502925
1
Verklein
Vergroot
Pagina terug
1/48
Pagina verder
Safety Instructions ............ 2, 3
Operating Instructions
.........4, 5
Care and Cleaning
Air Filter ............................. 6
Outdoor Coils ........................ 6
Installation Instructions .....7–10
Troubleshooting Tips ...........11
Normal Operating Sounds ...........11
Consumer Support
Consumer Support ..........Back Cover
Ownership Registration for
Customers in Canada only ........13, 14
Warranty for Customers
in Canada ..........................16
Warranty for Customers
in the U.S.A. ....................... 15
49-7658 12-10 GE
Owner’s Manual and
Installation Instructions
Write the model and serial numbers here:
Model # _________________________
Serial # __________________________
Find these numbers on a label on the side of
the air conditioner.
Air Conditioners
GEAppliances.com
Room
As an EnErgy Star
®
partner, GE has
determined that this product meets
the EnErgy Star
®
guidelines for
energy efficiency.
*EnErgy Star
®
labeled product
Climatiseur
Acondicionador
de aire
Manuel d’utilisation et
instructions d’installation
Manual del propietario
e instrucciones de
instalación
La section française commence à la page 17
La sección en español empieza en la página 35
In Canada, contact us at:
www.GEAppliances.ca
AEQ10
AEM10*
AEQ12
AEM12*
2
IMPORTANT SAFETY INFORMATION.
READ ALL INSTRUCTIONS BEFORE USING.
WARNING!
For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock
or personal injury.
n Use this appliance only for its intended
purpose as described in this Owner’s
Manual.
n This air conditioner must be properly
installed in accordance with the Installation
Instructions before it is used.
n Never unplug your air conditioner by pulling
on the power cord. Always grip plug firmly
and pull straight out from the receptacle.
n Replace immediately all electric service
cords that have become frayed or otherwise
damaged. A damaged power supply cord
must be replaced with a new power supply
cord obtained from the manufacturer and
not repaired. Do not use a cord that shows
cracks or abrasion damage along its length
or at either the plug or connector end.
n Turn the unit OFF and unplug your air
conditioner before cleaning.
n GE does not support any servicing of the
air conditioner. We strongly recommend
that you do not attempt to service the air
conditioner yourself.
n For your safety…do not store or use
combustible materials, gasoline or other
flammable vapors or liquids in the vicinity
of this or any other appliance.
n All air conditioners contain refrigerants,
which under federal law must be removed
prior to product disposal. If you are getting
rid of an old product with refrigerants, check
with the company handling disposal about
what to do.
n If the receptacle does not match the plug,
the receptacle must be changed out by a
qualified electrician.
n These R410A air conditioning systems
require contractors and technicians to
use tools, equipment and safety standards
approved for use with this refrigerant.
DO NOT use equipment certified for
R22 refrigerant only.
SAFETY PRECAUTIONS
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord.
For personal safety, this appliance must be
properly grounded.
DO NOT use an adapter plug with this
appliance.
The power cord of this appliance is equipped
with a 3-prong (grounding) plug which mates
with a standard 3-prong (grounding) wall outlet
to minimize the possibility of electric shock
hazard from this appliance.
Power cord includes a current interrupter device.
A test and reset button is provided on the plug
case. The device should be tested on a periodic
basis by first pressing the TEST button and
then the RESET button while plugged into the
outlet. If the TEST button does not trip or if the
RESET button will not stay engaged, discontinue
use of the air conditioner and contact a qualified
service technician.
Have the wall outlet and circuit checked by
a qualified electrician to make sure the outlet
is properly grounded.
Where a 2-prong wall outlet is encountered,
it is your personal responsibility and obligation to
have it replaced with a properly grounded
3-prong wall outlet.
The air conditioner should always be plugged
into its own individual electrical outlet which has
a voltage rating that matches the rating plate.
This provides the best performance and also
prevents overloading house wiring circuits which
could cause a fire hazard from overheated wires.
See the Installation Instructions, Electrical
Requirements section for specific electrical
connection requirements.
HOW TO CONNECT ELECTRICITY
3
GEAppliances.com
WARNING!
USE OF EXTENSION CORDS
READ AND FOLLOW THIS SAFETY INFORMATION
CAREFULLY
.
