue.
The monitor Platea Plus is supplied with a reversible front film, that allow
the owner to choose between two colors.
To change the front film, remove the front plate by inserting a plain
screwdriver in the triangle marks, as it is shown on the drawing.
126
V
in
V
out
Malla
Shield
Malla
Shield
A
HZ-
INT
SA
CTO
2C
A1
VP
MP
D
REF
RCPL-PLUS
LOTE
CODE
11758882
Colocar la parte superior de la regleta a 1,60m. del suelo.
Place the top part of the monitor connector at 1,60m. from the floor.
50mm.
50mm.
Presionar para abrir.
Press to open.
escription of the RCPL-Plus / RCTK-Plus
D
monitor connector.
a
a
b
b
f
e
d
c
a. Wall attachment hole (x4).
b. Monitor attachment hook (x2).
c. Vertical wiring input.
d. Attachment clip.
e. Wiring input hole.
f. Installation terminals:
positive, ground.
video signal coaxial input.
coaxial shield.
video signal coaxial output.
audio communication.
digital communication.
door bell push button input.
intercom.
auxiliary calling device output.
video distributor activation output.
2nd camera activation output.
optional device activation output.
twisted pair video signal.
+, –:
Vin :
Malla:
Vout :
A :
D :
HZ- :
INT :
SA :
CTO :
2C :
A1 :
Vp, Mp :
MONITOR CONNECTOR DESCRIPTION
Terminals +, and Malla (shield) are duplicated for easiest cascade installation of parallel
monitors or telephones. If the first monitor is not placed on the connector, cascade units will not
be powered.
127
MONITOR INSTALLATION
ix the monitor connector to the wall.
F
ix the monitor.
F
Avoid to place the monitor near to heating sources, in dusty
locations or smoky environments.
To install the monitor directly over the wall, drill two holes of
Ø6mm. and use the supplied screws.
The upper part of the monitor connector must be placed
at 1,60m. height roughly. The minimum distance
between the monitor connector and the closest object
must be 5cm.
Place the monitor at right angles to the
connector and align the attaching holes of the
monitor with the attachment hooks of the
connector, as it is shown on the drawing.
Lock out the monitor. Press the right side till the
attachment clip locks the monitor firmly.
To disassemble the monitor from the connector,
use a plain screwdriver to release the
attachment clip. Remove the monitor from the
connector, with special attention do not falls.
128
MONITORS PROGRAMMING
rogramming the Platea Plus / Tekna Plus monitors.
P
Set to ON the switch number 2 of the SW2 configuration dip switch, placed
at the upper left side (back) of the module EL631/Plus. The door panel
will reproduce a sound to advise that the system has entered into
programming mode.
In systems with more than one door panel, the programming process shall
be done on the master door panel only.
To program the monitor from a general door panel (if it exists), see page 119.
Switch off the monitor to be programmed.
Once the monitor is off, press the door release push button.
With the door release push button pressed switch on the
monitor.
To show that the system is ready for programming, the door
panel will reproduce a tone and the picture will appears
on the monitor. At this moment, the door release push
button can be released. Lift the handset to establish audio
communication with the door panel.
Press the door panel push button that will
call to this monitor. At this moment the
door panel will reproduce a tone and the
monitor led will blink.
To program the monitor as master, switch it
off and on again.
To program it as slave, press the door
release push button.
To program it as slave with intercom
function press the push button.
Each apartment must have one master unit only; in case of parallel units configure them as slaves,
both monitors or telephones.
Make a call to check that the monitor has been succesfully programmed.
Repeatthese steps to program the rest of monitors.
Once the programming has been finished, set to OFF the programming
switch. If you don't, the door panel will reproduce a tone to advise that the
system is still into programming mode.
129
TELEPHONE DESCRIPTION
escription of the T-940 Plus telephone.
D
a.
b.
c.
d.
e.
f.
g.
h.
i.
Telephone handset.
Speaker grille.
Microphone hole.
Subjection hole.
Telephone cord connectors.
Function push buttons.
On-Off light indicator.
Call reception volume control.
Hook switch.
a
d
c
e
i
h
e
b
f
g
unction push buttons.
F
a.
b.
c.
a
b
c
The telephone has a three positions switch placed on the bottom
part of the telephone (closest to the telephone cord connector)
that allows to control the call reception level volume.
On-Off push button.
After any telephone reset, and during the next 45 seconds, all the
telephone functions will be disabled, with the exception of call
reception.
