User’s ManUal
Printed in Mexico
M08-0511-001 J1 09/14
IntrodUctIon
Thank you for choosing First Alert® for your Smoke Alarm needs. Y ou
have purchased a state-of-the-art Smoke Alarm designed to pr ovide
you with early warning of a fire. Please take the time to read this manual
and make the Smoke Alarm an integral part of your family’ s safety plan.
Key Features of the 0827 Smoke Alarm:
Tamper Resistant Lithium Battery Pack: Provides continuous power
for up to 10 years. Battery Pack cannot be removed and is not r eplace-
able.
Single Test/Silence Button: Allows you to test the Alarm or silence
nuisance alarms. T esting the Alarm assures you that the unit is function-
ing correctly and r eady to protect you and your family . The Alarm can
be silenced for up to 10 minutes in the event of a nuisance alarm.
End of Life warning: The Alarm will sound a “chirp” once per min-
ute when the Alarm reaches the end of its service life and needs to be
replaced.
Blinking Power Indicator: Confirms that the Smoke Alarm is receiving power .
© 2014 BRK Brands, Inc. All rights reserved. Distributed by
BRK Brands, Inc., 3901 Liberty Street Road, Aur ora, IL 60504-8122
Consumer Affairs: (800) 323-9005 • www .firstalert.com
FIre saFetY tIps
Follow safety rules and prevent hazar dous situations: 1) Use smoking
materials properly . Never smoke in bed. 2) Keep matches or lighters
away from childr en; 3) Store flammable materials in pr oper containers;
4) Keep electrical appliances in good condition and don’t overload elec-
trical circuits; 5) Keep stoves, barbecue grills, fir eplaces and chimneys
grease- and debris-fr ee; 6) Never leave anything cooking on the stove
unattended; 7) Keep portable heaters and open flames, like candles,
away from flammable materials; 8) Don’ t let rubbish accumulate.
Keep alarms clean, and test them weekly . Replace alarms immediately if
they are not working pr operly . Smoke Alarms that do not work cannot alert
you to a fire. Keep at least one working fir e extinguisher on every floor , and
an additional one in the kitchen. Have fire escape ladders or other r eliable
means of escape from an upper floor in case stairs ar e blocked.
BeFore YoU Inst all thIs sMoke alarM
IMPORT ANT! Read “Recommended Locations for Smoke Alarms”
and “Locations to Avoid for Smoke Alarms” befor e beginning. This
unit monitors the air , and when smoke reaches its sensing chamber ,
it alarms. It can give you more time to escape befor e fire spr eads.
This unit can ONL Y give an early warning of developing fires if it is
installed, maintained and located where smoke can r each it, and where
all residents can hear it, as described in this manual. This unit will not
sense gas, heat, or flame. It cannot prevent or extinguish fir es.
Understand The Differ ent T ype of Smoke Alarms
Battery powered or electrical? Dif ferent Smoke Alarms pr ovide
differ ent types of protection. See “About Smoke Alarms” for details.
Know Where T o Install Y our Smoke Alarms
Fire Safety Professionals recommend at least one Smoke Alarm on every
level of your home, in every bedroom, and in every bedr oom hallway
or separate sleeping area. See “Recommended Locations For Smoke
Alarms” and “Locations T o Avoid For Smoke Alarms” for details.
Know What Smoke Alarms Can and Can’t Do
A Smoke Alarm can help alert you to fire, giving you pr ecious time to
escape. It can only sound an alarm once smoke reaches the sensor . See
“Limitations of Smoke Alarms” for details.
Check Y our Local Building Codes
This Smoke Alarm is designed to be used in a typical single-family home.
It alone will not meet requir ements for boarding houses, apartment
buildings, hotels or motels. See “Special Compliance Considerations” for
details.
Weekl Y testIng
might accidentally damage or set fire to the unit or to your
for
Using the test button is the recommended way to test this
Smoke Alarm. Press and hold the test button on the cover of the unit
until the alarm sounds (the unit may continue to alarm for a few seconds
after you release the button).
hoW to Inst all thIs sMoke alarM
the p arts oF thIs sMoke alarM
FolloW these sIMple steps!