SAVE THESE INSTRUCTIONS
RISK OF FIRE. Could cause serious injury or
death.
DO NOT use an extension cord with this
Window Air Conditioner.
DO NOT use surge protectors or multi-outlet
adaptors with this Window Air Conditioner.
4
About the controls on the air conditioner.
Controls
FanFan
Remote Control
Delay timer Increase
Auto Fan on
Fan speed Increase
Unit power on/off
NOTE: The display always
shows the room temperature
except when setting the Set
temperature or the Delay timer.
Air Conditioner Controls
Light indicates the
delay timer is set.
Light indicates the unit
is in the temperature or
delay time Set mode.
Delay 1–24hr
Delay timer
Decrease
Mode select
Fan speed
Decrease
Temperature
set Increase
and Decrease
Features and appearance will vary.
Lights next to the touch pads on the air conditioner control panel indicate the selected settings.
Power Pad
Turns air conditioner on and off. When turned
on, the display will show the room temperature.
Display
Shows the room temperature or time remaining
on the Delay timer. Shows the Set temperature
while setting the temperature in Cool or Energy
Saver modes. The Set light will turn on while
setting.
Temp Increase /Decrease Pads
Use to set temperature when in Cool or Energy
Saver mode. The Set light will turn on while
setting.
Delay Timer Increase (+) /Decrease (–)
Pads
Each touch of the Increase / Decrease
pads on the unit or the Increase + / Decrease
pads on the remote control will set the delay
time when using the Delay 1–24hr timer. The
Set light will turn on while setting.
Fan Speed Pads
Use to set the fan speed to Low, Med, High
or Auto on the unit. NOTE: On the remote
control, use the fan speed Increase + /
Decrease pads to set the fan speeds to Low,
Med or High. Use the Auto pad to turn Auto
fan on.
Mode Pad
Use to set the air conditioner to Cool, Energy
Saver or Fan Only mode.
Delay Pads/Delay 1-24hr Pad
Delay ON—When the air conditioner is off, it can
be set to automatically come on in 1 to 24 hours
at its previous mode and fan settings.
Delay OFFWhen the air conditioner is on,
it can be set to automatically turn off in 1 to
24 hours.
How to set:
Press the Delay 1–24hr pad on the unit or the
Delay pad on the remote control. Each touch
of the Increase / Decreasepads on the
unit or the Increase + / Decrease pads on
the remote control will set the timer in 1-hour
intervals. The Set light will turn on while setting.
To review the remaining time on the Delay
1–24hr timer, press the Delay 1–24hr pad on
the unit or the Delay pad on the remote control.
Use the Increase / Decrease pads on the
unit or the Increase + / Decrease pads on the
remote control to set a new time if desired.
To cancel the timer, press the Delay 1–24hr pad
until the light on the Delay 1–24hr pad goes off.
Note: The default temperature reading on the display is degree Fahrenheit ( °F). To change the display to
degree Celcius (°C), press the Temp Increase and Temp Decrease buttons together and hold for 3
seconds. Repeat the process to change back to degree Fahrenheit (°F)
5
GEAppliances.com
In the case of a power outage or interruption, the
unit will automatically re-start in the settings last
used after the power is restored. If the Delay 1–24hr
feature was set, it will resume countdown. You may
need to set a new time if desired.
Power Outage Recovery Feature
Cool Mode
Use the Cool mode at Low, Med, High or Auto Fan
Speed for cooling. Use the Temperature Increase
/ Decrease pads to set the desired temperature
between 64°F and 86°F in 1°F increments.
An electronic thermostat is used to maintain the room
temperature. The compressor will cycle on
and off to keep the room at the set level of comfort.
Set the thermostat at a lower number and the indoor
air will become cooler. Set the thermostat at a higher
number and the indoor air will become warmer.
NOTE: If the air conditioner is off and is then turned on
while set to a Cool setting or if turned from a fan
setting to a Cool setting, it may take approximately
3 minutes for the compressor to start and cooling to
begin.
Cooling Descriptions
For Normal Cooling—Select the Cool mode and
High or Med fan with a middle set temperature.
For Maximum Cooling—Select the Cool mode
and High fan with a lower set temperature.
For Quieter and Nighttime Cooling—Select the
Cool mode and Low fan with a middle set
temperature.
