479852
2
Verklein
Vergroot
Pagina terug
1/9
Pagina verder
DESCRIPTION
The system Gemini 7201 is a compact alarm supplied with sensors and siren, which can be
installed on vehicles with 12Volt battery-negative to earth.
FUNCTIONS
GEMINI 7201.
- Compact alarm with dynamic code (Frequency 433.92 MHz ).
- Blinker and electronic siren.
- Negative control for supplementary siren.
- Electrical central door locking control (negative or positive) windows and electric sunroof (for
vehicles equipped with Pack-comfort system).
- Perimetric and volumetric protection (US and HF models).
- LED’s memory and wiring connections diagnosis.
- Remote controlled PANIC function.
He alarm systems are equipped with 2 codified transmitters (art. 7208E).
INSTALLATION INSTRUCTIONS (for the installer)
- To make universal the central door locking system it is necessary to use a 5056 module.
- Connect the power feed wire to the battery positive terminal and the earth directly to the
vehicle frame.
- Connect the alarm Green-Brown wire to the door pin-switch.
- Avoid routing connection wires next to interference sources (sparking plugs cables, high
voltage coil).
- The alarm must be installed in the engine compartment protected from water and with the
key lock switch turned to the top.
- If you install an ultrasonic module the ultrasonic heads must be positioned at the top of each
windscreen pillar and must be pointing at each opposite diagonal corner away from the facia
outlets.
DIP-SWITCHES PROGRAMMING TABLE
1 ON Current absorption sensor ON
1 OFF Current absorption sensor OFF
2 ON Closure control 6 seconds
2 OFF Closure control 1 second
3 ON Comfort control ON (25 seconds)
3 OFF Comfort control OFF
4 ON Diagnostics ON
4 OFF Diagnostics OFF (normal use)
5 ON
5 OFF
Do not use
6 ON Self-learning of a new active code
6 OFF Self-learning of a new excluded code (normal use)
ATTENTION : SET THE DIP-SWITCHES BEFORE TURNING THE EMERGENCY KEY TO ON.
FOLLOWING THE PRESENT RULES IT IS ADVISABLE TO SET THE DIP-SWITCH N. 1 TO OFF.
DIAGNOSTICS: (final check-up o f the installer or quick after sale checks).
The diagnostics function allows during the test or at the end of the installation to verify quickly the
correct working of the alarm system and the electrical connections of the vehicle plant.
DIAGNOSTICS INLET. With the emergency key to OFF, set the dip-switch N.4 to ON. The activation
of the diagnostics function is signalled by 4 acoustic/optical signalling while supplying the alarm
system. At the end of the signalling the module outlets (+A) and the engine immobilisation
activates; the LED lights fix.
In this condition it is possible to test each inlet and if the external connections and/or the internal
circuits of the device work correctly one audible tone or one-direction indicator lights flashing signal
each alarm triggering.
It is necessary to wait 1 second between each alarm input triggering. In the diagnostics modality
the transmitter 1 button does not work as arming/disarming button but it is used to verify the
transmitter’s working. An audible tone or one direction indicator lights flashing signals the correct
working.
The transmitter 2 button activates the Panic alarm. This modality allows testing the siren working
and the outlet of the additional siren with negative control.
To stop the Panic alarm it is necessary to press again on the button 2 of the transmitter (followed
by a neutral period of 5 seconds).
DIAGNOSTICS OUTLET.
1. Press on the transmitter 2 button to activate the panic function.
2. During the alarm signalling, pressing on the transmitter 1 button the system goes back to the
normal working.
ATTENTION! AT THE DIAGNOSTIC OUTLET SET THE DIP-SWITCH N.4 TO OFF.
WIRING CONNECTIONS
(disconnect the negative pole of the battery and only reconnect after the installation is complete)
FUNCTION WIRE COLOUR
Earth ðð BLACK initialled “M”
Battery positive ðð BLACK initialled “R”
Ignition live ðð YELLOW
Direction indicator lights ðð 2 x ORANGE
Door pin switch ðð GREEN-BROWN
Boot and bonnet switch ðð GREEN
Positive alarm armed ðð PINK
Sensors inlet ðð GREEN-BLACK
Outlet negative control for
additional siren
ðð YELLOW-BLACK
Central door locking ðð YELLOW-RED, YELLOW-GREY, RED-GREY
NOTE: in the wiring harness there are 2 connectors; connect the 4-pin connector to the
ultrasonic module and the 2 -pin connector to the LED.
WORKING DESCRIPTION
ALARM ARMING
Press on the transmitter 1 button. The arming is signalled by 1 direction indicator lights flashing
and one acoustic signal (can be excluded).
ALARM DISARMING
Press on the transmitter 1 button. The disarming is signalled by 3 direction indicator lights flashing
and 3 acoustic signalling (can be excluded); 5 direction indicator lights flashing and 5 audible tones
(can be excluded) if an alarm condition has occurred.
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Gemini 7201 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Gemini 7201 in de taal/talen: Engels als bijlage per email.

De handleiding is 1,66 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info