Technical data
Total connected load: 220-240 V AC, 16 A
Heating power:
Grill: 1 800W
Total output: 3 600W
Technical modifications without notice.
Installation notes
Pay attention to Chapter 1 (Important notes).
The appliance must only be connected by an
authorised specialist, paying attention to the
relevant regulations of the power supply companies
and the regional construction regulations.
The installing technician is responsible for the
correct functioning of the appliance at the time of
installation. He must instruct the user on how to
disconnect the appliance in an emergency.
We accept no liability for damage caused by failure
to comply with these instructions.
The appliance must always be disconnected from
the mains when being repaired or in an emergency.
To do this, remove the mains plug or switch off the
corresponding fuse.
Repairs and maintenance work must be carried out
by trained after-sales technicians.
Electrical connection rates and information on the
rating plate must agree with each other.
The wiring schematic that is placed on the outer
panel of the appliance shows the connection variant
again.
Do not use any extension leads!
The electrical safety of the appliance is guaranteed
only if the earthing system belonging to the
domestic installation is installed in accordance with
regulations.
The manufacturer is not liable for damage that
might arise as the result of improper or non-existent
earthing of the appliance.
You can optionally connect the appliance to
230 V 1N
~~
or 400 V 2N
~~
by way of a properly
installed socket or junction box.
If the appliance is connected to 230V 1N
~~
, a 16 A
fuse must be installed or, if it is connected to
400 V 2N
~~
, it must be fused with 2 x 10 A.
As standard, the appliance is designed for a rated
voltage 230V 1N
~~
and, in accordance with the
rating plate, it can be converted for connection to
400 V 2N
~~
. Insofar as necessary, the regulations of
the local electricity works must be observed.
On installation, an isolating device with a contact
gap of at least 3 mm (e.g. fuse or LS switch) must
be installed. Pay attention to fire protection
regulations in the proximity of heat-sensitive and
fire hazard substances.
When connecting the mains lead, you must at least
use a cable of the type H05 VV-F 3 x 1.5 mm
2
.
22