1C.81
WALL-MOUNTED TOUCH SCREEN 7 DAY
PROGRAMMABLE THERMOSTAT
CONTENTS
1
TECHNICAL CHARACTERISTICS ....................................................................... page 2
INSTALLATION ......................................................................................................... page 3
CONNECTION DIAGRAM ..................................................................................... page 4
BATTERY ..................................................................................................................... page 5
FIRST TIME USAGE ................................................................................................. page 6
DESCRIPTION OF KEYS ........................................................................................page 7
DESCRIPTION OF SYMBOLS .............................................................................. page 8
SETTING TIME AND DATE ................................................................................... page 9
MANUAL SETTINGS ............................................................................................... page 11
DISPLAY LOCK .......................................................................................................... page 11
PROGRAMMABLE THERMOSTAT LOCK (with PIN) .................................. page 12
SETTING TEMPERATURE ..................................................................................... page 14
PROGRAMMING ...................................................................................................... page 15
TIMED MANUAL MODE (Vacation) ................................................................. page 18
PARTY FUNCTION................................................................................................... page 20
FROST PROTECTION FUNCTION ...................................................................... page 21
DELAYED START ...................................................................................................... page 22
ADVANCED MENU .................................................................................................. page 23
ENERGY SAVING ..................................................................................................... page 29
SUPERVISOR FUNCTION ..................................................................................... page 32
CALIBRATION ........................................................................................................... page 35
NFC FUNCTION ........................................................................................................ page 36
TECHNICAL CHARACTERISTICS
Power: 2 x 1.5 V AAA alkaline batteries
Settable temperature range - WINTER: (+5…+37)°C
Settable temperature range - SUMMER: (+5…+37)°C
Settable temperature range - FROST PROTECTION: (+2…+8)°C
Temperature differential ΔT: (0.1…0.9)°C
Supervisor: Yes
Calibration: Yes
Resolution: 0.1°C
Tolerance: +/–0.5°C
Display: Touch screen
Backlight: Yes
Buzzer: Yes, for audible key feedback and function signals
Minimum time interval for programming: 30 minutes
Daylight saving time: User selectable automatic time adjustment function
Programmable thermostat lock: Yes, with PIN code
NFC: Yes
Output: 5 A 250 V AC SPDT relay (potential free contact)
Installation: Wall mounted
Protection rating: IP20
ADDITIONAL NOTES
The programmable thermostat produces three different audible signals:
- SHORT BEEP: When a button is pressed
- 3 LONG BEEPS: To confirm a saved parameter
- TRILL SOUND: Error
2
INSTALLATION
SAFETY INSTRUCTIONS
Electrical equipment must only be installed and assembled by expert
personnel.
Before connecting the programmable thermostat, ensure that all associated
utilities (pumps, valves, boiler etc.) are not connected to the supply and that
the load is within the ratings marked on the thermostat.
LOCATION
Install the programmable thermostat approximately 1.5 m above the floor,
and away from sources of heat (radiators, sunlight, cookers) and from doors
and windows.
CLEANING
Clean with a damp cloth only.
IMPORTANT
Do not overtighten the screws when installing, as this may warp the base
and compromise the functions of the touch screen.
3
4
CONNECTION DIAGRAM
5
Fit the batteries in the compartment, ensuring that the polarities are correct
as indicated.
IMPORTANT
- Fitting the batteries with the wrong polarity may damage the
programmable thermostat
- If battery charge drops below the minimum permissible level, the
programmable thermostat switches to OFF state and the relay contact
opens
- Remove the batteries if the programmable thermostat is not used for a
prolonged period of time
The programmable thermostat has the following three different low battery
warning modes:
- Low battery icon displayed STEADY: the functionality of the
programmable thermostat will soon be compromised
- Low battery icon
FLASHING: programmable thermostat requires
imminent battery replacement
- Messages flashing in alternation, programmable thermostat
switches to OFF state and the relay contact opens
NOTE
The correct date and time settings are maintained if the batteries are removed
and replaced within one minute with the low battery icon displaying STEADY.
BATTERY
6
FIRST TIME USAGE
After fitting the batteries, the display shows all the icons and the software
version for a few seconds, and then prompts the user to set the time and
date. Use the
keys to modify the value and press
OK
to confirm.
The main screen is then displayed.
BA
C
D E
F
L
I
H G
A ON/OFF
B Active icons
= air conditioning ON
= heating ON
C Temperature in °C
D Access programming mode
E Set time and date
F Day of week (indicated as a number from 1 to 7)
G Lock/unlock display or thermostat
H Time/temperature profile
I MANUAL mode ON/OFF
L Set temperature levels
NOTE
Touch the centre of the display to view the time and switch on the backlight.
