OPTIONAL LOCKING FEATURES
The optional locking features are designed to discourage unauthorized removal of the battery or alarm. It is not necessary to activate the locks in
single-family households where unauthorized battery or alarm removal is not a concern.
These Smoke Alarms have two separate locking features: one to lock the battery compartment, and the other to lock the Smoke Alarm
to the mounting bracket. You can choose to use either feature independently, or use them both.
Tools you will need: • Needle-nose pliers or utility knife • Standard Flathead screwdriver.
Both locking features use locking pins, which are molded into the mounting bracket. Using needle nose pliers or a utility knife, remove one
or both pins from the mounting bracket, depending on how many locking features you want to use.
To permanently remove either lock insert a flathead screwdriver between the locking pin and the lock, and pry the pin out of the lock.
Locking Pin
TO LOCK THE BATTERY COMPARTMENT
(Model 9120B Only)
Do not lock the battery compartment until you have activated
the battery and tested the battery back-up.
1. Activate the battery back-up by removing
the “Pull to Activate Battery Back-Up” tab.
2. Push and hold test button until the alarm
sounds: 3 beeps, pause, 3 beeps, pause.
If the unit does not alarm during testing,
DO NOT lock the battery compartment!
Install a new battery and test again.
If the Smoke Alarm still does not alarm,
replace it immediately.
3. Using needle-nose pliers or a utility
knife, detach one locking pin from
the mounting bracket.
TO UNLOCK THE BATTERY COMPARTMENT
(Model 9120B Only)
Once the Smoke Alarm is installed, you must disconnect it from the AC power
before unlocking the battery compartment.
ELECTRICAL SHOCK HAZARD. Turn off the power to the area where the
Smoke Alarm is installed before removing it from the mounting bracket.
Failure to turn off the power first may result in serious electrical shock,
injury or death.
Always discharge the branch circuit before servicing an AC or AC/DC
Smoke Alarm. First, turn off the AC power at the circuit breaker or fuse
box. Next, remove the battery from Smoke Alarms with battery back-up.
Finally, press and hold the test button for 5-10 seconds to discharge the
branch circuit.
1. Remove the Smoke Alarm from the mounting
bracket. If the unit is locked to the bracket, see
the section “To Unlock the Mounting Bracket.”
2. Disconnect the power connector by gently prying
it away from the back of the Smoke Alarm.
3. Insert a flathead screwdriver under the head of
the locking pin, and gently pry it out of the bat-
tery compartment lock. (If you plan to relock the
battery compartment, save the locking pin.)
4. To relock the battery compartment, close the battery door and reinsert
locking pin in lock.
5. Reconnect the power connector to the back of the Smoke Alarm, reattach
the Smoke Alarm to the mounting bracket, and restore the power.
When replacing the battery, always test the Smoke Alarm before relocking the
battery compartment.
TO UNLOCK THE MOUNTING BRACKET
ELECTRICAL SHOCK HAZARD. Turn off the power to the area where the
Smoke Alarm is installed before removing it from the mounting bracket.
Failure to turn off the power first may result in serious electrical shock,
injury or death.
Always discharge the branch circuit before servicing an AC or AC/DC
Smoke Alarm. First, turn off the AC power at the circuit breaker or fuse
box. Next, remove the battery from Smoke Alarms with battery back-up.
Finally, press and hold the test button for 5-10 seconds to discharge the
branch circuit.
1. Insert a flathead screwdriver between the mounting bracket pin and the
mounting bracket.
2. Pry the Smoke Alarm away from the bracket by turning both the screw-
driver and the Smoke Alarm counterclockwise (left) at the same time.
TO LOCK THE MOUNTING BRACKET
1. Using needle-nose pliers or utility
knife, detach one locking pin from
mounting bracket.
2. Insert the locking pin into the
lock located on the base as
shown in the diagram.
3. When you attach the Smoke
Alarm to the mounting
bracket, the locking pin’s
head will fit into a notch on
the bracket.
4. Push the locking pin through the
black dot on the label on the back
of the Smoke Alarm.
4
4

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw First Alert 9120 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van First Alert 9120 in de taal/talen: Engels als bijlage per email.

De handleiding is 2.16 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info