This push button allows to make an intercom call when the handset
is not on the craddle. This function is described on page 152.
If the handset is on the craddle sends a panic call to the porter's
exchanges that have enabled the reception of this type of call. If
not, allows to call to the master porter's exchange. During call
reception and communication progresses allows the lock release
activation.
130
TELEPHONE DESCRIPTION
erminal connector description.
T
positive, ground.
audio, digital communication.
intercom.
auxiliary calling device output.
door bell push button input.
+ , :
A , D :
INT :
SA :
HZ- :
AD
+
_
SAINT HZ-
TELEPHONE INSTALLATION
ix the telephone.
F
It will be necessary to open the telephone for wiring and
fixing purposes. To open the telephone insert a plain
screwdriver into the slots and rotate it as shown.
Avoid to place the telephone near to
heating sources, in dusty locations or
smoky environments.
The telephone can be fixed using an
electrical embedding box or directly on
the wall, as shown on the picture. If the
telephone will be installed directly over
the wall, drill two holes of Ø6mm. on the
specified positions, using 6mm.
wallplugs and Ø3,5 x 25mm. screws.
Pass the installation wires through the corresponding hole and
connect them as shown on the installation diagrams.
Close the telephone as shown on the picture. Once the telephone
is closed, connect the handsetusing the telephone cord and put
it on the craddle.
131
TELEPHONES PROGRAMMING
rogramming the T-940 Plus telephones.
P
Switch off the telephone to be programmed.
Once the telephone is off, press the door release push button.
Set to ON the switch number 2 of the SW2 configuration dip switch, placed
at the upper left side (back) of the sound module. The door panel will
reproduce a sound to advise that the system has entered into
programming mode.
In systems with more than one door panel, the programming process shall
be done on the master door panel only.
To program the telephone from a general door panel (if it exists), see page 119.
To show that the system is ready for programming, the door
panel will reproduce a tone and the telephone led will blink.
At this moment, the door release push button can be
released. Lift the handset to establish audio communication
with the door panel.
With the door release push button pressed switch on the
telephone.
Press the door panel push buttonthat will call
to this telephone. At this moment the door
panel will reproduce a tone and the
telephone led will blink.
To program the telephone as master, switch it
off and on again.
To program it as slave, press the door release
push button.
To program it as slave with intercom function
press the center push button.
Each apartment must have one master unit only; in case of parallel units configure them as
slaves, both monitors or telephones.
Make a call to check that the telephone has been succesfully programmed.
Repeatthese steps to program the rest of telephones.
Once the programming has been finished, set to OFF the programming
switch. If you don't, the door panel will reproduce a tone to advise that the
system is still into programming mode.
132
erminal connector description.
T
+, - :
A , D :
Al :
HZ :
SA :
INT :
PA :
Al+SA
_
AD Int PA
_
HZ +
TELEPHONE DESCRIPTION
.
D
escription of the T-740 Plus telephone
a
d
c
e
b
g
e
a.
b.
c.
d.
e.
f.
g.
h.
i.
Telephone handset
Speaker grille
Microphone hole
hole
Telephone cord connectors
release push button
Hook switch
Auxiliary function push button
Volume control
.
.
.
Subjection .
.
Door .
.
.
.
f
h
i
all volume control.
C
The telephone allows to regulate the call volume with a maximum,
medium and off value. With the help of the switch of three positions
placed in the right front of the telephone.
Positive, ground.
SAV-90
Audio, digital communication.
Connection to external door release push button.
Door bell push button input.
Auxiliary calling device output
Intercom.
(18Vdc/0,5A max.)
.
Output for aux. relay activation
133
.
F
unction push buttons
TELEPHONE DESCRIPTION
If the handset is on the craddle sends a panic call to the porter's
exchanges that have enabled the reception of this type of call. If not,
allows to call to the master porter's exchange. During call reception
and communication progresses allows the lock release activation.
Auxiliary function push button, depending on setting in the SW1 dip
switch will realize one of the following functions: Autoswitch-on, "PA"
output, call to a slave porter's exchange and intercommunication.
escription of configuration dip switch.
D
escription of programming push button.
D
Factory default
"Autoswitch-on" mode: switches 1 and 2 to ON.
With the handset off the cradle, allows to stablish audio communication with the
door panel that has been configured with the autoswitch-on function. This
function is disabled if a communication is already established.