IF thIs sMoke alarM soUnds
respondIng to an alarM
you of a potentially dangerous situation that r equires your
Wha t to do In case oF FIre
• Don’t panic; stay calm. Follow your family escape plan.
• Get out of the house as quickly as possible. Don’t stop to
get dressed or collect anything.
• Feel doors with the back of your hand before opening them.
If a door is cool, open it slowly . Don’t open a hot door . Keep doors
and windows closed, unless you must escape through them.
• Cover your nose and mouth with a cloth (preferably damp).
T ake short, shallow breaths.
• Meet at your planned meeting place outside your home,
and do a head count to make sure everybody got out safely .
• Call the Fire Department as soon as possible fr om outside.
Give your address, then your name.
• Never go back inside a burning building for any reason.
• Contact your Fire Department for ideas on making your home safer .
Inst all the MoUntIng Bracket :
1. Place the bracket on the wall or ceiling
where you want to mount the alarm.
2. Hold the mounting bracket against the
ceiling (or wall) and trace around the
inside of the two keyhole slots.
3. Make a mark inside each outline for
the drill holes.
4. Put the unit where it won’ t get covered
with dust when you drill the mounting holes.
5. Using a 3/16-inch (5 mm) drill bit, drill a hole
through each
pencil mark.
6. Insert the plastic screw anchors (in the plastic bag
with screws) into the holes. T ap the screw anchors
gently with a hammer , if
necessary , until they are flush with the ceiling or
wall.
7. Line the mounting bracket up over the plastic screw
anchors.
8. Screw the mounting bracket to the ceiling or wall
through the mounting slots using the two scr ews
provided.
9. Tighten both screws all the way .
UsIng the sIlence Fea tUre
The Silence Feature can temporarily quiet an unwanted alarm for up
to 10 minutes. T o use this feature, press the “T est/Silence” button.
The Alarm remains functional. The LED will flash every 10 seconds
(for up to 10 minutes) to remind you the alarm has been silenced.
The flashing LED will stop when the unit returns to normal operation.
unit is dense enough to suggest a potentially dangerous
All First Alert®
Ionization technology is generally more sensitive than photoelectric
technology at detecting small particles, which tend to be produced
in greater amounts by flaming fir es, which consume combustible
materials rapidly and spread quickly . Sources of these fires may include
paper burning in a wastebasket, or a grease fire in the kitchen.
Photoelectric technology is generally more sensitive than ionization
technology at detecting large particles, which tend to be pr oduced
in greater amounts by smoldering fir es, which may smolder for
hours before bursting into flame. Sour ces of these fires may include
cigarettes burning in couches or bedding.
12 3
regUlar MaIntenance
This unit has been designed to be as maintenance free as possible, but
there ar e a few simple things you must do to keep it working properly .
• T est it at least once a week.
• Clean the Smoke Alarm at least once a month; gently vacuum the
outside of the Smoke Alarm using your household vacuum’ s soft
brush attachment. A can of clean compressed air (sold at computer
or office supply stor es) may also be used. Follow manufacturer
instructions for use. T est the Smoke Alarm. Never use water ,
cleaners or solvents since they may damage the unit.
• If the Smoke Alarm becomes contaminated by excessive dirt, dust
and/or grime, and cannot be cleaned to avoid unwanted alarms,
replace the unit immediately .
• Relocate the unit if it sounds frequent unwanted alarms. See
“Locations to Avoid For Smoke Alarms” for details.
When the battery pack becomes weak, the Smoke Alarm unit will
“chirp” about once a minute (the End of Life warning). This End of
Life warning should last for 7 days, but you should replace the Smoke
Alarm
immediately to continue your protection.
1. T est/Silence button
2. Power/alarm indicator LED
1. Mounting bracket
2. Mounting slots
3. Activation T ab
4. Deactivation T ab (located under label)
5. T ur n to attach to bracket
6 T ur n this way to remove fr om bracket
actIv a tIng the alarM:
attaching the Smoke Alarm to the
1. T ur n alarm upside down and pull out
activation tab as shown in diagram. If
you have trouble activating the unit, call consumer af fairs at
1-800-323-9005.
