Instructions for Assembly and Use
DC2 ”S“
Electronic control for tubular drives
The DC2 ”S“ is a modern and safe alternative to conventional control gear. For ope-
ning or closing of the door the drive unit is activated through a handtransmitter
(radio control) or through a push-button on the housing.
After pushing of the push-button or the handtransmitter the door is triggered UP or
DOWN.
Technical Data:
Supply voltage 230 V AC 50 Hz
Output 2x relay contact, 5 A / 230 V
1x relay contact, 2 A / 230 V
1x supply Voltage 24V/50mA
Connections 1.5 mm
2
max.,
Ambient- -20 ˚C to +60 ˚C
temperature
geba GmbH is released of its obligations regarding guarantee and product liability if - without
prior permission - the unit has been modified, or if the installation is improper or not in accordance
with our instruction manual.
The installer has to take care that the EMC-regulations are respected.
GB
The most important characteristics of the DC2 ”S“ are:
➢ Simple operation, programming and assembly.
➢ Water-protected enclosure.
➢ A maximum of safety:
➢ The electronic decoder is separately installed in the protected area
➢ Nearly unlimited data security, even with power failure
➢ Direct connection to safety edge
➢ Rolling code transmitter
➢ High switching capacity for direct control of appliances
24V / 50 mA output for lphoto beam
Service display
The 4 most likely faults are indicated by the service display lamp by means of a
simple flashing code system as below:
1x flash safety edge defect
2x flash limit switch not reached
or defect
3x flash pre-limit switch defect
steady glow safety edge activated