"PA" output mode: switches 1to ON and 2 to OFF:
Regardlessof the handset's position, it activates the "PA" telephone output.
"C " mode: switches 1 to OFF and 2 to ON.
With the handset off the cradle, allows to call to a porter's exchange that it is
configurated as slave.
all to a slave porter's exchange
" " mode: switches 1 and 2 to OFF.
With the handset off the cradle, allows to make an intercom call between two units
of the same apartment.
Intercommunication
The P3 programm push button is located in the top part left of the circuit,it is
accessed by opening the telephone. Allows to telephone enter in programming
mode with the door panel, (see programming process on page 135).
IMPORTANTE: Select before programming the telephone.the auxiliary function push button mode
The SW1 configuration dip switch is located in the top part left of the circuit,it is
accessed by opening the telephone and allow the next operation modes for the
auxiliary function push button:
P3
SW1
12
12
12
12
12
P3
12
134
ix the telephone to the wall
F
.
It is necessary to open the telephone for wiring and fixing
purposes To open the telephone, insert a plain screwdriver
into the slots and gently lever as shown in the drawing
.
.
P
.C
.
.
ass the installation wires through the corresponding hole and connect
them as shown on the installation diagrams lose the telephone as
shown on the picture Once the telephone is closed, connect the
handset using the telephone cord and put it on the cradle
Avoid placing the telephone near sources of heat, in dusty
locations or smoky environments The telephone can be
fixed using an electrical embedding box or directly on the
wall, as shown on the picture If the telephone will be
installed directly over the wall, drill two holes of Ø6mm on
the specified positions, using 6mm wall plugs and Ø3.5 x
25mm screws
.
.
.
TELEPHONE INSTALLATION
135
rogramación de los teléfonos T-740 Plus.
P
To show that the systemisreadyforprogramming,
the door panel and the telephone's handset will
reproduce a tone (the telephone led will light).
Audio communicationcanbeestablished.
Press the door panel push button that will call to
this telephone. At this moment both door
panel and handset will reproduce tones (the
telephone led will slow blink).
To programm the telephone as Master, press the
h (the telephone led will off).
Closethetelephone.
ook switch
Set to ON the switch number 2 of the SW2 configuration dip switch, placed at
the upper left side (back) of the sound module. The door panel will reproduce a
sound to advise that the system has entered into programming mode. In systems
with more than one door panel, the programming process shall be done on the
master door panel only.
Each apartment must have one master unit only; in case of parallel units configure them as slaves,
both monitors or telephones.
Make a call to check that the telephone has been succesfully programmed. Repeat
these steps to program the rest of telephones.
Once the programming has been finished, set to OFF the programming switch. If
you don't, the door panel will reproduce a tone to advise that the system is still
into programming mode.
To programm the telephone as Slave, press the
P1 door release push button (the telephone
led will quick blink) and later press the hook
switch (the led will off).
Closethetelephone.
Open the telephone to programming (see page
134). Select in the SW1 dip switch the fuction
mode for the auxiliary
(see page 133) and later press the P3
programming push-button.
function push button
To programm the telephone as Slave +
Intercom., press the P2 auxiliary function
push button (the led will quick blink) and later
press the hook switch (the led will off).
Closethetelephone.
To program the telephone from a general door panel (if it exists), see page 119.
TELEPHONES PROGRAMMING
P3
1 2
P3
ON
P3
ON
P3
ON
P3
ON
P3
SW1
1 2
P1
P2
CN1
M
S
SI
P1
P2
CN1
P3
SW1
P1
P2
CN1
ON
P3
ON
P3
SW1
P1
P2
CN1
ON
P3
SW1
P1
P2
CN1
ON
136
INSTALLATION DIAGRAMS
onnexion of an a.c. lock release.
C
ink of several power supplies units.
L
1st FA-Plus 2nd FA-Plus/C or FA-Plus
SEC
PRI
~~
Main
++
--
SEC
PRI
~~
Main
++
--
If an alternating current lock release has been installed, use a TF-104 transformer and connect it to
the lock release as it is shown on the diagram.
If the quantity of monitors or telephones to be connected is bigger than the supported from one
power supply (see page 122), use additional power supplies to match the required quantity. The
first power supply should be connected to the door panel and to the first group of monitors or
telephones; connect the next groups to the positive terminal of its corresponding power supply.
To wire several power supplies link their ground terminals.
NEVER link positive terminalsof different power supplies.
To the door panel & to the first
group of monitors/telephones.
