4
USER INSTRUCTIONS
1. GENERAL
1.1 Installation and servicing must be carried out by a
competent person in accordance with Gas Safety (Installation
and Use) Regulations 1998, the relevant British Standards for
Installation, appropriate Codes of Practice and in accordance
with the manufacturer’s instructions. It is recommended that
a CORGI registered engineer be used for this purpose as
they are approved by the HSE under the above regulations.
1.2 This appliance is suitable for use in G.B. and I.E. using
Natural Gas at a supply pressure of 20mbar or LPG at a
supply pressure of 29mbar (Butane) or 37mbar (Propane).
1.3 The installation shall also be completed in accordance with:
The Building Regulations issued by The Department of The
Environment.
The Building Standards (Scotland) Regulations issued by the
Scottish Development Department. For Republic of Ireland,
reference should be made to the relevant standards
governing installations (IS813:1996)
1.4 Read all these Instructions before commencing installation.
1.5 This appliance must be installed in accordance with the rules
in force and only used in a sufficiently ventilated space.
1.6 Ensure that curtains are not positioned above the stove, and
that there is at least a clearance of 300mm between the
sides of the stove and any curtains.
1.7 The manufacturer considers the full outer casing of this stove
to be a working surface. Therefore it will become hot whilst
in operation. A suitable guard is recommended to protect
young children, the aged and the infirm.
1.8 This stove must only be operated with the door secured
firmly in position. If any cracks appear in the glass the
appliance must not be used until the glass panel is replaced.
1.9 Do not attempt to burn rubbish in this stove.
1.10 Any combustible shelves or surrounding furniture must only
be fitted in accordance with the minimum dimensions
detailed in Diagram 1.
1.11 Contact a competent service engineer to carry out relevant
spillage checks etc. following home improvements carried
out after installation of this stove (e.g. the fitting of double
glazing).
1.12 In all correspondence, please quote the appliance type and
Serial Number which can be found on the databadge at the
rear of the stove.
1.13 This product is guaranteed for 2 years from the date of
installation, as set out in the terms and conditions of sale
between Gazco and your local Gazco dealer. Please consult
with your local Gazco dealer if you have any questions. In
all correspondence always quote the Model No. and Serial
No. Please ensure the commissioning checklist is completed
by your installer, as this is a requirement of your Guarantee.
2. LIGHTING THE STOVE
2.1 Locate the control valve on the appliance. There are two
control knobs on the valve, the right-hand knob controls the
pilot ignition and the left-hand knob controls the main
burner.
2.2 If your appliance has already been upgraded to battery
remote control, please refer to the instructions provided with
the upgrade to operate the remote control. The following
instructions will work for either situation.
2.3 Ensure that the left-hand control knob is pointing to off ( )
2.4 Ensure that the right-hand control knob is pointing to off ( ).
2.5 Press in the right-hand control knob and rotate it
anticlockwise until a click is heard (keep pressing in) and the
knob is pointing to pilot ( ). The pilot should now light. If
the pilot has not lit, repeat the procedure until it does.
2.6 Keep the control knob pressed in for 10 seconds and then
release it, the pilot should stay alight. If the pilot goes out,
repeat the procedure until it does.
2.7 If the pilot will not light after repeated attempts, contact the
retailer or installer from whom the appliance was purchased.
2.8 Turn the right-hand control to point to main burner ( ) .
The appliance can now be controlled using the left-hand
control knob.
2.9 Turn the left-hand control knob to point to low fire ( ) the
main burner will light on low. The burner can now be
controlled between low and high settings. Turn the control
knob anti-clockwise to increase the flame height and
clockwise to decrease the flame height.
THE YELLOW FLAMES WILL APPEAR WHEN THE
FIRE HAS GAINED SUFFICIENT HEAT -
TYPICALLY 10 TO 20 MINUTES.
IF THE APPLIANCE IS EXTINGUISHED OR GOES
OUT IN USE, WAIT 3 MINUTES BEFORE
ATTEMPTING TO RELIGHT THE APPLIANCE.
1
AR0509.2
AR0531b
2
AR0914