7
DESCRIPTION OF KEYS
Programmable thermostat ON/OFF
T
Setting the 3 temperature levels
+
30 minute delay key (if function is enable in advanced menu)
Activate MANUAL mode. Press and hold for 3 sec. to programme
MANUAL TIMER MODE (vacation)
PRG
Access programming menu
Press and hold for 3 seconds to activate PARTY FUNCTION
Press and hold to activate or deactivate display lock
Set time and date
S
E
T
Press and hold for 3 seconds to access the advanced menu
Increase
Decrease
OK
Confirm
Go back to previous setting
Press and hold for 3 seconds to exit function
S
E
T
Go back to previous setting. Press and hold for 3 seconds to exit
advanced menu
8
DESCRIPTION OF SYMBOLS
Indicates if TIME and DATE setting mode is active of if current time is
displayed
Heating ON (in WINTER mode)
Air conditioning ON (in SUMMER mode)
Frost protection mode active
Data transfer
Shows setting limits in supervisor menu
Low batteries
+30
Start delayed by 30 minutes
°C
Unit of measurement (degrees celsius)
∆T
Temperature differential
Locked display or thermostat
012
24 hour time/temperature profile
1 2 3 4 5 6 7
Days of week
1 2 3 4 5 6 7
Days of week selected
9
Press to set the time and date.
The following values are shown in the order indicated:
HOURS / MINUTES / DATE / MONTH / YEAR
Use the
or keys to modify the flashing values.
Press
OK
to confirm and move to the next screen.
Press to go back or exit the menu.
EXAMPLE
Press
.
The HOURS value flashes.
Use the or buttons to set the correct hours value.
Press
OK
to confirm the hours value entered and set the MINUTES value
Press
OK
to confirm the minutes value entered.
Now set the DATE
SET TIME AND DATE
10
Press
OK
to confirm the DATE value and set the MONTH
Press
OK
to confirm the MONTH value and set the last two figures of the
YEAR
Press
OK
to confirm and exit the TIME / DATE setting menu.
The main screen is displayed.
NOTES
- The thermostat has approximately 1 minute of reserve power after the
batteries are removed.
After this period, the time, date and year settings are lost.
- Once the date is set, the correct number for the day of the week is set
automatically according to an internal calendar
- Press
to go back to the previous step
- Press and hold
for more than 3 seconds to return to the main screen
and save all values confirmed previously by pressing
OK
11
From the main screen, press .
The manual mode temperature value set previously is displayed.
To modify the setting, press to increase or to decrease the value.
Press to exit this mode.
NOTE
The current temperature reading is displayed if there is no user input for 3
seconds.
This function locks the display to prevent accidental changes to the settings
caused by unintentionally touching the screen.
Press and hold the button
to activate the function.
The icon appears on the display and the unit sounds 3 beeps to confirm
activation.
Press and hold for 3 seconds to deactivate the function
NOTE
The PIN set in the advanced LOCK menu must be
for the DISPLAY
LOCK function to be available (see page 28)
MANUAL SETTINGS
DISPLAY LOCK
12
This advanced function may be used to lock the thermostat. To activate the
function, set a 3 figure PIN code, which will be requested each time the user
wishes to lock or unlock the thermostat.
To set the PIN:
- Turn the thermostat off by pressing
- Press and hold
S
E
T
for 3 seconds to access the ADVANCED MENU
- Press button
OK
repeatedly to access the screen for entering the
desired PIN code
Use the and keys to set the desired PIN code number, then press
OK
to confirm. After setting the PIN, exit the advanced menu by pressing
OK
repeatedly or by pressing and holding
S
E
T
for 3 seconds, until the
beep is heard confirming that the PIN code has been saved correctly. When
the thermostat is switched on again, the main screen is displayed.
To activate the thermostat lock with PIN code, press and hold for 3
seconds. The following screen is displayed
PROGRAMMABLE THERMOSTAT LOCK (with PIN)
13
Use the and keys to enter the PIN number set previously in the
advanced menu, then press
OK
. The unit beeps 3 times to confirm that the
thermostat is locked and the following screen is displayed
To unlock the thermostat, press and hold
for 3 seconds.
The value is displayed.
Enter the PIN number and press
OK
to confirm.
The unit beeps 3 times to confirm that the thermostat is unlocked.
