26
To step back in the menu press , while to exit, press the key for
3 seconds or press repeatedly until the message OFF appears on
the screen. If something has been changed, 3 beeps will confirm the
successful change.
4 - ANTI-SEIZE PUMP function
After programming the thermal differential, press to display the
following screen
(Anti-seize function OFF)
The anti-seize pump function is a function that will configure the thermostat
as an asymmetrical timer. By setting a value between 1 and 99 hours, the
thermostat will close the output contact for 30 seconds, every time the
set time value has elapsed.
Example:
By setting with keys or the value 48 (48 hours = 2 days) and
confirming with , the thermostat will close the relay contact for 30
seconds, every 2 days.
After enabling the function in the menu, the count will start after the last
switching off of the relay.
To step back in the menu press while to exit the Advanced Menu,
press and hold the for 3 seconds, or press repeatedly, until the
screen shows OFF.
If something has been changed, 3 beeps will confirm the successful
change.