10
GB
The factory settings are restored.
vPress Menu-key and Man.-key simultaneously for 3 seconds.
All the LCD symbols are displayed for 2 seconds and the
display moves to the normal display.
•All the program data are set to zero.
•The manual watering period is set to 0:30 again.
•The time and day of the week are retained.
If no entry is made during programming for a period of more than
60 seconds, the normal display reappears. In this case all changes
made up till now will be applied.
When a sensor installed in the water computer registers damp
(OFF), the programmed watering is not carried out.
6. Putting Your Water Computer out of Operation
1. To preserve the battery, it should be removed (see
4. Initial Operation).
The programmes remain stored. If the battery is inserted
again in spring, only the time of day and the weekday must
be newly entered.
2. Store controller and valve unit in a dry place where they are
protected from frost.
The product must not be added to normal household waste. It
must be disposed of in line with local environmental regulations.
vImportant: Make sure that the unit is disposed of via your
municipal recycling collection centre.
vPlease return flat batteries to a GARDENA dealer or dispose
of them properly at your nearest recycling centre.
Only dispose of batteries when they are flat.
7. Maintenance
The filter Mshould be checked regularly and cleaned when
necessary.
1. Unscrew sleeve nut Gof the Water Computer by hand
from the tap thread (do not use pliers).
2. If necessary unscrew the adaptor H.
3. Remove filter Mfrom sleeve nut Gand clean.
4. Fit the Water Computer again (see 4. Putting Your Water
Computer into Operation
“Connecting Water Computer”
).
Reset:
Important information:
Storage /
Overwintering:
Disposal:
(in accordance with
Directive 2012/19/EU)
Disposing of flat batteries:
Clean filter :