67
7. Installation of electrical devices
Pin name Assignment Safeguarded Designation
S2 Earth from power supply
S1 12 V from power supply
S41 2 x earth and 2 x plus from battery 9/13
S38 Earth and plus to charging controller for rally package
S39 Earth and plus to charging controller for rally package
S40 Earth and plus 10/11 for rally package
A1 Earth and plus (water pump) 10 A fuse
A
A2 Earth and plus (Porta Potti toilet) 10 A fuse
A3 Earth and plus (12V, plug sockets) 10 A fuse
A4 Earth and plus 10 A fuse
B2 Earth and plus (antenna) 10 A fuse
B
B3 Earth and plus (combi heating or circulation fan) 10 A fuse
B4 Earth and plus (circulation fan) 10 A fuse
B5 Earth and plus + steady plus (radio) 10 A fuse
B6 Earth and steady plus (Wi-Fi) 10 A fuse
B7 Earth and steady plus (Tec-Tower) 10 A fuse
B8 Earth and steady plus 10 A fuse
C1 Earth and plus (lighting in living room) 5 A fuse
CC2 Earth and plus (lighting in kitchen) 5 A fuse
C3 Earth and plus 5 A fuse
D1 Earth and 2 x plus for ceiling light in bedroom 5 A fuse
D
D2a= plus upper LED strip overhead stowage compartment 5 A fuse
D2 D3a= plus lower LED strip overhead stowage compartment and lighting for corner shelf 5 A fuse
Earth and plus 5 A fuse
D2b Earth and plus LED strip 5 A fuse
D3b Earth and plus LED strip superstructure 5 A fuse
D5 Earth and plus 5 A fuse
E1 Earth and 2 x plus for ceiling lights in living room 7.5 A fuse
E
E2a = plus upper LED strip overhead stowage compartment 7.5 A fuse
E2 E3a= lower LED strip overhead stowage compartment and lighting for corner shelf 7.5 A fuse
Earth and plus 7.5 A fuse
E2b Earth and plus upper LED strip overhead stowage compartment 7.5 A fuse
E3b Earth and plus lower LED strip overhead stowage compartment and lighting for corner shelf 7.5 A fuse
E4 Earth and plus 7.5 A fuse
E5 Earth and plus LED strip for bar 7.5 A fuse
F1 Earth and plus outer tent light, LED lighting for step 7.5 A fuse
F
F2 Earth and plus awning rail lighting 7.5 A fuse
F3 Earth and plus downlighters 7.5 A fuse
F4 Earth and plus 7.5 A fuse
S46 Input 230 V phase and neutral
S35 Input 230 V boiler
S34 Output 230 V oor heating
PE1 Protective earth input 230 V
PE2 Protective earth output boiler
PE3 Protective earth output oor heating
PE4 Protective earth connector for connection to earth power supply low voltage
PE5 Connector earth power supply/devices for connection to protective earth
Control panel in bedrooms, keys 1,7,8,9,C
Control panel in bedroom keys 1,7,8,9,C
Control panel external lighting
Main panel
7x Ci-Bus
Pin assignment for the switch box