To the second group of
monitors/telephones.
Main
CN2
+
--
+CV1CV2
SEC
PRI
230110 0
--
++
EL631 PLUS /
EL640 PLUS
FA-PLUS/C
rev.938072
Main
TF-104
SEC
PRI
~~~~
Lock release
Va.c.
137
FA-Plus/C o FA-Plus
SEC
PRI
~~
++
--
A
A
_
_
+
+
D
D
Malla
Malla
V
in
V
in
V
out
V
out
CN4
CN4
A
_
+
D
Malla
V
in
V
out
CN4
A
_
+
D
Malla
V
in
V
out
CN4
E
E
D1
D1
D2
D2
+
+
D4L-PLUS
D4L-PLUS
JP1
JP1
S
S
SW1SW2
P
D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN2
+
-
+CV1CV2
-
10
1
9
2
8
3
7
4
6
5
CN5
Main
Place this power supply
as closest as possible
to the first distributor.
Take off JP1 jumper
of all the distributors
except in the last one.
INSTALLATION DIAGRAMS
Access door panel
M =Master.
S =Slave.
Lock release
Vd.c.
138
SW1
FA-Plus/C
rev.938072
SEC
PRI
230110 0
--
++
SW2
S
D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN2
+
-
+CV1CV2
-
10
1
9
2
8
3
7
4
6
5
CN5
Main
ONE OR SEVERAL ACCESSES DOORS
ideo installation with coaxial cable.
v
1,00mm² 2,50mm²
0,25mm² 0,25mm²
RG-59 RG-59
Terminal
SECTIONS CHART
50m.
Distance
150m.
A , A , A, D
in out
V , V , V , V
in+ out+ in out
+, , CV1, CV2
oaxial cable characteristics RG-59 B/U MIL C-17.
C
Core max. electrical resistence to 20ºC
Copper core
Copper shield
ELECTRICAL CHARACTERISTICS
Nominal capacitance
Characteristic impedance
VALUES
*
Velocity of Propogation
Access door panel
**
The installation diagram shows the connection of a video system with one or several door panels
for the same building.
If the system has one access door panel only, override the wiring to the second door panel.
If the system has more than one access door panel, wire the second panel as shown on the
diagram. In case of more than two door panels, wire them as the second is connected.
Lock release
Vd.c.
75 3
+
-
<67pf/m
<158 /Km
<10 /Km
_
_
_
_
>66,6 %
139
INSTALLATION DIAGRAMS
FA-Plus/C o FA-Plus
SEC
PRI
~~
++
--
JP1
A
A
D
D
CT
+
+
V
pi
V
d1
M
pi
M
d1
_
_
A
D
CT
+
V
d6
M
d6
_
AD+
V
po
M
po
_
D6L-Plus/2H
V
p
M
p
AD
_
+
EL562
JP1
V
p
M
p
AD
_
+
EL562
JP1
JP1
A
A
D
D
CT
+
+
V
pi
V
d1
M
pi
M
d1
_
_
A
D
CT
+
V
d6
M
d6
_
AD+
V
po
M
po
_
D6L-Plus/2H
V
p
M
p
AD
_
+
EL562
JP1
V
p
M
p
AD
_
+
EL562
JP1
SW1SW2
P
D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN2
+
-
+CV1CV2
-
10
1
9
2
8
3
7
4
6
5
CN5
Main
* Take off JP1 jumper
of all the distributors
except in the last one.
* Place this power supply
as closest as possible
to the first distributor.
Access door panel
M =Master.
S =Slave.
Lock release
Vd.c.
140
ONE OR SEVERAL ACCESSES DOORS
SW1SW2
FA-Plus/C
rev.938072
SEC
PRI
230110 0
--
++
S
D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN2
+
-
+CV1CV2
-
10
1
9
2
8
3
7
4
6
5
CN5
Main
1,00mm² 2,50mm²
0,25mm² 0,25mm²
CAT-5 CAT-5
Terminal
SECTIONS CHART
50m.
Distance
150m.
A , A , A, D
in out
V , V , V , M
in+,- out+,- p,d p,d
+, , CV1, CV2
ideo installation without coaxial cable.
v
Access door panel
The installation diagram shows the connection of a video system with one or several door panels for
the same building.
If the system has one access door panel only, override the wiring to the second door panel.
If the system has more than one access door panel, wire the second panel as shown on the diagram.
In case of more than two door panels, wire them as the second is connected.
