Planer
Technical data HL 850 EB
Power 850 W
Speed (no load)
HL 850 EB 11000 rpm
Plane width 82 mm
Chip thickness 0 - 3.5 mm
Max. rebate depth unlimited
Weight (excluding cable) 3.9 kg
Degree of protection / II
The specifi ed illustrations can be found at the
beginning of the operating instructions.
Graphical symbols
Caution. Danger!
Read the operating instructions/notes
Wear ear protection!
Wear a protective mask!
1 Intended use
The tool together with the available Festool ac-
cessories is designed for processing wood, soft
plastics and similar materials.
The user is liable for damage and injury
resulting from incorrect usage!
2 Safety instructions
2.1 General Safety Rules
WARNING! Read all safety warnings and
all instructions. Failure to follow the warnings and
instructions may result in electric shock, fi re and/
or serious injury.
Save all warnings and instructions for future
reference.
The term „power tool“ in the warnings refers
to your mains-operated (corded) power tool or
battery-operated (cordless) power tool.
2.2 Tool-specifi c safety rules
- Wait for the cutter to stop before setting the
tool down. An exposed cutter may engage the
surface leading to possible loss of control and
serious injury.
- Hold the power tool by insulated gripping
surfaces only, because the cutter may contact
its own cord. Cutting a „live“ wire may make
exposed metal parts of the power tool „live“ and
could give the operator an electric shock.
- Use clamps or another practical way to secure
and support the workpiece to a stable platform.
Holding the work by your hand or against the
body leaves it unstable and may lead to loss of
control.
- Festool electric power tools should only be
installed in work benches specially designed
by Festool. The electric power tool may become
unsafe and cause serious accident if installed
in benches from other manufacturers or self-
manufactured work benches.
- Wear suitable personal protection equip-
ment:
Ear protection to reduce the risk
of damaging your hearing; Protec-
tive goggles; Face mask to reduce
the risk of inhaling harmful dust;
Protective gloves when handling
tools and coarse materials.
2.3 Noise and vibration information
The typical values determined in accordance with
EN 60745 are:
Sound-pressure level 80 dB(A)
Sound-power level 91 dB(A)
Measuring uncertainty allowance K = 3 dB
Wear ear protection!
Overall vibration levels (vector sum for three
directions) measured in accordance with EN
60745:
Vibration emission level (3 directions):
a
h
< 2.5 m/s²
Uncertainty K = 1,5 m/s²
The specifi ed emissions values (vibration, noise)
– are used to compare machines.
– They are also used for making preliminary
estimates regarding vibration and noise loads
during operation.
– They represent the primary applications of the
power tool.
Increase possible for other applications, with
other insertion tools or if not maintained adequat-
ely. Take note of idling and downtimes of machine!
3 Power supply and start-up
The mains voltage must correspond to
the specifi cation on the rating plate.
To switch on, fi rst press the switch lock (1.1)
and then the switch (1.2) (press = ON, release =
OFF).