IMPORTANT
After three failed unlock attempts, no further PIN entry attempts may be
made for 20 seconds.
The message
is displayed.
NOTE
The display lock remains active even if the batteries of the thermostat are
removed and refitted.
Enter the emergency unlock code 513 if you have forgotten the PIN.
After unlocking the unit with the emergency unlock code 513, it is strongly
recommended to access the advanced menu and check and/or modify the
user-defined PIN set previously.
14
Used to set the three 3 temperature levels
(LOW-NIGHT-COMFORT).
Press
T
.
The first level value flashes. Set the desired LOW temperature value using
and .
Press
T
.
The second level value flashes. Set the desired NIGHT temperature value
using
and .
Press
T
.
The third level value flashes. Set the desired COMFORT temperature value
using
and
.
Press
T
to return to the main screen.
NOTE
The temperature level sequence is reversed for SUMMER mode.
i.e. The third level represents the lowest temperature.
SET TEMPERATURE
15
Press
PRG
to access the programming menu.
PROGRAMMING DAY / S
The day value 1(Monday) flashes.
Press or to change the day selection.
Select the desired day/s (e.g. 2, 3 and 4) with
OK
.
The selected days are highlighted against a black background.
Press on the profile to programme hours/temperatures.
PROGRAMMING INDIVIDUAL HOURLY SETPOINT TEMPERATURES FOR
24 HOUR PERIOD
The HOUR bar 0 flashes on the hours/temperature graph.
Use
and to select the temperature level.
Press
OK
to confirm and move to the next hour.
Repeat the same procedure for each hour.
NOTE Press to go back to the previous setting.
Press and hold the button for 3 seconds to exit programming mode and
save all settings confirmed previously by pressing
OK
.
PROGRAMMING
16
Once the temperatures are set for all 24 hours, the unit beeps three times to
confirm that the settings have been saved.
Only the remaining days are now displayed.
Now programme the remaining days, following the procedure described
above, or press to exit the menu.
The main screen is displayed.
NOTE
- Press and hold
for 3 sec. at any time to exit programming mode and
return to the main screen. All parameters confirmed previously by pressing
OK
are saved.
- To review the settings programmed for a specific day, press
PRG
in the
main menu and scroll between 1 and 7 with the arrow keys. Selecting a day
displays the respective profile programmed
- If the DELAYED START function is enabled in the advanced menu, the
button
+
is displayed, which may be used to delay the start of the
selected hour period by 30 minutes (see pages 22-30).
17
COPY FUNCTION
Press
PRG
to access the programming menu.
Day 1(Monday) flashes. Press or to change the selection.
For example, to copy the programme settings for day 2 into days 3 and 4,
select the days by pressing
OK
, selecting the day you want to copy (in this
case 2) first.
The selected days are highlighted against a black background.
Now press the time/temperature profile.
The first hour bar in the profile flashes.
Now press and hold for 3 seconds.
The unit beeps three times to confirm that the programme has been copied.
This function may be used to maintain a temperature value for a period of
time set by the user.
Once the set period of time has elapsed, the unit returns to the main screen.
From the main screen,
press and hold for 3 seconds.
Use the and keys to set the hour value of the time at which the
function will end.
Press
OK
to confirm, then set the minute value with the same procedure.
Now follow the same procedure to set
the date
the month
18
TIMED MANUAL MODE (vacation)
and the year
After pressing
OK
to confirm, use the
and
buttons to set the
desired temperature.
After setting the temperature and pressing OK to confirm.
The thermostat starts operating in timed manual mode, and a cycling
animated graphic is shown on the right hand side of the display to indicate
that the function is active
NOTE
The display shows the measured temperature, not the set temperature,
when this function is active. To view or modify the set time, press
. Then
press
OK
repeatedly to reach the screen with the value you want to modify.
Use the and buttons to modify, then press
OK
to confirm and
exit the menu.
Press
to deactivate the function while it is still active.
The main screen is displayed.
19
This function may be used to temporarily modify the set temperatures.
From the main screen, press and hold
PRG
for 3 seconds
The display shows the profile for the current day, with the current hour bar
flashing (hour bar 8 in this example).
Use
and
to modify the temperature.
Press
OK
to confirm and move sequentially onto the next bar to the right,
to set the other hours in the day, or press
to go back to the previous
value.
After modifying as desired, simply press no other keys to activate the
programme.
The function starts after a few moments, with a cycling animated graphic
shown on the display to indicate that the function is active.
Only the modified hour bars are displayed while the function is active.