IMPORTANT: For this type of installation, the door panels must have configured t
he switch nº.3 of
the SW1 configuration dip-switch to ON
in each (page 115) and the monitors must
have an EL562 plugged in each (page 125).
Lock release
Vd.c.
141
INSTALLATION DIAGRAMS
FA-Plus/C o FA-Plus
SEC
PRI
~~
++
--
A
A
+
+
_
_
D
D
T-740 Plus
T-740 Plus
A
+
_
D
T-940 Plus
A
+
_
D
T-940 Plus
SW2 SW1
P
D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN2
+
-
+CV1CV2
-
10
1
9
2
8
3
7
4
6
5
CN5
Main
*Place this power supply
as closest as possible
to the first telephone.
Access door panel
M =Master.
S =Slave.
Lock release
Vd.c.
142
ONE OR SEVERAL ACCESSES DOORS
SW2 SW1
S
D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN2
+
-
+CV1CV2
-
10
1
9
2
8
3
7
4
6
5
CN5
FA-Plus/C
rev.938072
SEC
PRI
230
--
110 0
++
Main
udio installation.
A
1,00mm² 2,50mm²
0,25mm² 0,25mm²
Terminal
SECTIONS CHART
50m.
Distance
150m.
A , A , A, D
in out
+, , CV1, CV2
Access door panel
The installation diagram shows the connection of an audio system with one or several door panels
for the same building.
If the system has one access door panel only, override the wiring to the second door panel.
If the system hasmore than one access door panel, wire the second panel as shown onthe diagram.
In case of more than two door panels, wire them as the second is connected.
Lock release
Vd.c.
143
To monitors
Main
Inner door panel
Main
General door panel
EL501 mode
EL500 mode
BACKBONE 1
INSTALLATION DIAGRAMS
M =Master.
S =Slave.
BACKBONE 0
SW1SW2
ES +
S1
D4L-PLUS
JP1
FA-Plus o FA-Plus/C
SEC
PRI
~~
++
--
FA-Plus/C
rev.938072
SEC
PRI
230
--
110 0
++
SW2 SW1
S
P
D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN2
+
-
+CV1CV2
-
10
1
9
2
8
3
7
4
6
5
CN5
D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN2
+
-
+CV1CV2
-
10
1
9
2
8
3
7
4
6
5
CN5
Lock release
Vd.c.
Lock release
Vd.c.
144
To monitors
Continues
in the following page
Main
EL501 mode
Main
General door panel
EL500 mode
BACKBONE 2 Inner door panel
GENERAL DOOR PANEL
BACKBONE 0
ES +
S1
SW2
D4L-PLUS
JP1
SEC
PRI
~~
++
--
FA-Plus o FA-Plus/C
SW1
FA-Plus/C
rev.938072
SEC
PRI
230
--
110 0
++
P
SW2 SW1
S
D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN2
+
-
+CV1CV2
-
10
1
9
2
8
3
7
4
6
5
CN5
D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN2
+
-
+CV1CV2
-
10
1
9
2
8
3
7
4
6
5
CN5
Lock release
Vd.c.
Lock release
Vd.c.
145
INSTALLATION DIAGRAMS
ES
+
S1
S2
D4L-PLUS
JP1
SW2
FA-Plus o FA-Plus/C
SEC
PRI
~~
++
--
P
D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN2
+
-
+CV1CV2
-
10
1
9
2
8
3
7
4
6
5
CN5
SW1
Coming
from previous page
ideo installation with
to large residential complexes.
v
general door panel
Malla
Vin- Vin+ Vout-Vout+
Malla
Vin- Vin+ Vout-Vout+
IMPORTANT NOTES:
To install and configure properly, d
The installation diagram shows the connection of a video system with two general door panels and up to
120 inner door panels (backbones/buildings).
In case of more than two door panels, wire them as the second is conected.
In video systems use a D4L-Plus distributor before each inner building except in the last one. Take off JP1
jumper of all the distributors except in the last one.
In video systems with use the D6L-Plus/2Hdistributor instead of D4L-Plusdistributor. Take off
JP1 jumper of all the distributors except in the last one. Add a negative in the inner building
installation riser, (see page 139).
Below shows the connection of the
coaxial cable.
o always follow the enclosed information.
twisted pair
twisted
pair instead of
To monitors
Main
Inner door panel
EL500 mode
BACKBONE 119
Lock release
Vd.c.
