16
GB
Frost-free storage
6. Trouble-Shooting
Problem Probable cause Remedy
Pump is running, Air cannot escape, since vOpen pressure line
but doesn’t deliver. pressure line is closed. (e.g. kinked pressure pipe).
Air locks in the suction base. vWait for max. 3 minutes
until the pump deaerates
automatically over the vent
valve. If necessary, switch
off and start it again.
Impeller clogged. vDisconnect plug and clean
impeller (see 5. Cleaning).
When starting the pump, vFill the pump over the
water height falls below the universal fitting 7with
min. water level. water.
Pump doesn’t start or Thermal overload switch has vDisconnect plug and clean
suddenly stops during switched the pump off due impeller (see 5. Cleaning).
to overheating. Observe max. media temper-
ature of 35 °C.
No power. vCheck fuses and electric
connections.
Dirt particles are jammed vDisconnect plug and clean
in the suction base. suction base (see 5. Clean-
ing).
Pump runs, but output Suction base is clogged. vDisconnect plug and clean
suddenly decreases. suction base (see 5. Clean-
ing).
Pump does not reach The suction base cover 0is vDisconnect plug and install
residual water height of 1 mm missing in the suction base. the suction base cover 0
during flat suction. (see 5. Cleaning).
Pump does not switch on or The pump is not upright. vPlace pump in an upright
off automatically when set position.
to automatic operation. The integral float switch 5vClean float switch (see
is sticking. 5. Cleaning).
Attention!
Repairs on electrical parts should only be done by our
GARDENA Service Centres.
If you have any problems with your Pump, please contact our Service.
7. Storage
Store the pump away from frost before the first frost sets in.
The device must not be added to the normal household waste,
it must be disposed of in accordance with local regulations.
Disposal:
(in accordance with