Energy Saver Mode
Controls the fan.
ON—The fan will cycle on and off with the
compressor. This results in wider variations of room
temperature and humidity. Normally used when the
room is unoccupied. NOTE: The fan may continue to
run for a short time after the compressor cycles off.
OFF—The fan runs all the time, while the compressor
cycles on and off.
Fan Only Mode
Use the Fan Only Mode at Low, Med or High fan
speed to provide air circulation and filtering without
cooling. Since fan-only settings do not provide
cooling, a Set temperature cannot be entered. The
room temperature will appear
in the display.
NOTE: Auto Fan Speed cannot be used when in the
Fan Only Mode.
Set to Auto fan speed for the fan speed to
automatically set to the speed needed to provide
optimum comfort settings with the set temperature.
If the room needs more cooling, the fan speed
will automatically increase. If the room needs less
cooling, the fan speed will automatically decrease.
NOTE: Auto Fan Speed cannot be used when in the
Fan Only Mode.
Auto Fan Speed
Remote Control
n To ensure proper operation, aim the remote
control at the signal receiver on the air
conditioner.
n Make sure nothing is between the air conditioner
and the remote control that could block the
signal.
n The remote control signal has a range of
up to 20 feet.
n Make sure batteries are fresh and installed
correctly as indicated on the remote control.
n Remote contains a magnet allowing it to attach
to metal surfaces.
6
Air Direction
Use the lever to adjust the air direction left and right
only.
About the controls on the air conditioner
Additional important information.
Turn the air conditioner off and remove the plug from
the wall outlet before cleaning.
To clean, use water and a mild detergent. Do not use
bleach or abrasives.
Grille and Case
Care and cleaning of the air conditioner.
Outdoor Coils
The coils on the outdoor side of the air conditioner
should be checked regularly. If they are clogged with
dirt or soot, they may be professionally cleaned.
1
Remove the battery cover by sliding it according
to the arrow direction.
2
Insert new batteries, making sure that the (+)
and (–) of battery are installed correctly.
3
Reattach the cover by sliding it back
into position.
NOTES:
n Use 2 “AAA” (1.5 volt) alkaline batteries. Do not
use rechargeable batteries.
n Remove the batteries from the remote control if
the system is not going to be used for a long time.
n Do not mix old and new batteries. Do not mix
alkaline, standard (carbon-zinc) or rechargeable
(ni-cad, ni-mh, etc) batteries.
How to Insert the Batteries in the Remote Control
Air Filter
The air filter behind the front grille should be checked
and cleaned at least every 30 days or
more often if necessary.
To remove:
Open the inlet grille by pulling downward on the tabs
at the top upper corners of the inlet grille until the
grille is in a 45º position. Remove the filter.
Clean the filter with warm, soapy water. Rinse and let
the filter dry before replacing it. Do not clean the filter
in a dishwasher.
CAUTION: DO NOT operate the air
conditioner without a filter because dirt and lint will
clog it and reduce performance.
Tab Tab
BEFORE YOU BEGIN
Read these instructions completely
and carefully.
IMPORTANT Save these
instructions for local inspector’s use.
IMPORTANT Observe all
governing codes and ordinances.
•
Note to Installer – Be sure to leave these
instructions with the Consumer.
• Note to Consumer – Keep these instructions for
future reference.
• Skill level – Installation of this appliance requires
basic mechanical skills.
• Completion time
Approximately 1 hour
• We recommend that two people install
this product.
• Proper installation is the responsibility of the
installer.
• Product failure due to improper installation is not
covered under the Warranty.
• You MUST use all supplied parts and use proper
installation procedures as described in these
instructions when installing this air conditioner.
Questions? Call 800.GE.CARES (800.432.2737) or visit our Website at: GEAppliances.com
In Canada, call 1.800.561.3344 or visit www.GEAppliances.ca
Installation Air Conditioner
Instructions
Some models require a 115/120-volt AC,
60-Hz grounded outlet protected with a
15-amp time-delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the possibility
of electric shock hazard. If the wall outlet you plan to
use is only a 2-prong outlet, it is your responsibility to
have it replaced with a properly grounded 3-prong wall
outlet.
Some models require 230/208-volt AC,
protected with a time-delay fuse or circuit
breaker. These models should be installed on
their own single branch circuit for best
performance and to prevent overloading
house or apartment wiring circuits, which
could cause a possible fire hazard from
overheating wires.
