8
INSTALLATION INSTRUCTIONS
TECHNICAL SPECIFICATION
COVERING THE FOLLOWING MODELS:
CERAMICA MANHATTAN – 8615LUC – P8615LUC
Model Gas Gas Working NOX Aeration Injector Gas Rate Input kW (Gross) Country
CAT. Type Pressure Class m3/h High Low
8615LUC I2H Natural 20 mbar 3 Ø 14.5 375 0.623 6.6 3.6 GB, IE
(G20) Gross Gross
P8615LUC I3P Propane 37 mbar 3 Ø 11.5 x 2 165 0.232 6.4 3.6 GB, IE
(G31) Gross Gross
Packing Checklist
Qty Description
1 Stove
1 Flue Blanking plate
1 Coal Retainer
1 Log set (5 logs)*
1 Ash Panel (2 sections)*
1 Fixing Kit Containing
1 Instruction Manual
1 Wood Screw
1 Rawplug
1 Box spanner
*Packed in appliance
A B C D E
ins mm ins mm ins mm ins mm ins mm
28 711 271/2700 163/4427 177/8453 53/4145
1
AR1620
Efficiency Class II
Flue Outlet Size 127mm (5”) Ø
Gas Inlet Connection Size 8mm Ø
Minimum Flue Specification T260 / N2 / 0 / D / 1
Maximum Flue Temperature 180°C