NOTE
The modification is only effective for up to 24 hours, after which the original
programme is restored.
The main screen is displayed again once the function ends.
Press
at any time to exit the function. To view or modify the profile,
simply press
PRG
and repeat the modification procedure described
previously.
PARTY FUNCTION
20
21
The frost protection function is active when the thermostat is set to WINTER
mode and is off.
This function protects the system against damage caused by very low
temperatures.
When the set temperature threshold is reached, the function is activated and
the icons
appear on the display.
Press the ON key at any time to turn the thermostat on and display the
main screen.
FROST PROTECTION FUNCTION
This function may be used to delay start by 30 minutes after the activation
time indicated by the hour bar.
To activate the function, access the advanced menu and enable delayed start
(see page 30).
From the main screen, press
PRG
. Select the day or days with
, and
press
OK
to confirm.
Highlight the desired hour and press
+
to delay start by 30 minutes.
The symbol '+30' is displayed for the selected hour.
The symbol '+30' is displayed while the thermostat is operating normally.
Press and hold for 3 seconds to exit programming mode.
The unit beeps 3 times to confirm that the settings have been saved.
22
DELAYED START
The advanced menu may be used to personalise the setup of the thermostat.
1 - SUMMER – WINTER MODE
2 - FROST PROTECTION FUNCTION
3 - TEMPERATURE DIFFERENTIAL
4 - PUMP ANTI-SEIZE FUNCTION
5 - DAYLIGHT SAVING SETTINGS
6 - PROGRAMMABLE THERMOSTAT LOCK (with PIN)
7 - ENERGY SAVING E1
8 - ENERGY SAVING E2
9 - DELAYED START
10 - RESET
To enter the advanced menu, press
from the main screen and switch
off the thermostat.
Press and hold
S
E
T
for 3 seconds.
1 - SUMMER – WINTER MODE
One of the following screens is displayed
The icon indicates winter mode (heating), while the icon indicates
summer mode (cooling). Use the and keys to set the desired
mode. Press
OK
to confirm and go to the next menu.
To exit the menu, press
S
E
T
or press
OK
repeatedly until the OFF screen is
displayed.
If any settings were modified, the unit beeps 3 times to confirm that the
changes have been saved.
23
ADVANCED MENU
24
2 - FROST PROTECTION FUNCTION
After setting Summer or Winter mode, press
OK
to view the frost protection
function screen.
Set the desired temperature within a range from 2°C to 8°C with the
and keys.
Press
OK
to confirm and go to the next menu.
Press
S
E
T
to go back to the previous menu, or exit the advanced menu by
pressing and holding
S
E
T
for 3 seconds or pressing
OK
repeatedly until
the OFF screen is displayed. If any settings were modified, the unit beeps 3
times to confirm that the changes have been saved.
3 - TEMPERATURE DIFFERENTIAL
After confirming the desired frost protection temperature with
OK
, the
following screen is displayed.
The temperature differential setting is used to set the thermostat correctly
for the type of system to be controlled.
Set the temperature differential within a range from 0.1°C to 0.9°C with the
and keys.
Press
OK
to confirm and go to the next menu.
Press
S
E
T
to go back to the previous menu, or exit the advanced menu by
pressing and holding
S
E
T
for 3 seconds or pressing
OK
repeatedly until
the OFF screen is displayed. If any settings were modified, the unit beeps 3
times to confirm that the changes have been saved.
4 - PUMP ANTI-SEIZE FUNCTION
After programming the temperature differential, press
OK
to display the
following screen
(anti-seize function off)
The pump anti-seize function makes the thermostat function as an on-off
timer. With a value between 1 and 99 HOURS set for the function, the
programmable thermostat closes the relay contact for a period of 30
seconds at each time interval set.
Example:
If a value of 48 (48 hours = 2 days) is set with the and keys and
confirmed by pressing
OK
, the thermostat closes the relay contact for 30
seconds once every 2 days.
When the function is enabled in the menu, the timer starts from the last time
the relay contact was switched off.
Press
S
E
T
to go back to the previous menu, or exit the advanced menu by
pressing and holding
S
E
T
for 3 seconds or pressing
OK
repeatedly until
the OFF screen is displayed.
If any settings were modified, the unit beeps 3 times to confirm that the
changes have been saved.
25
26
5 - DAYLIGHT SAVING SETTINGS
This function configures the thermostat to:
- change the clock for daylight saving time automatically (dat1)
- not change the clock for daylight saving time automatically (dat0)
- set day “1”, for example, as Monday or Sunday (dat2)
The following screen is displayed:
By pressing
OK
to confirm, the thermostat changes the clock for daylight
saving time automatically.