2. T est the Smoke Alarm. Press and hold the test button on the
cover of the unit until the alarm sounds (the unit may continue
to alarm for a few seconds after you release the button).
If the unit does not alarm
during testing, call Consumer Affairs for assistance.
a tt ach sMoke alarM to MoUntIng Bracket
1. Push the unit toward the bracket, and turn it clockwise until you feel it snap into place.
2. T est the unit again. Press the test button until the horn begins sounding. During
to perManentl Y deactIv a te the sMoke alarM
1. Once you deactivate this unit, it will not detect smoke or alarm.
It cannot be reactivated. Y ou must install a new unit to continue
your protection. Alarm will r esist mounting to the bracket after
deactivation.
2. Use a flathead screwdriver to scor e
label along dotted line.
3. Use thumb to pull deactivation tab
outward until tab snaps into place.
This will discharge the battery pack and
deactivate the unit.
4. Install a new Smoke Alarm immediately!
tools YoU WIll need:
• Pencil
• Drill with 3/16” (5 mm)
drill bit
• Standard flathead
screwdriver
• Hammer
lIMIted WarrantY
BRK Brands, Inc., (“BRK”) the maker of First Alert® brand products
warrants that for a period of ten years from the date of pur chase, this
product will be fr ee from defects in material and workmanship. BRK, at
its option, will repair or r eplace this product or any component of the
product found to be defective during the warranty period. Replacement
will be made with a new or remanufactur ed product or component. If
the product is no longer available, r eplacement may be made with a
similar product of equal or gr eater value. This is your exclusive warranty .
This warranty is valid for the original retail pur chaser from the date of
initial retail pur chase and is not transferable. Keep the original sales
receipt. Pr oof of purchase is r equired to obtain warranty performance.
BRK dealers, service centers, or retail stor es selling BRK products do
not have the right to alter , modify or any way change the terms and
conditions of this warranty .
This warranty does not cover normal wear of parts or damage resulting
from any of the following: negligent use or misuse of the pr oduct, use
on improper voltage or curr ent, use contrary to the operating instruc-
tions, disassembly , repair or alteration by anyone other than BRK or an
authorized service center . Further , the warranty does not cover Acts of
God, such as fire, flood, hurricanes or tornadoes.
BRK shall not be liable for any incidental or consequential damages
caused by the breach of any expr ess or implied warranty . Except to
the extent prohibited by applicable law , any implied warranty of
merchantability or fitness for a particular purpose is limited in duration
to the duration of the above warranty . Some states, provinces or
jurisdictions do not allow the exclusion or limitation of incidental or
consequential damages or limitations on how long an implied warranty
lasts, so the above limitations or exclusion may not apply to you. This
warranty gives you specific legal rights, and you may also have other
rights that vary from state to state or pr ovince to province.
If service is requir ed, do not return the product to your r etail-
er . In order to obtain warranty service, contact the Consumer Affairs
Division at 1-800-323-9005, 7:30 AM - 5:00 PM Central Standard Time,
Monday through Friday . T o assist us in serving you, please have the
model number and date of purchase available when calling.
BRK Brands, Inc., 25 Spur Drive, El Paso, TX 79906
This Smoke Alarm is designed to operate for 10 years, and is backed
by a 10-year limited warranty . The battery pack in this Smoke Alarm
is non-remo vable or non-replaceable. When it reaches the end of its
service life, you must rep lace the entire Smoke Alarm to continue your
protection.
IF YoU sUspect a proBleM
Smoke Alarms may not operate properly because of a dead or weak
battery pack, a build-up of dirt, dust or grease on the Smoke Alarm
cover , or installation in an improper location. Clean the Smoke Alarm as
described in “Regular Maintenance,” and test the Smoke Alarm again.
If it fails to test properly when you use the test button, or if the pr oblem
persists, replace the Smoke Alarm immediately .
