1. GENERAL
1.1 Installation and servicing must be carried out by a
competent person in accordance with Gas Safety
(Installation and Use) Regulations 1998, the relevant
British Standards for Installation, appropriate Codes of
Practice and in accordance with the manufacturers
instructions. It is recommended that a CORGI registered
engineer be used for this purpose as they are approved
by the HSE under the above regulations.
1.2 This appliance is suitable for use in G.B. and I.E. using
Natural Gas at a supply pressure of 20mbar or LPG at a
supply pressure of 29mbar (Butane) or 37mbar (propane).
1.3 The installation shall also be completed in accordance with:
– The Building Regulations issued by The Department of
The Environment.
– The Building Standards (Scotland) Regulations issued by
the Scottish Development Department.
For Republic of Ireland, reference should be made to the
relevant standards governing installations (IS813:1996)
1.4 Read all these instructions before commencing installation.
1.5 This appliance must be installed in accordance with the
rules in force and only used in a sufficiently ventilated
space.
1.6 Ensure that curtains are not positioned above the stove, and
that there is at least a clearance of 300mm between the
sides of the stove and any curtains.
1.7 The manufacturer considers the full outer casing of this
stove to be a working surface. Therefore it will become hot
whilst in operation. A suitable guard is recommended to
protect young children, the aged and the infirm.
1.8 This stove must only be operated with the door secured
firmly in position. If any cracks appear in the glass the
appliance must not be used until the glass panel is replaced.
1.9 Do not attempt to burn rubbish in this stove.
1.10 Any combustible shelves or surrounding furniture must only
be fitted in accordance with the minimum dimensions
detailed in diagram 1.
1
AR1468
1.11 Contact a competent service engineer to carry out relevant
spillage checks etc. following home improvements carried
out after installation of this stove (e.g. the fitting of double
glazing).
1.12 In all correspondence, please quote the appliance type and
serial number which can be found on the databadge at the
rear of the stove.
1.13 This product is guaranteed for 2 years from the date of
installation, as set out in the terms and conditions of sale
between Gazco and your local Gazco dealer. Please consult
with your local Gazco dealer if you have any questions. In
all correspondence always quote the model No. and serial
No. Please ensure the commissioning checklist is
completed by your installer, as this is a requirement of
your Guarantee.
2. LIGHTING THE STOVE
2.1 Locate the control valve on the appliance. There are two
control knobs on the valve, the right-hand knob controls the
pilot ignition and the left-hand knob controls the main
burner.
2.2 If your appliance has already been upgraded to battery
remote control, please refer to the instructions provided with
the upgrade to operate the remote control. The following
instructions will work for either situation.
2
AR0914
2.3 Ensure that the left-hand control knob is pointing to off ( )
2.4 Ensure that the right-hand control knob is pointing to off ( ).
2.5 Press in the right-hand control knob and rotate it anti-
clockwise until a click is heard (keep pressing in) and the
knob is pointing to pilot ( ). The pilot should now light. If
the pilot has not lit, repeat the procedure until it does.
2.6 Keep the control knob pressed in for 10 seconds and then
release it, the pilot should stay alight. If the pilot goes out,
repeat the procedure until does.
2.7 If the pilot will not light after repeated attempts, contact the
retailer or installer from whom the appliance was purchased.
2.8 Turn the right-hand control to point to main burner ( ) .
The appliance can now be controlled using the left- hand
control knob.
2.9 Turn the left-hand control knob to point to low fire ( ) the
main burner will light on low. The burner can now be
controlled between low and high settings. Turn the control
knob anti-clockwise to increase the flame height and
clockwise to decrease the flame height.
THE YELLOW FLAMES WILL APPEAR WHEN THE FIRE
HAS GAINED SUFFICIENT HEAT - TYPICALLY 10 TO 20
MINUTES.
IF THE APPLIANCE IS EXTINGUISHED OR GOES OUT IN
USE, WAIT 3 MINUTES BEFORE ATTEMPTING TO
RELIGHT THE APPLIANCE.
4
USER INSTRUCTIONS
4

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Gazco F40 Avanti Conventional Coal bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Gazco F40 Avanti Conventional Coal in de taal/talen: Engels als bijlage per email.

De handleiding is 3.44 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info