ELECTRICAL REQUIREMENTS
CAUTION:
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord.
Do not change the plug on the power cord
of this air conditioner.
Aluminum house wiring may present special
problems—consult a qualified electrician.
TOOLS YOU WILL NEED
Phillips-head screwdriver
Ruler or tape measurePencil
Level
Scissors or knife
Flat-blade screwdriver
Power cord includes a current interrupter device. A
test and reset button is provided on the plug case. The
device should be tested on a periodic basis by first
pressing the TEST button and then the RESET button
while plugged into the outlet. If the TEST button does
not trip or if the RESET button will not stay engaged,
discontinue use of the air conditioner and contact a
qualified service technician.
7
8
Installation Instructions
Right
accordion
panel
Foam top
window gasket
Left
accordion
panel
Screw (6)
Window
sash seal
Air
conditioner
Window locking
bracket (1)
PARTS INCLUDED
(Appearance may vary)
Frame locking
bracket (2)
Installation Instructions
STORM WINDOW REQUIREMENTS
A storm window frame will not allow the air
conditioner to tilt toward the outside, and will keep it
from draining properly.
To adjust for this, attach a piece of wood to the sill.
WOOD PIECES
WIDTH: 2”
LENGTH: Long enough to fit inside the window
frame.
THICKNESS: To determine the thickness, place a
piece of wood on the sill to make it 1/2” higher than
the top of the storm window frame or the vinyl
frame.
Attach securely with nails or screws provided by the
installer.
WINDOW REQUIREMENTS
These instructions are for a standard double-hung
window. You will need to modify them for other types
of windows.
The air conditioner can be installed without the
accordion panels if needed to fit in a narrow
window. See the window opening dimensions.
All supporting parts must be secured
to firm wood, masonry or metal.
The electrical outlet must be within reach of the
power cord.
1
PREPARE THE AIR CONDITIONER
Hold the accordion panel in one hand and
gently pull back to free the open end.
Slide the free end of the accordion panel into
the side panel rails. Slide the panel down. Be
sure to leave enough space to slip the top
and bottom of the frame into the rails on the
cabinet.
NOTE: There is a right and a left accordion
panel. Be sure to use the proper panel for each
side.
Slide the left and right accordion panels into
the top and bottom mounting rails.
3
A
C
Top left
Top right
2
1/2higher
than storm
window
frame
Storm window
frame
Wood
Sill
1/2higher
than vinyl frame
(on some windows)
Vinyl frame
Top mounting rail
B
9
15 ½” min.
22 to 36
(With accordion panels)
Bottom mounting rail
Installation Instructions
5
A
B
2 Frame locking brackets
PREPARE THE WINDOW
Cut the window sash seal to the proper
length. Peel off the backing and attach the
seal to the underside of the window sash.
4
6
INSTALL SUPPORT BRACKET AND
FOAM TOP WINDOW GASKET
Cut the foam top window gasket to the window
width.
Stuff the foam
between the glass
and the window
to prevent air and
insects from getting
into the room.
NOTE: If the gasket supplied does not fit your
window, obtain appropriate material locally to
provide a proper installation seal.
A
CAUTION:
To prevent broken glass or
damage to windows, on
vinyl or other similarly
constructed windows,
attach the window locking
bracket to the window
side jamb with one screw.
B
C
Wood
Vinyl
3 Screws
C
10
INSTALL THE AIR CONDITIONER IN
THE WINDOW
Place the air conditioner on the sill with the
bottom mounting rail against its back edge.
Center it and close the window securely behind
the top mounting rail.
It should be level or slightly tilted to the outside.
Use a level; about a 1/3 bubble will be the correct
case slant to the outside.
Extend the left and right accordion panels to
the vertical window sashes and attach 3 screws
through the holes in the upper panels, as
appropriate.
Install the frame locking brackets between the
bottom of the accordion panel and the window
sill. Attach with 2 screws. NOTE: To prevent the
window sill from splitting, drive the pilot holes
before driving the screws.
1

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw General Electric AEM12 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van General Electric AEM12 in de taal/talen: Engels, Frans, Spaans als bijlage per email.

De handleiding is 2,3 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info