Set this value to
(zero) with the and keys to disable automatic
clock adjustment for daylight saving time and change the clock manually.
Set the value to 2 with the and keys to enter the day of the week
manually with the TIME and DATE keys.
Press
OK
to confirm and go to the next menu.
Then exit the advanced menu and modify the day 1 setting as follows:
press and hold
S
E
T
for 3 seconds (the OFF screen is displayed).
Press to turn the thermostat on.
Press to view the hours and minutes and then the week bar.
Use the and keys to select the correct day.
For example:
If the current day is Wednesday and you want to set Sunday as day 1 (start
of week), select 4 on the display and press
OK
to confirm.
NOTE
Only one of the three settings may be configured. If this parameter is set to 1
or 0, the first day of the week is set as Monday by default.
If the parameter is set to 2, the first day of the week may be selected but the
clock will not be adjusted automatically for daylight saving time.
27
28
6 - LOCK FUNCTION (with PIN)
This menu option may be used to enable a LOCK function protected by a
numerical access code to prevent tampering (see page 12).
From the advanced menu, press
OK
repeatedly to view the following
screen:
To set the display lock only, set 000 as the PIN with the and keys.
To set the PIN-protected thermostat lock function (to prevent tampering),
set a PIN number between 001 and 999.
After enabling the lock function, from the main screen, press and hold
for 3 seconds to lock the display (see page 11), or press and hold for 3
seconds, enter the PIN set previously, then press
OK
to confirm to activate
the anti-tampering lock (see page 12).
Perform the same procedure to unlock.
NOTE
Enter the emergency unlock code 513 if you have forgotten the PIN.
After unlocking the unit with the emergency unlock code 513, it is strongly
recommended to access the advanced menu and check and/or modify the
user-defined PIN set previously.
29
7 - ENERGY SAVING E1
When the Energy Saving E1(ECO1) function is active, the thermostat
automatically optimises the operation of the system - specifically, using an
internal mathematical algorithm to compensate for inertia and adjust
activation intervals and temperature settings appropriately to improve
perceived comfort. This function also significantly reduces energy
consumption. Once in the advanced menu, press
OK
repeatedly to reach
the E1 function. Use the and buttons to select the following values
as desired.
E1 = 0 Function off
E1 = 1 Function on
E1 = 2 Function on if heating system is equipped with zone selector
valves with opening times greater than 10 seconds and less than
90 seconds
NOTE
This function is not recommended for forced ventilation heating systems
(e.g. fan coil).
8 - ENERGY SAVING E2
With the Energy Saving E2 (ECO2) function active, the thermostat determines
how long it takes the ambient air to reach the desired temperature.
This entirely automatic function adjusts the activation intervals, anticipating
and shortening activation times as necessary to save energy.
If activation times were set manually, in some cases it may be necessary to
anticipate/shorten activation times significantly to reach the desired
temperature at the desired time.
This function also takes the season, insulation and heat losses into account,
adjusting and shortening activation times accordingly. Example. If it takes
1.5 hours to increase the temperature by 4°C in January but only 40 minutes
in March, the ECO2 function will take this time into account.
ENERGY SAVING
NOTE
When the thermostat is automatically anticipating/shortening activation
times (relative to the programmed hour period), the symbol is displayed
in the main menu.
NOTE
When the E2 function is activated, the thermostat takes a few days to
monitor ambient conditions before the function is fully effective.
9 - DELAYED START
This function is used to delay start by 30 minutes after the programmed hour
period.
The following screen is displayed after the ENERGY SAVING E2 menu:
Press one of the two arrow keys to enable the function, and press
OK
to confirm.
To exit the advanced menu, press
OK
repeatedly or press
S
E
T
until the
unit sounds three beeps confirming that the modification has been saved.
The thermostat is now off.
Press to switch the thermostat on, and configure the settings as
indicated on page 22.
30
10 - RESET
Used to restore all the original factory settings.
Use the and keys to set .
Press
OK
to confirm. The thermostat switches off completely and then
restarts, displaying the software version and then the main screen.
The unit has now been reset and all factory settings have been restored.
NOTE
Resetting does not cancel the time and date.
31
33

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Finder 1C.81 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Finder 1C.81 in de taal/talen: Engels als bijlage per email.

De handleiding is 1,16 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Andere handleiding(en) van Finder 1C.81

Finder 1C.81 Gebruiksaanwijzing - Français - 40 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info