If the Smoke Alarm is still not operating properly , and it is still under
warranty , please see “How to Obtain W arranty Service” in the Limited
W arranty below .
recoMMended loca tIons For
sMoke alarMs
The National Fire Pr otection Association (NFP A), recommends one
Smoke Alarm on every floor , in every sleeping area, and in every bed-
room. In new construction, the Smoke Alarms must be AC power ed
and interconnected. See “Agency Placement Recommendations” for
details. For additional coverage, it is recommended that you install a
Smoke Alarm in all rooms, halls, storage ar eas, finished attics, and
basements, where temperatur es normally remain between 40˚ F (4.4˚ C)
and 100˚ F (37.8˚ C). Make sure no door or other obstruction could keep
smoke from r eaching the Smoke Alarms.
• On every level of your home, including finished attics and basements.
• Inside every bedroom, especially if people sleep with the door partly
or completely closed.
• In the hall near every sleeping area. If your home has multiple
sleeping areas, install a unit in each. If a hall is over 40 feet (12
meters) long, install an alarm at each end.
• At the top of the first-to-second floor stairway , and at bottom of
basement stairway .
Specific requir ements for Smoke Alarm installation vary from state to
state and from r egion to region. Check with your local Fir e Department
for current r equirements in your ar ea. It is recommended AC or AC/DC
agencY placeMent recoMMenda tIons
NFP A 72 Chapter 29
“For your information, the National Fire Alarm and Signaling Code ,
NFP A 72, reads as follows:”
Where r equired by other governing laws, codes, or standards
for a specific type of occupancy , approved single and multiple-station
smoke alarms shall be installed as follows:
(1)*In all sleeping rooms and guest r ooms
(2)* Outside of each separate dwelling unit sleeping area, within 21 ft
(6.4 m) of any door to a sleeping room, with the distance measur ed
along a path of travel
(3) On every level of a dwelling unit, including basements
(4) On every level of a residential boar d and care occupancy (small
facility), including basements and excluding crawl spaces and
unfinished attics
(5)*In the living area(s) of a guest suite
(6) In the living area(s) of a r esidential board and car e occupancy
(small facility)
(Reprinted with permission from NFP A 72® , National Fire Alarm and
Signaling Code Copyright © 2010 National Fire Pr otection Association,
Quincy , MA 02269. This reprinted material is not the complete and
official position of the National Fir e Protection Association, on the
refer enced subject which is repr esented only by the standard in its
entirety), (National Fir e Alarm and Signaling Code® and NFP A 72® are
register ed trademarks of the National Fire Pr otection Association, Inc.,
Quincy , MA 02269).
Early warning detection is best achieved by the installation of fire
detection equipment in all rooms and ar eas of the household as follows:
A Smoke Alarm installed in each separate sleeping area (in the vicinity ,
but outside bedrooms), and Heat or Smoke Alarms in the living r ooms,
dining rooms, bedr ooms, kitchens, hallways, finished attics, furnace
rooms, closets, utility and storage r ooms, basements, and attached
garages.
loca tIons to avoId For sMoke alarMs
• Where combustion particles are pr oduced. Combustion particles
form when something burns. Areas to avoid include poorly ventilat-
ed kitchens, garages, and furnace rooms. Keep units at least 20 feet
(6 meters) from the sour ces of combustion particles (stove, furnace,
water heater , space heater) if possible. In areas where a 20-foot
(6 m) distance is not possible – in modular , mobile, or smaller
homes, for example – it is recommended the Smoke Alarm be
placed as far from these fuel-burning sources as possible. The
placement recommendations ar e intended to keep these Alarms at
a reasonable distance fr om a fuel-burning source, and thus reduce
“unwanted” alarms. Unwanted alarms can occur if a Smoke Alarm
is placed directly next to a fuel-burning source. V entilate these
areas as much as possible.
• In air streams near kitchens. Air curr ents can draw cooking smoke
into the sensing chamber of a Smoke Alarm near the kitchen.
• In very damp, humid or steamy areas, or dir ectly near bathrooms
with showers. Keep units at least 10 feet (3 meters) away from
showers, saunas, dishwashers, etc.