146
GENERAL DOOR PANEL
SW2
SEC
PRI
~~
++
--
FA-Plus o FA-Plus/C
P
D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN2
+
-
+CV1CV2
-
10
1
9
2
8
3
7
4
6
5
CN5
SW1
ideo installation with general door panel
to large residential complexes.
v
For greater distances contact our technical support department.
1,50mm² 2,50mm²
0,25mm² 0,25mm²
CAT-5
RG-59
Terminal
SECTIONS CHART
100m.
Distance
300m.
A , A , A, D
in out
V, V
in+ out+
V , V , V , V
in+ in- out+ out-
+, , CV1, CV2
RG-59
CAT-5
Coaxial
Sw1-3 Off
Twisted pair
Sw1-3 On
*
Coaxial cable characteristics RG-59 B/U MIL C-17, (see page 138).
**
To monitors
Main
EL500 mode
BACKBONE 120 Inner door panel
Lock release
Vd.c.
147
INSTALLATION DIAGRAMS
SW1SW2
FA-Plus o FA-Plus/C
SEC
PRI
~~
++
--
FA-Plus/C
rev.938072
SEC
PRI
230
--
110 0
++
SW2 SW1
S
P
D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN2
+
-
+CV1CV2
-
10
1
9
2
8
3
7
4
6
5
CN5
D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN2
+
-
+CV1CV2
-
10
1
9
2
8
3
7
4
6
5
CN5
To telephones
Main
Main
General door panel
Inner door panelBACKBONE 1
EL501 mode
EL500 mode
BACKBONE 0
M =Master.
S =Slave.
Lock release
Vd.c.
148
GENERAL DOOR PANEL
SEC
PRI
~~
++
--
SW2
FA-Plus o FA-Plus/C
SW1
P
D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN2
+
-
+CV1CV2
-
10
1
9
2
8
3
7
4
6
5
CN5
To telephones
udio installation with general door panel
A
to large residential complexes.
1,50mm² 2,50mm²
0,25mm² 0,25mm²
Terminal
SECTIONS CHART
100m.
Distance
300m.
A , A , A, D
in out
For greater distances contact our technical support department.
+, , CV1, CV2
Main
IMPORTANT NOTES:
To install and configure properly, d
The installation diagram shows the connection of an audio system with one general door panel
and up to 120 inner door panels (backbones/buildings).
In case of more than one general door panel, wire them as it shows in the video installation
diagram, (see page 143).
o always follow the enclosed information.
BACKBONE 120 Inner door panel
EL500 mode
Lock release
Vd.c.
149
OPTIONAL CONNECTIONS
xternal lock release activation.
E
The lock release can be activated at any moment by using an
external push button, that must be connected between 'AP' and ' '
terminals of the connector Cn5 from door panel (see page 119).
Door opening timed at 3 or 15 seconds, with the help of the dip
switch SW1-2 (see page 115).
This function will allows to exitfromthe building being not necessary
the use of a key.
Placa
CN2
-
CV1CV2
10
1
9
2
8
3
7
4
6
5
CN5
AP
Lock release
Vd.c.
FA-Plus/C o FA-Plus
SEC
PRI
~~
Main
++
--
SW1SW2
P
D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN2
+
-
+CV1CV2
-
10
1
9
2
8
3
7
4
6
5
CN5
To monitors
PRI
~~
~~
SEC
TF-104
Main
OP
SC
ALM
PDB
Red
Ye
llo
w
Green
JA
SC
12 -
OP
R
CA
12 +
ALM
PDN
PDB
MAS
PDG
VE
RO
GND
J1
J2
J6
J7
3
2
1
3
2
1
1
2
3
1
2
3
HCP
SYNTHESE VOCALE
onnection to the synthese vocale module of FDI (for France).
C
Lock release
Vd.c.
150
OPTIONAL CONNECTIONS
uxiliary devices activation.
A
The use of a TF-104 transformer will be necessary to activate a second lock release.
A
_
+
D
Malla
V
in
V
out
CN4
Platea Plus /
Tekna Plus
220 Vac/
1.8A max.
SAR-12/24
P
N
IN IN
NC NA C
( )
*
The neutral supply from the stairs light will be wired through the relay contacts SAR-12/24, the maximum current for stairs
light will be 1.8A.
( )
*
To distributor/
door panel.
To stairs light
push button
~~ ~~
Lock release
Vac.
TF-104
Main
PRI
SEC
SAR-12/24
IN IN
NC NA C
A1
A
_
+
D
Malla
V
in
V
out
CN4
To distributor/
door panel.
