18
7.1 Technical data
Total rating: 2,3kW
Fuse: 10 A
Dimensions: B 288 x D 490 x H 190/260 mm
Pay attention to the data on the rating plate. The
appliance can be connected with a plug or it can
be connected permanently.
7.2 Important notes
The installing technician is responsible for the
correct functioning of the appliance at the time of
installation. He must instruct the user on how to
operate the appliance correctly on the basis of
the Operating Instructions, and the user must be
instructed on how to disconnect the appliance in
an emergency.
The appliance must only be connected by an
authorised specialist, paying attention to the
relevant regulations of the power supply companies
and the regional construction regulations.
The minimum distance from the trough base to the
nearest heat-sensitive parts is 10 mm.
The distance between the side and wooden built-in
furniture must be at least 200 mm.
During installation, pay attention to a minimum
clearance of 35 mm from the wall trim or 50 mm
from the wall (measured from the edge of the
appliance cutout).
Note: do not install the appliance directly next
to a deep fryer!
Possible damage, caused by failure to observe
these instructions cannot be recognised.
Connection type Y: if damaged, the mains cable
must be replaced by a special mains connecting
cable. The mains connecting cable must only be
connected by the manufacturer or the
manufacturer's authorised after-sales service.
The mains connecting cable must at least
correspond to the type H 05 VV-F.
A suction extractor must be installed if
suspended cupboards are installed over the steam
cooker because the steam might otherwise damage
built-in furniture.
The steam cooker may be installed in kitchen
combinations made of wood or similar combustible
materials without taking additional measures.
Pay attention to the “Important notes" (chapter 1).
Technical modifications reserved.
Electrical connection
The appliance must only be connected by an
authorised electrician, paying attention to all
relevant regulations.
You are advised to install an earthed socket for 10 A
or a junction box about 70 cm above the floor space
behind the appliance to that it is also accessible
after installtion of the appliance.
If, after installation, not all poles of the appliance
can be isolated from the mains by removing a plug,
an isolating device with a contact gap of at least
3 mm (e.g. a fuse) must be permanently installed.
7. Assembly instructions
TYPE: HLVK 230
VK 230-...
230-240 V AC 50/60Hz 2300 W
10 A