• Where the temperatur es are r egularly below 40˚ F (4.4˚ C) or above
100˚ F (37.8˚ C), including unheated buildings, outdoor rooms,
porches, or unfinished attics or basements.
• In very dusty , dirty , or greasy ar eas. Do not install a Smoke Alarm
directly over the stove or range. Clean a laundry r oom unit frequently
to keep it free of dust or lint.
• Near fresh air vents, ceiling fans, or in very drafty ar eas. Drafts can
blow smoke away from the unit, pr eventing it from r eaching the
sensing chamber .
• In insect infested areas. Insects can clog openings to the sensing
chamber and cause unwanted alarms.
• Less than 12 inches (305 mm) away from fluor escent lights.
Electrical “noise” can interfere with the sensor .
• In “dead air” spaces. “Dead air” spaces may prevent smoke fr om
reaching the Smoke Alarm.
“Dead air” spaces may prevent smoke fr om reaching the Smoke Alarm.
T o avoid dead air spaces, follow the installation recommendations below .
install Smoke Alarms as close to the center of the ceiling
as possible. If this is not possible, install the Smoke Alarm at least
4 inches (102 mm) from the wall or corner .
For wall mounting (if allowed by building codes), the top edge of Smoke
Alarms should be placed between 4 inches (102 mm) and 12 inches (305
mm) from the wall/ceiling line, below typical “dead air” spaces.
install the first Smoke
Alarm within 3 feet (0.9 meters) of the peak of the ceiling, measured
horizontally . Additional Smoke Alarms may be requir ed depending
on the length, angle, etc. of the ceiling’ s slope. Refer to NFP A 72 for
details on requir ements for sloped or peaked ceilings.
specIal coMplIance consIdera tIons
This Smoke Alarm is suitable for use in apartments, condominiums,
townhouses, hospitals, day care facilities, health car e facilities, boarding
houses, group homes and dormitories pr ovided a primary fire detection
system already exists to meet fir e detection requir ements in common
areas like lobbies, hallways, or por ches. Using this Smoke Alarm in
common areas may not pr ovide sufficient warning to all residents or
meet local fire pr otection ordinances/r egulations.
This Smoke Alarm alone is not a suitable substitute for complete fire
detection systems in places housing many people—like apartment
buildings, condominiums, hotels, motels, dormitories, hospitals, health
care facilities, nursing homes, day car e facilities, or group homes of
any kind. It is not a suitable substitute for complete fire detection
systems in warehouses, industrial facilities, commer cial buildings, and
special-purpose non-residential buildings which r equire special fir e
detection and alarm systems. Depending on the building codes in your
area, this Smoke Alarm may be used to pr ovide additional protection in
these facilities.
In new construction, most building codes requir e the use of AC or AC/
DC powered Smoke Alarms only . In existing construction, AC, AC/DC,
or DC powered Smoke Alarms can be used as specified by local build-
ing codes. Refer to NFP A 72 (National Fire Alarm and Signaling Code)
and NFP A 101 (Life Safety Code), local building codes, or consu lt your
Fire Department for detailed fir e protection r equirements in building s not
defined as “households”.
lIMIt a tIons oF sMoke alarMs
Smoke Alarms have played a key role in r educing deaths resulting fr om
home fires worldwide. However , like any warning device, Smoke Alarms
can only work if they are pr operly located, installed, and maintained, and
if smoke reaches them. They ar e not foolproof.
Practice the escape
plan at least twice a year , making sure that everyone is involved – from
kids to grandparents. Allow childr en to master fire escape planning and
practice before holding a fir e drill at night when they are sleeping.
If children or others do not r eadily waken to the sound of the smoke
alarm, or if there ar e infants or family members with mobility limitations,
make sure that someone is assigned to assist them in fir e drill and in
the event of an emergency . It is recommended that you hold a fire drill
while family members are sleeping in or der to determine their response
to the sound of the smoke alarm while sleeping and to determine
whether they may need assistance in the event of an emergency .
DC operated units can-
not work if the battery pack is missing, deactivated, or dead, or if the
battery pack was not activated correctly . AC units cannot work if the AC
power is cut off for any r eason (open fuse or circuit br eaker , failure along
a power line or at a power station, electrical fire that burns the electrical
wires, etc.). If you ar e concerned about the limitations of DC or AC
power , install both types of units.