A1
To activate auxiliary devicesthe use of a SAR-12/24 relay unit will berequired. If this device isshared
for all monitors, link their A1 terminal and use just one relay unit. In case that each monitor has its
own application use a SAR-12/24 relay unit for each monitor and don't link the A1 monitor
terminals.
To activate this function, press monitor push button at any moment with no dependence of the
handset position.
Usual applications are the activation of stairs light, second lock release, ...
Platea Plus /
Tekna Plus
151
OPTIONAL CONNECTIONS
onnecting the Platea Plus / Tekna Plus
C
monitor to a video recorder or TV.
ctivation of a second camera.
A
A
_
+
D
Malla
V
in
V
out
CN4
SAR-12/24
IN IN
NC NA C
Platea Plus /
Tekna Plus
2C
2 Camera
nd
The use of a SAR-12/24 relay will be required to activate a second camera and an internal
modification on the monitor shall be done, asit's described on page 124. This facility disables the
intercom function. If both functions are required, use A1 terminal to activate the second camera.
To activate this function, press monitor push button at any moment with no dependence of the
handset position.
If this device is shared for all monitors, link their 2C terminal and use just one relay unit. In case that
each monitor has its own camera use a SAR-12/24 relay unit for each monitor and don't link the
2C monitor terminals.
This push button can be used to activate other auxiliary devices, as the A1 terminal is used.
Usual applications are the surveillance of the elevator entrance, reception hall, ...
A
_
+
D
Malla
V
in
V
out
CN4
Platea Plus /
Tekna Plus
If your TV or video recorder have a SCART connector, it will
be possible to view the picture from the door panel on
the TV screen.
Remove the end of line jumper, that's placed on the CN4
connector. Connect the coaxial cable between terminals
17 (shield) and 20 (hot) of the SCARTconnector.
152
OPTIONAL CONNECTIONS
ntercom function.
I
xternal lock release activation with
E
T-740Plus telephone.
T-740 Plus
Al
_
During call reception and communication progresses allows the
lock release activation, by using an external push button, that
must be connected between 'AI' and ' ' terminals of the
telephone.
A
+
_
DINT
A
_
+
DINT
Malla
V
in
V
out
CN4
Platea Plus /
Tekna Plus
T-940 Plus
T-740 Plus
IMPORTANT: The T-740 Plus telephone must be configured with SW1 dip switch in "Intercom" mode
function
(see page 133).
*
Platea Plus / Tekna Plus monitor and (*) T-740Plus and T-940 Plus telephones have intercom facility
between two units of the same apartment. To enable this function check the following conditions:
- One of the units has been configurated as master and the other unit as slave with intercom, as
described on pages 128, 131 and 135. In case to intercom one monitor with one telephone,
configure the monitor as master.
- Link the INT terminal of the units, as it is shown on the enclosed diagram.
To establish an intercom communication lift the handset and press the intercom push button;
acoustic tones will be reproduced on the handset confirming the call is in progress or that the
other unit is communicating with the door panel. To establish communication lift the handset of
the called unit
. If duringan intercom communication a call is made from the door panel, acoustic
tones will be heard on the master unit handset and the picture will appear in case of a monitor;
press the intercom push button of the masterunitto establish communication with the door panel,
or press the door release push button to activate the lock release.
The reproduced acoustic tones are different depending on their provenance, that allows the user to
distinguish where the call is made from.
153
OPTIONAL CONNECTIONS
oor bell push button connection.
D
A
+
_
D
SAR-12/24
P
N
220 Vac/
1.8A max.
IN IN
NC NA C
( )
*
The neutral supply from thestairs light will be wiredthrough the relay contactsSAR-12/24, the maximumcurrent for stairs
light will be 1.8A.
( )
*
uxiliary devices activation with T-740 Plus telephone.
A
To activate auxiliary devices the use of a SAR-12/24 relay unit will be required. If this device is
shared for all the T-740 Plus telephones, link their PA terminal and use just one relay unit. In
case that each telephone has its own application use a SAR-12/24 relay unit for each
telephone and don't link the PA telephone terminals.
To activate this function, press telephone push button at any moment with no dependence of
the handset position.
Usual applications are the activation of stairs light, second lock release, ...
