SP - 3
3 TRANSCEIVER MODULE
3.1 Frequency and Modulation 9410 MHz ±30MHz (X band), P0N
3.2 Peak Output Power M1824C-BB: 2.2 kW nominal,
M1834C-BB /1934C-BB: 4 kW nominal,
M1944C-BB: 6 kW nominal, M1954C: 12 kW nominal
3.3 Modulator FET Switching Method
3.4 Intermediate Frequency 60 MHz
3.5 Tuning Automatic or manual
3.6 Receiver Front End MIC (Microwave IC)
3.7 Bandwidth Tx pulselength 0.08 µs and 0.3 µs: 25 MHz
Tx pulselength 0.8 µs: 3 MHz
3.8 Duplexer Circulator with diode limiter
3.9 Warming up 90 to 180 s approx.
4 INTERFACE
4.1 Input Data IEC 61162-1 (NMEA 0183 Ver1.5/2.0)
Own ship’s position: GGA>RMC>RMA>GLL
Ship’s speed: RMC>RMA>VTG>VHW
Bearing (True): HDT>HDG
*1
>HDM
*1
>VHW
Bearing (Magnetic): HDM>HDG
*1
>HDT
*1
>VHW
Course: RMC>RMA>VTG
Water depth: DPT>DBT>DBS>DBK
Wind: MWV>VWT>VWR
Water Temperature: MTW
Time: ZDA
*1
: calculated by magnetic deviation
4.2 Output Data
Alarm signal 12 VDC, 100 mA or less
NMEA 0183 Ver1.5 GGA, GLL, RMA, RMC, GTD, VTG, ZDA (GPS data required)
RMB, WPL, BWC or BWR, APB, AAM, BOD, XTE, VHW,
MTW, DPT or DBT, DBS (ETR required),
TLL (L/L, Heading data required), TTM (ARPA required)
5 PLOTTER FUNCTION
5.1 Projection Mercator
5.2 Usable Area 85 latitude or below
5.3 Effective Area 211.2 x 158.4 mm
5.4 Display pixels 640 x 480 dots
5.5 Position Indication Latitude/longitude, Loran C LOP or DECCA LOP