Smoke Alarms cannot detect fires if the smoke does not reach
Smoke from fires in chimneys or walls, on roofs, or on
the other side of closed doors may not reach the sensing chamber
and set off the alarm. That is why one unit should be installed inside
each bedroom or sleeping ar ea—especially if bedroom or sleeping ar ea
doors are closed at night—and in the hallway between them.
Smoke Alarms may not detect fire on another floor or area of the
For example, a stand-alone unit on the second floor may not
detect smoke from a basement fir e until the fire spr eads. This may not
give you enough time to escape safely . That is why recommended
minimum protection is at least one unit in every sleeping ar ea, and
every bedroom on every level of your dwelling. Even with a unit on
every floor , stand-alone units may not provide as much protection as
interconnected units, especially if the fir e starts in a remote ar ea. Some
safety experts recommend installing inter connected AC powered units
with battery back-up (see “About Smoke Alarms”) or professional
fire detection systems, so if one unit senses smoke, all units alarm.
Interconnected units may pr ovide earlier warning than stand-alone
units since all units alarm when one detects smoke.
Though the alarm hor n in this unit
meets or exceeds current standar ds, it may not be heard if: 1) the unit
is located outside a closed or partially closed door , 2) residents recently
consumed alcohol or drugs, 3) the alarm is drowned out by noise fr om
stereo, TV , traffic, air conditioner or other appliances, 4) residents ar e
hearing impaired or sound sleepers. Special purpose units, like those
with visual and audible alarms, should be installed for hearing impaired
residents.
Like any electronic device, Smoke
Alarms are made of components that can wear out or fail at any time.
Y ou must test the unit weekly to ensure your continued protection.
Smoke Alarms cannot prevent or extinguish fir es. They are not a
substitute for property or life insurance.
The unit should be replaced
immediately if it is not operating properly . Y ou should always replace a
Smoke Alarm after 10 years from date of pur chase. Write the pur chase
date on the space provided on back of unit.
First Alert® is a register ed trademark of the First Alert T rust.
6
aBoUt sMoke alarMs
Battery or DC operated Smoke Alarms: Provide pr otection even
when electricity fails, provided the batteries or battery packs ar e fresh
and correctly installed or activated. Units ar e easy to install, and do not
requir e professional installation.
AC powered Smoke Alarms: Can be interconnected so if one unit
senses smoke, all units alarm. They do not operate if electricity fails.
will operate if electricity fails, provided
the batteries are fr esh and correctly installed. AC and AC/DC units
must be installed by a qualified electrician.
power systems: AC powered Smoke Alarms should only be operated
with true or pure sine wave inverters. Operating this Smoke Alarm with
most battery-powered UPS (uninterruptible power supply) pr oducts or
square wave or “quasi sine wave” inverters will damage the Alarm .
If you are not sur e about your inverter or UPS type, please consult with
the manufacturer to verify .
Continued...
ABOUT SMOKE ALARMS, Continued
Smoke Alarms for the hearing impaired: Special purpose Smoke
Alarms should be installed for the hearing impaired. They include a
visual alarm and an audible alarm horn, and meet the requirements of
the Americans With Disabilities Act. Can be interconnected so if one
unit senses smoke, all units alarm.
unless the
combination has been evaluated and found suitable for that purpose.
All these Smoke Alarms are designed to pr ovide early warning of fires if
located, installed and cared for as described in the user’ s manual, and if
smoke reaches them. If you ar e unsure which type of unit to install, r efer
to Chapter 2 of the National Fire Pr otection Association (NFP A) Standard
72 (National Fire Alarm and Signaling Code) and NFP A 101 (Life Safety
Code). National Fir e Protection Association, One Batterymarch Park,
Quincy , MA 02269-9101. Local building codes may also requir e specific
units in new construction or in differ ent areas of the home.