First t T-740 Plus telephone must be configured with SW1 dip switch in "PA" output mode
function
(see page 133).
he
T-740 Plus
HZ-
-
HZ
-
T-940 Plus
Platea Plus /
Tekna Plus
T-740 Plus
PA
To distributor/
door panel.
To stairs light
push button
The Platea Plus / Tekna Plus monitor and the T-740 Plus and T-940 Plus telephones can be used to
receive the calls made from the apartment door, saving the use of a bell. Wirethepushbuttonof
the apartment door to the 'HZ 'and' 'monitorortelephoneterminals.
The reproduced acoustic tones are different depending on their provenance, that allows the user
to distinguish where the call is made from. If during a conversation a call is made from the
apartment door, acoustic tones will be reproduced on the handset to advise that someone is
calling.
––
154
TROUBLESHOOTING HINTS
An easy way to check that the system is working properly is to disconnect the wiring from the door panel
and to check the monitor directly connected to the sound module.
No shortcircuit will damage the connected units, with the exception of a shortcircuit between CTO and ' '
monitor or distributor terminals.
O Nothing operates.
w Check the output power supply voltage between ' ' and '+' terminals: it should have 17,5 to
18,5Vd.c. If not, disconnect the power supply from the installation and measure again. If it's
correct now, it means there is a short circuit in the installation: disconnect the power supply
from mains and check the installation.
w Check that 'D' terminal is not shortcircuited with ' 'or'+'terminals.
w Check that 'D' terminal hasn't been changed by 'A' terminal somewhere in the installation.
O Inappropriate audio level.
w Adjust the level volumes as shown on page 120. In case of feedback, reduce the audio levels until
feedback fade out. If feedback don't dissapears refer to the following hint.
O Continuous audio feedback.
w Check that 'A' terminal is not shortcircuited with other terminals.
O Door open function no operates.
w Rememberthat this function is only available during call and communication progresses.
w
w
O The system cannot be programmed.
w Check that the switch number 2 of the SW2 configuration dip switch is set to ON (see page 116)
and that the programming steps are correctly followed.
w Check that 'D' terminal is not shortcircuited with other terminals.
O Some units don't receive calls.
w Rememberthateach apartment must have a master unit only. Check that theunits are switched on
and correctly programmed.
O There are no video image.
w Check the number 4 of the dip switch SW1 of the module 631 Plus is in OFF (see page 115).
w Check there is supply in the distributors, the voltage between '+' and '-' terminals should have 15
to 18 Vd.c.
O Push buttons don't work.
w Check that pressing the push button the door panel reproduce an acoustic confirming tone, if
not check the wiring and configuration of the push buttons (pages 113 to 114).
w If confirmation of pulsation exists, check the monitors or telephones programming (pages 128,
131 and 135).
The CV1 and CV2 terminals for door opening are voltage free outputs. The cable requires a
connection depending on whether 12Vdc (page 137 to 148) or 12Vac(page 136) is needed.
Make a short circuit between the 'CV1' and 'CV2' terminals on the sound module; there should
be12V (d.c. or a.c. depending on the type door release installed) between the terminals on the
door release. If so, check the lock release and its wiring.
CONFORMIDAD/COMPLIANCE/CONFORMITÉ
Golmar se reserva el derecho a cualquier modificación sin previo aviso.
Golmar se réserve le droit de toute modification sans préavis.
Golmar reserves the right to make any modifications without prior notice.
golmar@golmar.es
www.golmar.es
Este producto es conforme con las disposiciones de las Directivas Europeas
aplicables respecto a la Seguridad eléctrica 2006/95/CEE y la Compatibilidad
Electromagnética 2004/108/CEE, así como con la ampliación en la Directiva del
Marcado CE 93/68/CEE.
This product meets the essentials requirements of applicable European
Directives regarding Electrical Safety 2006/95/ECC, Electromagnetic Compatibility
2004/108/ECC,and asamended forCE Marking93/68/ECC.
NOTA: El funcionamiento de este equipo está sujeto a las siguientes
condiciones:
(1) Este dispositivo no puede provocar interferencias dañinas, y (2)
debe aceptar cualquier interferencia recibida, incluyendo las que
pueden provocar un funcionamiento no deseado.
NOTE: Operation is subject to the following conditions:
(1) This device may not cause harmful interference, and (2) this device
must accept any received interference, including the ones that may
cause undesired operation.
155
44

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Golmar T631 Plus Nexa bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Golmar T631 Plus Nexa in de taal/talen: Engels als bijlage per email.

De handleiding is 2,02 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info