Original-Bedienungsanleitung FUXTEC FX-MSP2.2_de_en_fr_ita_rev09
38
Technical maintenance and storage
1. Technical supervision of the spray components
1) After spraying, clean all residues of the mixture from the chemical tank. Wash
the tank and all other parts.
2) After spraying or granule distribution, clean the spray extension and chemical
tank inside and outside.
3) After use, loosen the chemical tank cap.
4) After cleaning, let the machine run for 2-3 minutes.
2. Maintenance and care of the tank system
1) Do not leave the 2-stroke petrol mixture in the tank for a more extended time.
2) If a residual amount of the filling quantity remains in the fuel tank and
evaporator for a more extended period, the tank residues would stick/settle and
clog the lines, thus the machine will not run properly. If the device has been in
operation for a week, all fillings must be removed.
3. Maintenance of air filter and spark plug
1) Immediately after use, wash down the chemicals with a sponge. Otherwise,
the machine's performance could drop. Please pay special attention to this.
2) Please clean the air filter regularly.
3) Adequate distance of the spark plug is 06.-0.7mm; please check the space more
often; if it is too big or too small, determine the distance exactly as in Fig. 16.
Fig. 16
4. Storage for a longer time
1) External cleaning of the machine. Treat the outer
metal surface with anti-rust oil.