BEDROOM
BEDROOM HALL
LIVING ROOM KITCHEN
FINISHED BASEMENT
REQUIRED TO MEET
NFP A RECOMMENDA TIONS
RECOMMENDED FOR
ADDITIONAL PROTECTION
BEDROOM
BEDROOM
KITCHEN
LIVING ROOM
DINING ROOM
MUL TI-STOR Y RESIDENCE
SINGLE-STOR Y RESIDENCE, A PA R TMENT ,
MOBILE HOME
KEY :
EXISTING HOMES
SMOKE ALARMS WITH SILENCE
FEA TURES RECOMMENDED FOR
ADDITIONAL PROTECTION
BEDROOM
BEDROOM HALL
LIVING ROOM KITCHEN
FINISHED BASEMENT
BEDROOM
BEDROOM LIVING ROOM
DINING ROOM
MUL TI-STORY RESIDENCE
SINGLE-STORY RESIDENCE, APA RTMENT ,
MOBILE HOME
EXISTING HOMES
KITCHEN
REQUIRED TO
MEET NFP A
RECOMMENDA TIONS
RECOMMENDED
FOR ADDITIONAL
PROTECTION
KEY : SMOKE ALARMS WITH SILENCE
FEA TURES RECOMMENDED FOR
ADDITIONAL PROTECTION
INTERCONNECTED AC OR
AC/DC SMOKE ALARMS
BEDROOM
BEDROOM HALL
LIVING ROOM KITCHEN
FINISHED BASEMENT
REQUIRED TO MEET
NFP A RECOMMENDA TIONS
RECOMMENDED FOR
ADDITIONAL PROTECTION
BEDROOM
BEDROOM LIVING ROOM
DINING ROOM
MUL TI-STOR Y RESIDENCE
SINGLE-STOR Y RESIDENCE, A PA R TMENT ,
MOBILE HOME
KEY :
NEW CONSTRUCTION
SMOKE ALARMS WITH SILENCE
FEA TURES RECOMMENDED FOR
ADDITIONAL PROTECTION
KITCHEN
INTERCONNECTED
AC OR AC/DC
SMOKE ALARMS
BEDROOM
BEDROOM HALL
LIVING ROOM KITCHEN
FINISHED BASEMENT
REQUIRED TO
MEET NFP A
RECOMMENDA TIONS
RECOMMENDED
FOR ADDITIONAL
PROTECTION
BEDROOM
BEDROOM LIVING ROOM
DINING ROOM
MUL TI-STORY RESIDENCE
SINGLE-STORY RESIDENCE, APA RTMENT ,
MOBILE HOME
KEY :
NEW CONSTRUCTION
SMOKE ALARMS
WITH SILENCE
FEA TURES
RECOMMENDED
FOR ADDITIONAL
PROTECTION
KITCHEN
Printed in Mexico M08-0511-001 J1 09/14
Date Purchased: _______________________________
Date Installed: ___________/____________Month/Y ear
Replacement Date: ___________/____________Month/Y ear
This user’ s manual contains
important information about
your Smoke Alarm’ s operation.
If you are installing this Smoke
Alarm for use by others, you
must leave this manual—or a
copy of it—with the end user .
Model 0827
CONFORMS TO
UL STD 217
to Unlock the MoUntIng Bracket
1. Insert a flathead screwdriver between the
mounting bracket pin and the mounting
bracket.
2. Pry the Smoke Alarm away from the bracket by turning both the
screwdriver and the Smoke Alarm counter clockwise (left) at the
same time.
to lock the MoUntIng Bracket
1. Using needle-nose pliers, detach one locking
pin from mounting bracket.
2. Insert locking pin into notch on base of alarm.
3. Attach Smoke Alarm to mounting bracket.
optIonal lockIng Fea tUre
Tools you will need: • Needle-nose pliers or utility knife • Standard Flathead scr ewdriver .
This locking feature uses locking pins, which ar e molded into the mounting bracket. Using needle nose pliers or a utility knife,
remove one pin fr om the mounting bracket.
4
sMoke alarM WIth ten-Year
non-replaceaBle lIthIUM Ba tterY p ack
and end oF lIFe notIFIca tIon Fea tUre